{"product_id":"aps-eto-sterilizer","title":"APS ETO Sterilizer","description":"\u003cp dir=\"auto\" data-start=\"22\" data-end=\"350\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"26\" data-end=\"48\"\u003eAPS ETO Sterilizer\u003c\/strong\u003e is a PLC-controlled ethylene oxide sterilization system designed for controlled low-temperature sterilization processes. The system is manufactured according to the supplied \u003cstrong data-start=\"223\" data-end=\"236\"\u003eGMP norms\u003c\/strong\u003e and provides automated control of critical process parameters including temperature, moisture, vacuum and valves.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"352\" data-end=\"581\"\u003eIt is available in chamber capacities ranging from \u003cstrong data-start=\"403\" data-end=\"430\"\u003e56 litres to 450 litres\u003c\/strong\u003e, with six pre-programmed cycles and additional user-defined cycles. An automatic aeration cycle is provided at the end of the process for ETO exhaust.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"583\" data-end=\"600\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"602\" data-end=\"1411\"\u003e\n\u003cli data-section-id=\"1ksngy3\" data-start=\"602\" data-end=\"637\"\u003eManufactured as per \u003cstrong data-start=\"624\" data-end=\"637\"\u003eGMP norms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l3b2qf\" data-start=\"638\" data-end=\"705\"\u003eAutomatic temperature control with \u003cstrong data-start=\"675\" data-end=\"683\"\u003e±3°C\u003c\/strong\u003e control specification\u003c\/li\u003e\n\u003cli data-section-id=\"qjra4r\" data-start=\"706\" data-end=\"792\"\u003eControl of temperature, moisture, vacuum valves and other stated critical parameters\u003c\/li\u003e\n\u003cli data-section-id=\"fx8yic\" data-start=\"793\" data-end=\"819\"\u003e\u003cstrong data-start=\"795\" data-end=\"819\"\u003ePLC-based automation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"letv5g\" data-start=\"820\" data-end=\"863\"\u003e\u003cstrong data-start=\"822\" data-end=\"863\"\u003e6 pre-programmed sterilization cycles\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"8wdfhr\" data-start=\"864\" data-end=\"896\"\u003eAdditional user-defined cycles\u003c\/li\u003e\n\u003cli data-section-id=\"xrj3p2\" data-start=\"897\" data-end=\"949\"\u003eAutomatic aeration cycle at the end of the process\u003c\/li\u003e\n\u003cli data-section-id=\"1mhxifv\" data-start=\"950\" data-end=\"1022\"\u003eDesigned to operate with universally available \u003cstrong data-start=\"999\" data-end=\"1022\"\u003e100% ETO cartridges\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1iolezh\" data-start=\"1023\" data-end=\"1061\"\u003eLive display of process phase status\u003c\/li\u003e\n\u003cli data-section-id=\"5kn5ep\" data-start=\"1062\" data-end=\"1102\"\u003eDisplays current values and set values\u003c\/li\u003e\n\u003cli data-section-id=\"u17f3n\" data-start=\"1103\" data-end=\"1152\"\u003eLive temperature, pressure and humidity display\u003c\/li\u003e\n\u003cli data-section-id=\"1vyytx9\" data-start=\"1153\" data-end=\"1198\"\u003eCurrent and previous reports can be printed\u003c\/li\u003e\n\u003cli data-section-id=\"10uy5gq\" data-start=\"1199\" data-end=\"1244\"\u003eExternal or internal printer options stated\u003c\/li\u003e\n\u003cli data-section-id=\"10fcybo\" data-start=\"1245\" data-end=\"1279\"\u003eHeavy-duty SS 304\/SS 316 chamber\u003c\/li\u003e\n\u003cli data-section-id=\"10e76x5\" data-start=\"1280\" data-end=\"1303\"\u003eGlass wool insulation\u003c\/li\u003e\n\u003cli data-section-id=\"1qe41ro\" data-start=\"1304\" data-end=\"1325\"\u003ePassword protection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1iskpyy\" dir=\"auto\" data-start=\"1418\" data-end=\"1440\"\u003ePLC-Based Automation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1442\" data-end=\"1537\"\u003eThe APS ETO Sterilizer uses \u003cstrong data-start=\"1470\" data-end=\"1494\"\u003ePLC-based automation\u003c\/strong\u003e for controlling the sterilization process.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1539\" data-end=\"1575\"\u003eThe supplied specification includes:\u003c\/p\u003e\n\u003cul data-start=\"1577\" data-end=\"1802\"\u003e\n\u003cli data-section-id=\"1sh8xv3\" data-start=\"1577\" data-end=\"1602\"\u003e6 pre-programmed cycles\u003c\/li\u003e\n\u003cli data-section-id=\"8wdfhr\" data-start=\"1603\" data-end=\"1635\"\u003eAdditional user-defined cycles\u003c\/li\u003e\n\u003cli data-section-id=\"156y68n\" data-start=\"1636\" data-end=\"1670\"\u003eAutomatic control of temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1lljz9d\" data-start=\"1671\" data-end=\"1689\"\u003eMoisture control\u003c\/li\u003e\n\u003cli data-section-id=\"1yjpij7\" data-start=\"1690\" data-end=\"1712\"\u003eVacuum-valve control\u003c\/li\u003e\n\u003cli data-section-id=\"15tbs4l\" data-start=\"1713\" data-end=\"1755\"\u003eOther stated critical process parameters\u003c\/li\u003e\n\u003cli data-section-id=\"ofzxfq\" data-start=\"1756\" data-end=\"1802\"\u003eAutomatic aeration at the end of the process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1804\" data-end=\"1881\"\u003eThis provides automated management of the programmed ETO sterilization cycle.