{"product_id":"aps-table-top-autoclave-b-type-flash-autoclave","title":"APS Table Top Autoclave (B-Type) \/ Flash Autoclave","description":"\u003cp dir=\"auto\" data-start=\"54\" data-end=\"377\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"58\" data-end=\"94\"\u003eAPS Table Top Autoclave (B-Type)\u003c\/strong\u003e is a \u003cstrong data-start=\"100\" data-end=\"149\"\u003efront-load, fully automatic Class B autoclave\u003c\/strong\u003e designed for efficient steam sterilization using \u003cstrong data-start=\"199\" data-end=\"234\"\u003epre- and post-vacuum technology\u003c\/strong\u003e. The integrated vacuum pump assists with air removal from the chamber, supporting sterilization of a broad range of instruments and materials.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"379\" data-end=\"606\"\u003eThe standard model \u003cstrong data-start=\"398\" data-end=\"412\"\u003eAPS-TTA21B\u003c\/strong\u003e has a \u003cstrong data-start=\"419\" data-end=\"440\"\u003e21-litre capacity\u003c\/strong\u003e and features a full stainless-steel construction, automatic controls, digital temperature display, programmable operation, integrated drier, vacuum pump and printer.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"608\" data-end=\"722\"\u003eAccording to the supplied product information, the unit supports sterilization of \u003cstrong data-start=\"690\" data-end=\"721\"\u003ewrapped and unwrapped items\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"724\" data-end=\"741\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"743\" data-end=\"1536\"\u003e\n\u003cli data-section-id=\"xciwff\" data-start=\"743\" data-end=\"776\"\u003e\u003cstrong data-start=\"745\" data-end=\"776\"\u003eClass B automatic autoclave\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"i4keg2\" data-start=\"777\" data-end=\"795\"\u003eTable-top design\u003c\/li\u003e\n\u003cli data-section-id=\"1w3pf3m\" data-start=\"796\" data-end=\"822\"\u003eFront-load configuration\u003c\/li\u003e\n\u003cli data-section-id=\"1d7jbmy\" data-start=\"823\" data-end=\"850\"\u003eFully automatic operation\u003c\/li\u003e\n\u003cli data-section-id=\"1op0wlf\" data-start=\"851\" data-end=\"884\"\u003ePre- and post-vacuum technology\u003c\/li\u003e\n\u003cli data-section-id=\"teal69\" data-start=\"885\" data-end=\"925\"\u003eIntegrated vacuum pump for air removal\u003c\/li\u003e\n\u003cli data-section-id=\"1s919v8\" data-start=\"926\" data-end=\"968\"\u003eSuitable for wrapped and unwrapped items\u003c\/li\u003e\n\u003cli data-section-id=\"gjp9hu\" data-start=\"969\" data-end=\"1028\"\u003eDesigned for different types of instruments and materials\u003c\/li\u003e\n\u003cli data-section-id=\"1acp57s\" data-start=\"1029\" data-end=\"1064\"\u003eFull stainless-steel construction\u003c\/li\u003e\n\u003cli data-section-id=\"9o6gv8\" data-start=\"1065\" data-end=\"1094\"\u003eDigital temperature display\u003c\/li\u003e\n\u003cli data-section-id=\"1mykfmq\" data-start=\"1095\" data-end=\"1124\"\u003eUser-friendly control panel\u003c\/li\u003e\n\u003cli data-section-id=\"1a1mkqd\" data-start=\"1125\" data-end=\"1163\"\u003eProgrammable sterilization operation\u003c\/li\u003e\n\u003cli data-section-id=\"hxck8n\" data-start=\"1164\" data-end=\"1182\"\u003eIntegrated drier\u003c\/li\u003e\n\u003cli data-section-id=\"15p9698\" data-start=\"1183\" data-end=\"1224\"\u003eImported \u003cstrong data-start=\"1194\" data-end=\"1224\"\u003eItaly Sirai solenoid valve\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"kx6d0k\" data-start=\"1225\" data-end=\"1248\"\u003eEasy-to-clean gaskets\u003c\/li\u003e\n\u003cli data-section-id=\"v2fttl\" data-start=\"1249\" data-end=\"1277\"\u003eEasily replaceable gaskets\u003c\/li\u003e\n\u003cli data-section-id=\"1dcgyg1\" data-start=\"1278\" data-end=\"1310\"\u003eTemperature selection facility\u003c\/li\u003e\n\u003cli data-section-id=\"1ee3x1o\" data-start=\"1311\" data-end=\"1357\"\u003eTemperature deviation of \u003cstrong data-start=\"1338\" data-end=\"1357\"\u003eless than 0.5°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3xwp29\" data-start=\"1358\" data-end=\"1387\"\u003eHigh-power heating elements\u003c\/li\u003e\n\u003cli data-section-id=\"wsgstr\" data-start=\"1388\" data-end=\"1435\"\u003eTwo working temperatures: \u003cstrong data-start=\"1416\" data-end=\"1435\"\u003e121°C and 134°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14lgj36\" data-start=\"1436\" data-end=\"1484\"\u003eTwo working pressures: \u003cstrong data-start=\"1461\" data-end=\"1484\"\u003e1.2 