{"product_id":"beacon-beaconic-b200-fully-automatic-biochemistry-analyzer","title":"Beacon Beaconic B200 Fully Automatic Biochemistry Analyzer","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe \u003cstrong\u003eBeacon Beaconic B200\u003c\/strong\u003e is a fully automatic, random-access biochemistry analyzer designed for medium to large laboratories. It performs a wide range of biochemical tests on serum, plasma, urine, and other liquid samples. The system reduces manual work, gives fast and accurate results, and offers stable performance with low operating cost.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Highlights\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFully automatic random-access operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 200 tests per hour\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLow minimum sample volume helps reduce sample wastage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic cuvette washing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProbe with liquid-level detection and collision protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports end point, kinetic, fixed-time, and turbidimetric methods\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact footprint suitable for mid-high workload labs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStable performance with minimal maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEasy software operation suitable for all skill levels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTest Menu\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLiver Function Tests (SGOT, SGPT, ALP, Bilirubin, etc.)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eKidney Function Tests (Urea, Creatinine, Uric Acid)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLipid Profile (Cholesterol, HDL-C, LDL-C, Triglycerides)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCardiac Profile tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrolyte tests (if reagents available)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnzyme assays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtein tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGlucose tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCalcium, Magnesium, Phosphorus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCRP, ASO, RF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMany other routine and special chemistry assays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.058%; height: 666.189px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eMachine Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eRandom access\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eTest Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eConstant 200 tests\/hour (mono reagent or double reagent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eTest Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eColorimetric method, turbidimetry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eTest Methods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e1-point end, 2-point end, fixed-time, kinetics\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eCalibrator Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eLinear \u0026amp; nonlinear\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReagent Tray\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e40 reagent positions (40 for R1 \u0026amp; R2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eCooling System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eNon-stop cooling with internal Peltier pad (24 hours, 8°C–14°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReagent Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e10–300 µL (1 µL step)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReaction Tray\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e44 single reaction Pyrex cuvettes with perfect transmittance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReaction Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e150–330 µL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReaction Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eSolid-state heating, 37°C ± 0.1°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eSample Tray Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e40 sample positions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 39.1875px;\"\u003e\u003cspan\u003eCompatible Sample Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 39.1875px;\"\u003e\u003cspan\u003eMicro cup, primary tube, blood collection tube (Ø 12–13 mm × 25–100 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eSample Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e2–30 µL (0.1 µL step)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 39.1875px;\"\u003e\u003cspan\u003eSample Probe Features\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 39.1875px;\"\u003e\u003cspan\u003eLiquid surface detection, real-time volume tracking, vertical collision protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eMixer Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003ePaddle-type mixer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eEffective mixing, reduced carryover\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eLight Source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eHalogen lamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 39.1875px;\"\u003e\u003cspan\u003eWavelengths\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 39.1875px;\"\u003e\u003cspan\u003e340, 405, 450, 505, 546, 578, 630, 700 nm (with 4 additional optional wavelengths)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eWindows 10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eReport Printing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e6 selectable formats + custom format support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003ePattern interface, TCP\/IP network interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eWater Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eMaximum 8 L\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e78 cm × 56.5 cm × 112 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e80 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003e220V ± 10%, 50\/60 Hz, 1000 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.5394%; height: 19.5938px;\"\u003e\u003cspan\u003eUPS Requirement\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74.1691%; height: 19.5938px;\"\u003e\u003cspan\u003eOnline UPS (230V) with 2 KVA isolated transformer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Disclaimer\u003c\/h2\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Beacon Diagnostics","offers":[{"title":"Default Title","offer_id":53592403312821,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Beacon-Beaconi-B200-Fully-Automatic-Biochemistry-Analyzer.jpg?v=1792758932","url":"https:\/\/healthyantrastore.com\/products\/beacon-beaconic-b200-fully-automatic-biochemistry-analyzer","provider":"Health Yantra Store","version":"1.0","type":"link"}