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17kru4i\" dir=\"auto\" data-start=\"1883\" data-end=\"1906\"\u003eLive Process Display\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1908\" data-end=\"1980\"\u003eThe system provides a live display of sterilization-process information.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1982\" data-end=\"2042\"\u003eThe supplied specification states that the display can show:\u003c\/p\u003e\n\u003cul data-start=\"2044\" data-end=\"2132\"\u003e\n\u003cli data-section-id=\"8j69dh\" data-start=\"2044\" data-end=\"2066\"\u003eCurrent phase\/status\u003c\/li\u003e\n\u003cli data-section-id=\"1vc6q2h\" data-start=\"2067\" data-end=\"2083\"\u003eCurrent values\u003c\/li\u003e\n\u003cli data-section-id=\"16o1vo2\" data-start=\"2084\" data-end=\"2096\"\u003eSet values\u003c\/li\u003e\n\u003cli data-section-id=\"1f3vflw\" data-start=\"2097\" data-end=\"2110\"\u003eTemperature\u003c\/li\u003e\n\u003cli data-section-id=\"1od8urx\" data-start=\"2111\" data-end=\"2121\"\u003ePressure\u003c\/li\u003e\n\u003cli data-section-id=\"1h9cbht\" data-start=\"2122\" data-end=\"2132\"\u003eHumidity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2134\" data-end=\"2214\"\u003eThis allows operators to monitor the stated process parameters during operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"148snpv\" dir=\"auto\" data-start=\"2216\" data-end=\"2237\"\u003eAutomatic Aeration\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2239\" data-end=\"2325\"\u003eAn \u003cstrong data-start=\"2242\" data-end=\"2270\"\u003eautomatic aeration cycle\u003c\/strong\u003e is provided at the end of the process for ETO exhaust.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2327\" data-end=\"2418\"\u003eThis is an integrated part of the automated cycle described in the supplied specifications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"98r790\" dir=\"auto\" data-start=\"2512\" data-end=\"2537\"\u003eETO Cartridge Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2539\" data-end=\"2630\"\u003eThe sterilizer is designed to operate using a universally available \u003cstrong data-start=\"2607\" data-end=\"2629\"\u003e100% ETO cartridge\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2632\" data-end=\"2809\"\u003eA specific safety mechanism is provided whereby the \u003cstrong data-start=\"2684\" data-end=\"2767\"\u003eETO cartridge is punctured only under negative-pressure and humidity conditions\u003c\/strong\u003e, according to the supplied specification.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rpnxy7\" dir=\"auto\" data-start=\"2928\" data-end=\"2963\"\u003eChamber Construction \u0026amp; Insulation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2965\" data-end=\"3024\"\u003eThe chamber is fabricated using heavy-duty stainless steel:\u003c\/p\u003e\n\u003cul data-start=\"3026\" data-end=\"3051\"\u003e\n\u003cli data-section-id=\"w2np5r\" data-start=\"3026\" data-end=\"3038\"\u003e\u003cstrong data-start=\"3028\" data-end=\"3038\"\u003eSS 304\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"w2odoc\" data-start=\"3039\" data-end=\"3051\"\u003e\u003cstrong data-start=\"3041\" data-end=\"3051\"\u003eSS 316\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3112\" data-end=\"3186\"\u003e\u003cstrong data-start=\"3112\" data-end=\"3137\"\u003eGlass wool insulation\u003c\/strong\u003e is provided as part of the chamber construction.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ohxd2x\" dir=\"auto\" data-start=\"3188\" data-end=\"3210\"\u003ePassword Protection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3212\" data-end=\"3317\"\u003ePassword protection is incorporated to help prevent \u003cstrong data-start=\"3264\" data-end=\"3287\"\u003eunauthorized access\u003c\/strong\u003e to the sterilizer's controls.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5hpi3j\" dir=\"auto\" data-start=\"3324\" data-end=\"3346\"\u003eReporting \u0026amp; Printing\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3348\" data-end=\"3404\"\u003eThe APS ETO Sterilizer supports process-report printing.