{"product_id":"cardiac-stress-test-system-tmt-machine-wireless-cw-usb","title":"Cardiac Stress Test System TMT Machine – Wireless CW-USB","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eCardiac Stress Test System TMT Machine – Wireless CW-USB\u003c\/strong\u003e is a Windows-based \u003cstrong\u003eTreadmill Test (TMT) and cardiac stress testing system\u003c\/strong\u003e designed for resting 12-lead ECG recording and exercise stress testing. The system combines an optically isolated amplifier, digital ECG filtering, automated stress-test protocols, graphical ST-HR trend analysis, comprehensive reporting, and an in-house fabricated medical-grade treadmill.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDesigned for clinical cardiac evaluation, the system supports both \u003cstrong\u003eresting ECGs and stress tests on a single platform\u003c\/strong\u003e, with options for wireless patient monitoring.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Wireless Cardiac Stress Test System is designed to provide a complete workflow for exercise-based cardiac stress testing. Its Windows-based stress-test software provides real-time ECG monitoring, post-test review, reporting, and printing capabilities.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system supports established exercise protocols including \u003cstrong\u003eBruce, Modified Bruce, Ellestad, and Naughton\u003c\/strong\u003e, along with user-editable protocols for customized testing requirements.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAn optional wireless patient module can be used where wireless ECG acquisition is required.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWireless Cardiac Stress Test System \/ TMT Machine\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOptically isolated ECG amplifier\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eWindows-based cardiac stress test software\u003c\/li\u003e\n\u003cli\u003eComprehensive stress-test reports\u003c\/li\u003e\n\u003cli\u003eOnline and offline printing\u003c\/li\u003e\n\u003cli\u003ePost-test review and editing facility\u003c\/li\u003e\n\u003cli\u003eDigital ECG filter for reduced noise\u003c\/li\u003e\n\u003cli\u003eBaseline correction algorithm for stable ECG waveforms\u003c\/li\u003e\n\u003cli\u003eGraphical \u003cstrong\u003eST-HR trend\u003c\/strong\u003e representation\u003c\/li\u003e\n\u003cli\u003eResting 12-lead ECG and stress testing on one system\u003c\/li\u003e\n\u003cli\u003eResting ECG axis and interval measurements\u003c\/li\u003e\n\u003cli\u003ePre-programmed Bruce protocol\u003c\/li\u003e\n\u003cli\u003eModified Bruce protocol\u003c\/li\u003e\n\u003cli\u003eEllestad protocol\u003c\/li\u003e\n\u003cli\u003eNaughton protocol\u003c\/li\u003e\n\u003cli\u003eUser-editable stress-test protocols\u003c\/li\u003e\n\u003cli\u003eMedical-grade treadmill\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 HP German Technology motor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAntistatic treadmill belt\u003c\/li\u003e\n\u003cli\u003eComprehensive treadmill safety features\u003c\/li\u003e\n\u003cli\u003eOptional wireless patient module\u003c\/li\u003e\n\u003cli\u003eService and spare-parts availability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eOptically Isolated ECG Amplifier\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system incorporates an \u003cstrong\u003eoptically isolated amplifier\u003c\/strong\u003e for ECG acquisition. Optical isolation separates the patient-side ECG acquisition circuitry from the relevant system electronics, supporting the electrical isolation requirements of clinical ECG equipment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWindows-Based Stress Test Software\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system uses \u003cstrong\u003eWindows-based stress test software\u003c\/strong\u003e designed to support the complete TMT workflow.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe software provides facilities for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time ECG monitoring\u003c\/li\u003e\n\u003cli\u003eStress-test data acquisition\u003c\/li\u003e\n\u003cli\u003eST-HR trend visualization\u003c\/li\u003e\n\u003cli\u003eComprehensive report generation\u003c\/li\u003e\n\u003cli\u003eOnline printing\u003c\/li\u003e\n\u003cli\u003eOffline printing\u003c\/li\u003e\n\u003cli\u003ePost-test review\u003c\/li\u003e\n\u003cli\u003eReport\/data editing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eDigital ECG Filtering \u0026amp; Baseline Correction\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe TMT system incorporates \u003cstrong\u003edigital filtering\u003c\/strong\u003e designed to reduce unwanted noise during ECG recording.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAn innovative \u003cstrong\u003ebaseline correction algorithm\u003c\/strong\u003e is specified to help maintain a steady ECG baseline and clear waveform presentation during stress testing.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eResting ECG \u0026amp; Stress Testing\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system can perform both:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eResting 12-lead ECG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eExercise cardiac stress testing\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThis allows resting ECG measurements and treadmill-based stress testing to be handled through a single system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor resting ECG examinations, the system provides \u003cstrong\u003eaxis and interval measurements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eStress-Test Protocols\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe software includes several pre-programmed exercise protocols:\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eBruce Protocol\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA commonly used staged treadmill exercise protocol.