{"product_id":"biotronix-hnc-cold-laser-therapy-machine-650nm-red-808nm-infrared-lllt-device","title":"Biotronix HNC Cold Laser Therapy Machine – 650nm Red \u0026 808nm Infrared LLLT Device","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBiotronix HNC Low Level Cold Laser Therapy Device\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a dual-wavelength low-level laser therapy (LLLT) unit designed for selected physiotherapy, rehabilitation and pain-management applications. It combines 650nm visible red laser and 808nm infrared laser wavelengths in a non-invasive treatment system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe device uses \u003cstrong\u003eGaAlAs semiconductor laser technology \u003c\/strong\u003eand offers adjustable treatment controls, including session timing and intensity or pulse settings, depending on the supplied configuration. It may be incorporated into professionally guided rehabilitation programmes where low-level laser therapy is considered appropriate.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDual-Wavelength Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Combines 650nm visible red and 808nm invisible infrared laser wavelengths.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eGaAlAs Semiconductor Laser:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses gallium aluminium arsenide semiconductor laser technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eLow-Level Laser Therapy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for non-invasive photobiomodulation applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAdjustable Treatment Controls:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Offers session timer and intensity or pulse settings, depending on the model configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProbe Configurations:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available configurations may include multi-beam probes or diode arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePhysiotherapy Applications:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intended for selected rehabilitation and musculoskeletal therapy applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eClinic and Professional Use:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be incorporated into treatment programmes under appropriate professional guidance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDual-Wavelength Laser Technology\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e650nm Red Laser\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 650nm wavelength produces visible red laser light. It is one of the wavelengths used in low-level laser therapy systems for selected photobiomodulation applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003e808nm Infrared Laser\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe 808nm wavelength produces invisible near-infrared laser light. It is used in selected low-level laser therapy applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe combination of red and infrared wavelengths provides two laser wavelength options within one device. Actual treatment characteristics depend on the probe configuration, optical output, treatment distance and application protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWuhan HNC Technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHNC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDevice Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Level Cold Laser Therapy Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTherapy Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLow-Level Laser Therapy (LLLT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLaser Medium\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGaAlAs semiconductor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWavelength 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650nm visible red\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWavelength 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e808nm invisible infrared\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLaser Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-beam probe or diode-array configurations may vary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e650nm Diode Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5mW per diode in certain described configurations; confirm exact model\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e808nm Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVaries by probe and model configuration; confirm before purchase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTreatment Controls\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable timer and intensity\/pulse settings, depending on configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePenetration Depth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA 3–5cm figure is sometimes quoted; actual effective optical penetration varies with tissue and measurement method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Disclaimer\u003c\/h2\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Biotronix Care International","offers":[{"title":"Default Title","offer_id":53827319333045,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Biotronix-HNC-650nm-Red-Laser-Therapy-Device.jpg?v=1795246323","url":"https:\/\/healthyantrastore.com\/products\/biotronix-hnc-cold-laser-therapy-machine-650nm-red-808nm-infrared-lllt-device","provider":"Health Yantra Store","version":"1.0","type":"link"}