\u003c\/p\u003e\n\u003cul data-start=\"3446\" data-end=\"3582\"\u003e\n\u003cli data-section-id=\"1mealk7\" data-start=\"3446\" data-end=\"3478\"\u003eCurrent reports can be printed\u003c\/li\u003e\n\u003cli data-section-id=\"10jgjkv\" data-start=\"3479\" data-end=\"3512\"\u003ePrevious reports can be printed\u003c\/li\u003e\n\u003cli data-section-id=\"6sx6in\" data-start=\"3513\" data-end=\"3543\"\u003eExternal printer can be used\u003c\/li\u003e\n\u003cli data-section-id=\"4lu6cp\" data-start=\"3544\" data-end=\"3582\"\u003eInternal printer option is available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"l7p3ua\" dir=\"auto\" data-start=\"3650\" data-end=\"3684\"\u003eModel \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3686\" data-end=\"4007\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3686\" data-end=\"3725\"\u003e\n\u003ctr data-start=\"3686\" data-end=\"3725\"\u003e\n\u003cth data-start=\"3686\" data-end=\"3694\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"3694\" data-end=\"3703\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eVolume\u003c\/th\u003e\n\u003cth data-start=\"3703\" data-end=\"3725\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eInternal Dimension\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3742\" data-end=\"4007\"\u003e\n\u003ctr data-start=\"3742\" data-end=\"3784\"\u003e\n\u003ctd data-start=\"3742\" data-end=\"3758\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3744\" data-end=\"3757\"\u003eAP-ETO-56\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3758\" data-end=\"3765\" data-col-size=\"sm\"\u003e56 L\u003c\/td\u003e\n\u003ctd data-start=\"3765\" data-end=\"3784\" data-col-size=\"sm\"\u003e12 × 12 × 24 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3785\" data-end=\"3827\"\u003e\n\u003ctd data-start=\"3785\" data-end=\"3801\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3787\" data-end=\"3800\"\u003eAP-ETO-85\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3801\" data-end=\"3808\" data-col-size=\"sm\"\u003e85 L\u003c\/td\u003e\n\u003ctd data-start=\"3808\" data-end=\"3827\" data-col-size=\"sm\"\u003e12 × 12 × 36 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3828\" data-end=\"3872\"\u003e\n\u003ctd data-start=\"3828\" data-end=\"3845\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3830\" data-end=\"3844\"\u003eAP-ETO-110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3845\" data-end=\"3853\" data-col-size=\"sm\"\u003e110 L\u003c\/td\u003e\n\u003ctd data-start=\"3853\" data-end=\"3872\" data-col-size=\"sm\"\u003e12 × 12 × 48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3873\" data-end=\"3917\"\u003e\n\u003ctd data-start=\"3873\" data-end=\"3890\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3875\" data-end=\"3889\"\u003eAP-ETO-190\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3890\" data-end=\"3898\" data-col-size=\"sm\"\u003e190 L\u003c\/td\u003e\n\u003ctd data-start=\"3898\" data-end=\"3917\" data-col-size=\"sm\"\u003e18 × 18 × 36 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3918\" data-end=\"3962\"\u003e\n\u003ctd data-start=\"3918\" data-end=\"3935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3920\" data-end=\"3934\"\u003eAP-ETO-256\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3935\" data-end=\"3943\" data-col-size=\"sm\"\u003e256 L\u003c\/td\u003e\n\u003ctd data-start=\"3943\" data-end=\"3962\" data-col-size=\"sm\"\u003e18 × 18 × 48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3963\" data-end=\"4007\"\u003e\n\u003ctd data-start=\"3963\" data-end=\"3980\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3965\" data-end=\"3979\"\u003eAP-ETO-450\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3980\" data-end=\"3988\" data-col-size=\"sm\"\u003e450 L\u003c\/td\u003e\n\u003ctd data-start=\"3988\" data-end=\"4007\" data-col-size=\"sm\"\u003e24 × 24 × 48 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"hz34la\" dir=\"auto\" data-start=\"4009\" data-end=\"4035\"\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-section-id=\"hz34la\" dir=\"auto\" data-start=\"4009\" data-end=\"4035\"\u003eGeneral Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4037\" data-end=\"4869\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100.058%;\"\u003e\n\u003cthead data-start=\"4037\" data-end=\"4064\"\u003e\n\u003ctr data-start=\"4037\" data-end=\"4064\"\u003e\n\u003cth data-start=\"4037\" data-end=\"4053\" data-col-size=\"sm\" class=\"last:pe-10\" style=\"width: 25.8892%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4053\" data-end=\"4064\" data-col-size=\"md\" class=\"last:pe-10\" style=\"width: 73.6443%;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4075\" data-end=\"4869\"\u003e\n\u003ctr data-start=\"4075\" data-end=\"4108\"\u003e\n\u003ctd data-start=\"4075\" data-end=\"4090\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"4090\" data-end=\"4108\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eETO Sterilizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4109\" data-end=\"4153\"\u003e\n\u003ctd data-start=\"4109\" data-end=\"4131\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eSterilization Agent\u003c\/td\u003e\n\u003ctd data-start=\"4131\" data-end=\"4153\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003e100% ETO cartridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4154\" data-end=\"4205\"\u003e\n\u003ctd data-start=\"4154\" data-end=\"4179\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eManufacturing Standard\u003c\/td\u003e\n\u003ctd data-start=\"4179\" data-end=\"4205\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eGMP norms, as supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4206\" data-end=\"4232\"\u003e\n\u003ctd data-start=\"4206\" data-end=\"4219\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eAutomation\u003c\/td\u003e\n\u003ctd data-start=\"4219\" data-end=\"4232\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003ePLC based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4233\" data-end=\"4262\"\u003e\n\u003ctd data-start=\"4233\" data-end=\"4257\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003ePre-Programmed Cycles\u003c\/td\u003e\n\u003ctd data-start=\"4257\" data-end=\"4262\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4263\" data-end=\"4298\"\u003e\n\u003ctd data-start=\"4263\" data-end=\"4285\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eUser-Defined Cycles\u003c\/td\u003e\n\u003ctd data-start=\"4285\" data-end=\"4298\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4299\" data-end=\"4340\"\u003e\n\u003ctd data-start=\"4299\" data-end=\"4321\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eTemperature Control\u003c\/td\u003e\n\u003ctd data-start=\"4321\" data-end=\"4340\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eAutomatic, ±3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4341\" data-end=\"4433\"\u003e\n\u003ctd data-start=\"4341\" data-end=\"4362\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eProcess Parameters\u003c\/td\u003e\n\u003ctd data-start=\"4362\" data-end=\"4433\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eTemperature, moisture, vacuum valves and stated critical parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4434\" data-end=\"4476\"\u003e\n\u003ctd data-start=\"4434\" data-end=\"4445\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eAeration\u003c\/td\u003e\n\u003ctd data-start=\"4445\" data-end=\"4476\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eAutomatic at end of process\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4477\" data-end=\"4559\"\u003e\n\u003ctd data-start=\"4477\" data-end=\"4487\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"4487\" data-end=\"4559\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003ePhase status, current\/set values, temperature, pressure and humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4560\" data-end=\"4604\"\u003e\n\u003ctd data-start=\"4560\" data-end=\"4572\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eReporting\u003c\/td\u003e\n\u003ctd data-start=\"4572\" data-end=\"4604\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eCurrent and previous reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4605\" data-end=\"4655\"\u003e\n\u003ctd data-start=\"4605\" data-end=\"4616\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003ePrinting\u003c\/td\u003e\n\u003ctd data-start=\"4616\" data-end=\"4655\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eExternal printer \/ internal printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4656\" data-end=\"4705\"\u003e\n\u003ctd data-start=\"4656\" data-end=\"4675\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eChamber Material\u003c\/td\u003e\n\u003ctd data-start=\"4675\" data-end=\"4705\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eHeavy-duty SS 304 \/ SS 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4706\" data-end=\"4733\"\u003e\n\u003ctd data-start=\"4706\" data-end=\"4719\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"4719\" data-end=\"4733\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003eGlass wool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4734\" data-end=\"4777\"\u003e\n\u003ctd data-start=\"4734\" data-end=\"4754\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eAccess Protection\u003c\/td\u003e\n\u003ctd data-start=\"4754\" data-end=\"4777\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003ePassword protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4778\" data-end=\"4869\"\u003e\n\u003ctd data-start=\"4778\" data-end=\"4797\" data-col-size=\"sm\" style=\"width: 25.8892%;\"\u003eCartridge Safety\u003c\/td\u003e\n\u003ctd data-start=\"4797\" data-end=\"4869\" data-col-size=\"md\" style=\"width: 73.6443%;\"\u003ePuncturing under specified negative-pressure and humidity conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"APS","offers":[{"title":"Default Title","offer_id":53402658898101,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/APS-ETO-Sterilizer-56L_450L-Ethylene-Oxide-Sterilizer.jpg?v=1790747579","url":"https:\/\/healthyantrastore.com\/products\/aps-eto-sterilizer","provider":"Health Yantra Store","version":"1.0","type":"link"}