bar and 2.1 bar\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jo8sa1\" data-start=\"1485\" data-end=\"1498\"\u003eVacuum pump\u003c\/li\u003e\n\u003cli data-section-id=\"n4cg7i\" data-start=\"1499\" data-end=\"1508\"\u003ePrinter\u003c\/li\u003e\n\u003cli data-section-id=\"1jih22u\" data-start=\"1509\" data-end=\"1536\"\u003e21-litre chamber capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1f4ed3j\" dir=\"auto\" data-start=\"1538\" data-end=\"1578\"\u003eClass B Pre- \u0026amp; Post-Vacuum Technology\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1580\" data-end=\"1747\"\u003eThe APS B-Type autoclave operates using \u003cstrong data-start=\"1620\" data-end=\"1655\"\u003epre- and post-vacuum technology\u003c\/strong\u003e. A vacuum pump is integrated into the unit to assist with air removal before sterilization.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1749\" data-end=\"1920\"\u003eThe supplied product information describes the system as suitable for sterilizing \u003cstrong data-start=\"1831\" data-end=\"1862\"\u003ewrapped and unwrapped items\u003c\/strong\u003e, as well as different types of instruments and materials.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1g2lupz\" dir=\"auto\" data-start=\"1922\" data-end=\"1950\"\u003eFully Automatic Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1952\" data-end=\"2151\"\u003eThe APS-TTA21B features \u003cstrong data-start=\"1976\" data-end=\"2002\"\u003efull automatic control\u003c\/strong\u003e with a user-friendly control panel. Digital temperature visualization allows the operator to monitor the temperature during the sterilization cycle.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13i4ga8\" dir=\"auto\" data-start=\"2153\" data-end=\"2192\"\u003eSelectable Sterilization Temperature\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2194\" data-end=\"2252\"\u003eThe autoclave provides two specified working temperatures:\u003c\/p\u003e\n\u003cul data-start=\"2254\" data-end=\"2277\"\u003e\n\u003cli data-section-id=\"bkbew9\" data-start=\"2254\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2256\" data-end=\"2265\"\u003e121°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"c2vy4t\" data-start=\"2266\" data-end=\"2277\"\u003e\u003cstrong data-start=\"2268\" data-end=\"2277\"\u003e134°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2279\" data-end=\"2420\"\u003eThe temperature selection facility allows the operator to select the appropriate available cycle according to the sterilization requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1eynukh\" dir=\"auto\" data-start=\"2422\" data-end=\"2441\"\u003eWorking Pressure\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2443\" data-end=\"2485\"\u003eTwo working pressure levels are specified:\u003c\/p\u003e\n\u003cul data-start=\"2487\" data-end=\"2514\"\u003e\n\u003cli data-section-id=\"1nh8v1w\" data-start=\"2487\" data-end=\"2500\"\u003e\u003cstrong data-start=\"2489\" data-end=\"2500\"\u003e1.2 bar\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"14ai5v8\" data-start=\"2501\" data-end=\"2514\"\u003e\u003cstrong data-start=\"2503\" data-end=\"2514\"\u003e2.1 bar\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15pfk5l\" dir=\"auto\" data-start=\"2516\" data-end=\"2546\"\u003eDigital Temperature Display\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2548\" data-end=\"2728\"\u003eThe digital display provides easy visualization of the temperature during the sterilization cycle. The supplied specification states a temperature deviation of \u003cstrong data-start=\"2708\" data-end=\"2727\"\u003eless than 0.5°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hg9elg\" dir=\"auto\" data-start=\"2730\" data-end=\"2744\"\u003eVacuum Pump\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2746\" data-end=\"2928\"\u003eAn integrated \u003cstrong data-start=\"2760\" data-end=\"2775\"\u003evacuum pump\u003c\/strong\u003e is included for the pre- and post-vacuum process. The supplied description identifies air removal as a key function of the Class B sterilization system.