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eModified Bruce Protocol\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA modified version of the Bruce protocol suitable for selected clinical testing workflows.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eEllestad Protocol\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eAn additional staged exercise testing protocol available within the system.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eNaughton Protocol\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA lower-intensity staged protocol available for appropriate stress-test applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eUser-Editable Protocols\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system also allows protocols to be edited by the user according to the requirements of the clinical workflow.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eST-HR Trend Analysis\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe software provides a \u003cstrong\u003egraphical representation of ST-HR trends\u003c\/strong\u003e, allowing clinicians to review changes in ST-segment measurements in relation to heart rate during the stress-test procedure.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe graphical trend information can form part of the overall exercise ECG assessment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eMedical-Grade Treadmill\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system includes a \u003cstrong\u003eMedicaid in-house fabricated medical-grade treadmill\u003c\/strong\u003e driven by a \u003cstrong\u003e3 HP German Technology motor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe treadmill incorporates safety features intended for controlled exercise stress-testing environments.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAn \u003cstrong\u003eantistatic treadmill belt\u003c\/strong\u003e is also specified.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWireless Patient Module\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eAn \u003cstrong\u003eoptional wireless patient module\u003c\/strong\u003e is available for the system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis option can provide wireless ECG data acquisition between the patient and the stress-test system, reducing the need for a direct patient cable connection to the main system.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eReporting \u0026amp; Printing\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe software provides a comprehensive reporting workflow with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWide range of comprehensive reports\u003c\/li\u003e\n\u003cli\u003eOnline printing\u003c\/li\u003e\n\u003cli\u003eOffline printing\u003c\/li\u003e\n\u003cli\u003ePost-test review\u003c\/li\u003e\n\u003cli\u003eReport editing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThis can support clinical documentation and record keeping following stress-test examinations.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eService \u0026amp; Spare Parts\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe manufacturer states that \u003cstrong\u003eservice and spare parts are readily available\u003c\/strong\u003e, supporting ongoing maintenance of the TMT system.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCardiac Stress Test System \/ TMT Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWireless Device CW-USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eECG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResting 12-lead ECG \u0026amp; Stress Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptically isolated amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows-based Stress Test Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eECG Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaseline Correction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInnovative baseline correction algorithm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrend Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGraphical ST-HR trends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResting ECG Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAxis and interval measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStress Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBruce, Modified Bruce, Ellestad, Naughton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-editable protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreadmill\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedical-grade treadmill\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 HP German Technology motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreadmill Belt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAntistatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrinting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnline \/ Offline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReview\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePost-test review and edit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional wireless patient module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eService and spare parts availability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53337542656181,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Cardiac-Stress-Test-System-TMT-Machine-Medicaid.jpg?v=1789724496","url":"https:\/\/healthyantrastore.com\/products\/cardiac-stress-test-system-tmt-machine-wireless-cw-usb","provider":"Health Yantra Store","version":"1.0","type":"link"}