{"title":"Psychiatry Equipment","description":null,"products":[{"product_id":"medstim-rtms-machine-transcranial-magnetic-stimulator","title":"MedStim Repetitive Transcranial Magnetic Stimulation (rTMS) Machine","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMedStim Repetitive Transcranial Magnetic Stimulation (rTMS) Machine\u003c\/strong\u003e, available in \u003cstrong\u003eMS-30\u003c\/strong\u003e, \u003cstrong\u003eMS-50, and MS-100 models\u003c\/strong\u003e, is an advanced non-invasive neurostimulation system designed for clinical and research applications in \u003cstrong\u003epsychiatry, neurology, physiotherapy, and rehabilitation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eManufactured by \u003cstrong\u003eMedicaid Systems\u003c\/strong\u003e, the MedStim rTMS machine uses electromagnetic induction to deliver controlled magnetic pulses to targeted areas of the brain. Its \u003cstrong\u003ebi-phasic full-sine waveform\u003c\/strong\u003e, programmable stimulation parameters, integrated protocol storage, and high repetition rates make it suitable for a wide range of repetitive transcranial magnetic stimulation applications.\u003c\/p\u003e\n\u003cp\u003eDepending on the model, the system provides stimulation rates of up to \u003cstrong\u003e30 pps, 50 pps, or 100 pps\u003c\/strong\u003e, with \u003cstrong\u003eTheta Burst Protocol\u003c\/strong\u003e support available on the MS-50 and MS-100. The integrated computer interface allows operators to store and execute treatment protocols while monitoring stimulation parameters through the LCD display.\u003c\/p\u003e\n\u003cp\u003eThe system also incorporates important safety and usability features, including a \u003cstrong\u003e360° rotating coil stand, coil trigger controls, and coil temperature monitoring\u003c\/strong\u003e. Optional \u003cstrong\u003eMotor Evoked Potential (MEP) monitoring\u003c\/strong\u003e can be integrated for applications requiring measurement of evoked motor responses.\u003c\/p\u003e\n\u003cp\u003eMedStim rTMS is designed for professional clinical environments where controlled, repeatable, and non-invasive brain stimulation is required.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Bi-phasic Full-Sine Waveform:\u003c\/strong\u003e Delivers controlled biphasic magnetic stimulation with a pulse width of 320 µs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Model Options:\u003c\/strong\u003e Available in MS-30, MS-50, and MS-100 configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Repetition Rate:\u003c\/strong\u003e Supports up to 30 pps, 50 pps, or 100 pps depending on the selected model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Stimulation Modes:\u003c\/strong\u003e Supports single-pulse and repetitive stimulation, with burst functionality on the MS-100.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTheta Burst Protocol:\u003c\/strong\u003e Available with MS-50 and MS-100 models for specialized stimulation protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable Output Energy:\u003c\/strong\u003e Adjustable output energy from 30% to 100%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Computer System:\u003c\/strong\u003e Built-in computer facilitates protocol storage, parameter configuration, and execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLCD Display:\u003c\/strong\u003e Provides convenient visibility of stimulation parameters during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoil Trigger Button:\u003c\/strong\u003e Enables convenient stimulation control directly from the coil.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e360° Rotating Coil Stand:\u003c\/strong\u003e Provides flexibility in coil positioning during clinical procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoil Temperature Monitoring:\u003c\/strong\u003e Built-in temperature sensing helps protect the coil during repeated stimulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Temperature Protection:\u003c\/strong\u003e Stimulation can pause when the coil reaches approximately 40°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional MEP Monitoring:\u003c\/strong\u003e Supports Motor Evoked Potential recording with multiple responses displayed for latency and amplitude assessment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Invasive Stimulation:\u003c\/strong\u003e Uses electromagnetic induction without requiring surgical intervention.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClinical \u0026amp; Research Applications:\u003c\/strong\u003e Suitable for psychiatry, neurology, rehabilitation, physiotherapy, and neuroscience research.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eMS-30\u003c\/th\u003e\n\u003cth\u003eMS-50\u003c\/th\u003e\n\u003cth\u003eMS-100\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Type\u003c\/td\u003e\n\u003ctd\u003eBi-phasic Full Sine\u003c\/td\u003e\n\u003ctd\u003eBi-phasic Full Sine\u003c\/td\u003e\n\u003ctd\u003eBi-phasic Full Sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width\u003c\/td\u003e\n\u003ctd\u003e320 µs\u003c\/td\u003e\n\u003ctd\u003e320 µs\u003c\/td\u003e\n\u003ctd\u003e320 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Repetition Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 30 pps\u003c\/td\u003e\n\u003ctd\u003eUp to 50 pps\u003c\/td\u003e\n\u003ctd\u003eUp to 100 pps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStimulation Modes\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; Repetitive\u003c\/td\u003e\n\u003ctd\u003eSingle \u0026amp; Repetitive\u003c\/td\u003e\n\u003ctd\u003eSingle\/Standard, Repetitive \u0026amp; Burst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTheta Burst Protocol\u003c\/td\u003e\n\u003ctd\u003eNot Provided\u003c\/td\u003e\n\u003ctd\u003eProvided\u003c\/td\u003e\n\u003ctd\u003eProvided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Energy\u003c\/td\u003e\n\u003ctd\u003e30%–100%\u003c\/td\u003e\n\u003ctd\u003e30%–100%\u003c\/td\u003e\n\u003ctd\u003e30%–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Initial dB\/dt\u003c\/td\u003e\n\u003ctd\u003e36 kilo Tesla, coil surface*\u003c\/td\u003e\n\u003ctd\u003e36 kilo Tesla, coil surface*\u003c\/td\u003e\n\u003ctd\u003e36 kilo Tesla, coil surface*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V ±10%, 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e230 V ±10%, 50\/60 Hz\u003c\/td\u003e\n\u003ctd\u003e230 V ±10%, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e2200 VA; 3.5 kW peak rated\u003c\/td\u003e\n\u003ctd\u003e2200 VA; 3.5 kW peak rated\u003c\/td\u003e\n\u003ctd\u003e2200 VA; 3.5 kW peak rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby Power\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003ctd\u003e90 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Unit Weight\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Classification\u003c\/td\u003e\n\u003ctd\u003eType BF\u003c\/td\u003e\n\u003ctd\u003eType BF\u003c\/td\u003e\n\u003ctd\u003eType BF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Specification terminology should be confirmed against the latest manufacturer documentation before publication.\u003c\/p\u003e\n\u003ch2\u003eClinical Applications\u003c\/h2\u003e\n\u003ch3\u003ePsychiatry\u003c\/h3\u003e\n\u003cp\u003eMedStim rTMS systems may be used by qualified healthcare professionals in clinical protocols involving:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMajor Depressive Disorder (MDD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTreatment-Resistant Depression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBipolar Disorder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eObsessive-Compulsive Disorder (OCD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnxiety-related conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSchizophrenia-related applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eADHD-related research and clinical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBehavioural disorders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNeurology\u003c\/h3\u003e\n\u003cp\u003ePotential neurological applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStroke rehabilitation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eParkinson's disease-related applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeuropathic pain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMigraine-related applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTinnitus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDystonia\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWriter's cramp\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeurological rehabilitation and research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysiotherapy \u0026amp; Rehabilitation\u003c\/h3\u003e\n\u003cp\u003eThe system can also support professional neurorehabilitation applications involving:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eChronic pain management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeuromuscular rehabilitation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePost-stroke rehabilitation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeurophysiological assessment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor pathway research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhy Choose MedStim rTMS Machine?\u003c\/h2\u003e\n\u003cp\u003eThe MedStim rTMS platform combines \u003cstrong\u003ehigh-frequency repetitive stimulation, programmable treatment protocols, multiple stimulation modes, integrated computer control, coil safety monitoring, and optional MEP functionality\u003c\/strong\u003e in a compact clinical system.\u003c\/p\u003e\n\u003cp\u003eThe availability of three models allows healthcare facilities to select a configuration according to their stimulation-rate and protocol requirements. The MS-50 and MS-100 additionally provide Theta Burst Protocol functionality for facilities requiring more advanced stimulation capabilities\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e This product information is provided for general product guidance and marketing purposes. Clinical indications, treatment protocols, stimulation parameters, and approved uses may vary according to applicable regulations, manufacturer instructions, and clinical guidelines. The equipment should be operated only by appropriately trained healthcare professionals and strictly according to the manufacturer's instructions and applicable regulatory requirements. Specifications may vary by model, configuration, or production batch and should be confirmed with the manufacturer before purchase.\u003c\/p\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":52967125516469,"sku":"MEDICAID-RTMS","price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/medicaid-medstim-rtms-machine-health-yantra-store.jpg?v=1786622018"}],"url":"https:\/\/healthyantrastore.com\/collections\/psychiatry.oembed","provider":"Health Yantra Store","version":"1.0","type":"link"}