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1sybli2\" dir=\"auto\" data-start=\"2930\" data-end=\"2949\"\u003eIntegrated Drier\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2951\" data-end=\"3099\"\u003eThe APS-TTA21B is described as a \u003cstrong data-start=\"2984\" data-end=\"3035\"\u003efront-loading programmable autoclave with drier\u003c\/strong\u003e, combining sterilization and drying functions in the same unit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"j0p7qs\" dir=\"auto\" data-start=\"3101\" data-end=\"3124\"\u003eSirai Solenoid Valve\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3126\" data-end=\"3316\"\u003eThe unit incorporates an \u003cstrong data-start=\"3151\" data-end=\"3181\"\u003eimported Italy Sirai valve\u003c\/strong\u003e, described in the supplied information as a specialized solenoid valve for proper maintenance of steam during the sterilization cycle.\u003c\/p\u003e\n\u003ch3 data-section-id=\"epm1x2\" dir=\"auto\" data-start=\"3318\" data-end=\"3349\"\u003eStainless-Steel Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3351\" data-end=\"3510\"\u003eThe supplied product information specifies \u003cstrong data-start=\"3394\" data-end=\"3431\"\u003efull stainless-steel construction\u003c\/strong\u003e, providing a durable material platform for the autoclave chamber and exterior.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rsy914\" dir=\"auto\" data-start=\"3512\" data-end=\"3528\"\u003eGasket Design\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3530\" data-end=\"3561\"\u003eThe gaskets are designed to be:\u003c\/p\u003e\n\u003cul data-start=\"3563\" data-end=\"3612\"\u003e\n\u003cli data-section-id=\"1be6o60\" data-start=\"3563\" data-end=\"3578\"\u003eEasy to clean\u003c\/li\u003e\n\u003cli data-section-id=\"kgt4im\" data-start=\"3579\" data-end=\"3612\"\u003eEasily replaceable when damaged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3614\" data-end=\"3672\"\u003eThis simplifies routine maintenance of the sealing system.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zjxypn\" dir=\"auto\" data-start=\"3679\" data-end=\"3705\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3707\" data-end=\"4513\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3707\" data-end=\"3744\"\u003e\n\u003ctr data-start=\"3707\" data-end=\"3744\"\u003e\n\u003cth data-start=\"3707\" data-end=\"3723\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3723\" data-end=\"3744\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3755\" data-end=\"4513\"\u003e\n\u003ctr data-start=\"3755\" data-end=\"3810\"\u003e\n\u003ctd data-start=\"3755\" data-end=\"3774\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3757\" data-end=\"3773\"\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3774\" data-end=\"3810\" data-col-size=\"sm\"\u003eAPS Table Top Autoclave (B-Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3811\" data-end=\"3853\"\u003e\n\u003ctd data-start=\"3811\" data-end=\"3822\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3813\" data-end=\"3821\"\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3822\" data-end=\"3853\" data-col-size=\"sm\"\u003eClass B Automatic Autoclave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3854\" data-end=\"3880\"\u003e\n\u003ctd data-start=\"3854\" data-end=\"3866\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3856\" data-end=\"3865\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3866\" data-end=\"3880\" data-col-size=\"sm\"\u003eAPS-TTA21B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3881\" data-end=\"3909\"\u003e\n\u003ctd data-start=\"3881\" data-end=\"3895\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3883\" data-end=\"3894\"\u003eLoading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3895\" data-end=\"3909\" data-col-size=\"sm\"\u003eFront Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3910\" data-end=\"3945\"\u003e\n\u003ctd data-start=\"3910\" data-end=\"3926\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3912\" data-end=\"3925\"\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3926\" data-end=\"3945\" data-col-size=\"sm\"\u003eFully Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3946\" data-end=\"3987\"\u003e\n\u003ctd data-start=\"3946\" data-end=\"3963\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3948\" data-end=\"3962\"\u003eTechnology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3963\" data-end=\"3987\" data-col-size=\"sm\"\u003ePre- and Post-Vacuum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3988\" data-end=\"4018\"\u003e\n\u003ctd data-start=\"3988\" data-end=\"4006\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3990\" data-end=\"4005\"\u003eVacuum Pump\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4006\" data-end=\"4018\" data-col-size=\"sm\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4019\" data-end=\"4047\"\u003e\n\u003ctd data-start=\"4019\" data-end=\"4034\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4021\" data-end=\"4033\"\u003eCapacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4034\" data-end=\"4047\" data-col-size=\"sm\"\u003e21 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4048\" data-end=\"4091\"\u003e\n\u003ctd data-start=\"4048\" data-end=\"4067\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4050\" data-end=\"4066\"\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4067\" data-end=\"4091\" data-col-size=\"sm\"\u003eFull Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4092\" data-end=\"4135\"\u003e\n\u003ctd data-start=\"4092\" data-end=\"4118\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4094\" data-end=\"4117\"\u003eWorking Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4118\" data-end=\"4135\" data-col-size=\"sm\"\u003e121°C \/ 134°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4136\" data-end=\"4180\"\u003e\n\u003ctd data-start=\"4136\" data-end=\"4159\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4138\" data-end=\"4158\"\u003eWorking Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4159\" data-end=\"4180\" data-col-size=\"sm\"\u003e1.2 bar \/ 2.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4181\" data-end=\"4219\"\u003e\n\u003ctd data-start=\"4181\" data-end=\"4209\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4183\" data-end=\"4208\"\u003eTemperature Deviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4209\" data-end=\"4219\" data-col-size=\"sm\"\u003e\u0026lt;0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4220\" data-end=\"4253\"\u003e\n\u003ctd data-start=\"4220\" data-end=\"4233\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4222\" data-end=\"4232\"\u003eDrying\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4233\" data-end=\"4253\" data-col-size=\"sm\"\u003eIntegrated Drier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4254\" data-end=\"4291\"\u003e\n\u003ctd data-start=\"4254\" data-end=\"4280\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4256\" data-end=\"4279\"\u003eTemperature Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4280\" data-end=\"4291\" data-col-size=\"sm\"\u003eDigital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4292\" data-end=\"4329\"\u003e\n\u003ctd data-start=\"4292\" data-end=\"4312\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4294\" data-end=\"4311\"\u003eControl Panel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4312\" data-end=\"4329\" data-col-size=\"sm\"\u003eUser-Friendly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4330\" data-end=\"4381\"\u003e\n\u003ctd data-start=\"4330\" data-end=\"4342\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4332\" data-end=\"4341\"\u003eValve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4342\" data-end=\"4381\" data-col-size=\"sm\"\u003eImported Italy Sirai Solenoid Valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4382\" data-end=\"4426\"\u003e\n\u003ctd data-start=\"4382\" data-end=\"4395\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4384\" data-end=\"4394\"\u003eGasket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4395\" data-end=\"4426\" data-col-size=\"sm\"\u003eEasy to Clean \u0026amp; Replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4427\" data-end=\"4453\"\u003e\n\u003ctd data-start=\"4427\" data-end=\"4441\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4429\" data-end=\"4440\"\u003ePrinter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4441\" data-end=\"4453\" data-col-size=\"sm\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4454\" data-end=\"4476\"\u003e\n\u003ctd data-start=\"4454\" data-end=\"4467\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4456\" data-end=\"4466\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4467\" data-end=\"4476\" data-col-size=\"sm\"\u003e20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4477\" data-end=\"4513\"\u003e\n\u003ctd data-start=\"4477\" data-end=\"4494\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4479\" data-end=\"4493\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4494\" data-end=\"4513\" data-col-size=\"sm\"\u003e20 × 20 × 20 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"APS","offers":[{"title":"Default Title","offer_id":53397028143285,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/APS-Table-Top-B-Type-Autoclave-21L-Class-B-Vacuum-_-Dryer.jpg?v=1790666842","url":"https:\/\/healthyantrastore.com\/products\/aps-table-top-autoclave-b-type-flash-autoclave","provider":"Health Yantra Store","version":"1.0","type":"link"}