{"product_id":"contec-e18m-electrocardiograph-18-lead-ecg-machine","title":"Contec E18M Electrocardiograph – 18-Lead ECG Machine","description":"\u003cp dir=\"auto\" data-start=\"77\" data-end=\"451\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"81\" data-end=\"115\"\u003eContec E18M Electrocardiograph\u003c\/strong\u003e is an advanced \u003cstrong data-start=\"131\" data-end=\"167\"\u003esimultaneous 18-lead ECG machine\u003c\/strong\u003e designed for clinical and bedside cardiac assessment. It combines an \u003cstrong data-start=\"237\" data-end=\"267\"\u003e18-lead acquisition system\u003c\/strong\u003e, 10.1-inch color touchscreen, automatic ECG measurement and preliminary interpretation, extensive medical record storage, built-in thermal printing, and multiple connectivity options.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"453\" data-end=\"712\"\u003eThe E18M supports \u003cstrong data-start=\"471\" data-end=\"514\"\u003e3, 6, 12, and 18-lead waveform displays\u003c\/strong\u003e, along with \u003cstrong data-start=\"527\" data-end=\"560\"\u003eCabrera-lead waveform support\u003c\/strong\u003e. Its digital filtering system helps reduce common ECG signal interference, while the rechargeable lithium battery supports portable clinical operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"719\" data-end=\"736\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"738\" data-end=\"1668\"\u003e\n\u003cli data-section-id=\"l0enio\" data-start=\"738\" data-end=\"786\"\u003eSimultaneous \u003cstrong data-start=\"753\" data-end=\"786\"\u003e18-lead ECG signal collection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"2nh4lo\" data-start=\"787\" data-end=\"828\"\u003e\u003cstrong data-start=\"789\" data-end=\"828\"\u003e10.1-inch high-resolution color LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"82b4t4\" data-start=\"829\" data-end=\"860\"\u003e1280 × 800 display resolution\u003c\/li\u003e\n\u003cli data-section-id=\"8g8amr\" data-start=\"861\" data-end=\"913\"\u003eTouchscreen and physical function-button operation\u003c\/li\u003e\n\u003cli data-section-id=\"1czjkj7\" data-start=\"914\" data-end=\"962\"\u003eDisplay of 3, 6, 12, or 18 leads on one screen\u003c\/li\u003e\n\u003cli data-section-id=\"5oxt8x\" data-start=\"963\" data-end=\"994\"\u003eCabrera-lead waveform support\u003c\/li\u003e\n\u003cli data-section-id=\"1k5rczx\" data-start=\"995\" data-end=\"1027\"\u003eAdvanced digital ECG filtering\u003c\/li\u003e\n\u003cli data-section-id=\"l0bdhi\" data-start=\"1028\" data-end=\"1065\"\u003ePower-frequency interference filter\u003c\/li\u003e\n\u003cli data-section-id=\"rekjlf\" data-start=\"1066\" data-end=\"1089\"\u003eBaseline-drift filter\u003c\/li\u003e\n\u003cli data-section-id=\"1025edb\" data-start=\"1090\" data-end=\"1115\"\u003eEMG interference filter\u003c\/li\u003e\n\u003cli data-section-id=\"1cqyqcg\" data-start=\"1116\" data-end=\"1136\"\u003eLow-pass filtering\u003c\/li\u003e\n\u003cli data-section-id=\"1w0w7vb\" data-start=\"1137\" data-end=\"1174\"\u003eAutomatic ECG parameter measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1gom69\" data-start=\"1175\" data-end=\"1207\"\u003ePreliminary ECG interpretation\u003c\/li\u003e\n\u003cli data-section-id=\"1sglsub\" data-start=\"1208\" data-end=\"1251\"\u003eStores \u003cstrong data-start=\"1217\" data-end=\"1251\"\u003eat least 4,000 medical records\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h4djxm\" data-start=\"1252\" data-end=\"1278\"\u003eCase database management\u003c\/li\u003e\n\u003cli data-section-id=\"1forz9l\" data-start=\"1279\" data-end=\"1305\"\u003eBuilt-in thermal printer\u003c\/li\u003e\n\u003cli data-section-id=\"1nevsl\" data-start=\"1306\" data-end=\"1354\"\u003eMultiple automatic and manual printing formats\u003c\/li\u003e\n\u003cli data-section-id=\"1t1zpew\" data-start=\"1355\" data-end=\"1377\"\u003eRhythm-line printing\u003c\/li\u003e\n\u003cli data-section-id=\"4ru05e\" data-start=\"1378\" data-end=\"1404\"\u003eAdjustable grid settings\u003c\/li\u003e\n\u003cli data-section-id=\"1bbrfk8\" data-start=\"1405\" data-end=\"1428\"\u003eAC\/DC power operation\u003c\/li\u003e\n\u003cli data-section-id=\"10kk4ue\" data-start=\"1429\" data-end=\"1468\"\u003eBuilt-in rechargeable lithium battery\u003c\/li\u003e\n\u003cli data-section-id=\"1nvn3dy\" data-start=\"1469\" data-end=\"1498\"\u003eUp to 10 hours standby time\u003c\/li\u003e\n\u003cli data-section-id=\"r0au7v\" data-start=\"1499\" data-end=\"1541\"\u003eMore than 3 hours of continuous printing\u003c\/li\u003e\n\u003cli data-section-id=\"1sm964x\" data-start=\"1542\" data-end=\"1562\"\u003eWi-Fi connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"1rtpiha\" data-start=\"1563\" data-end=\"1581\"\u003eLAN connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"19jzsrt\" data-start=\"1582\" data-end=\"1600\"\u003eUSB connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"1aipwca\" data-start=\"1601\" data-end=\"1668\"\u003eSupport for external keyboard, mouse, barcode scanner and printer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1met64t\" dir=\"auto\" data-start=\"1675\" data-end=\"1704\"\u003e10.1-Inch Color Touchscreen\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1706\" data-end=\"1806\"\u003eThe Contec E18M features a \u003cstrong data-start=\"1733\" data-end=\"1805\"\u003e10.1-inch high-resolution color LCD with 1280 × 800 pixel resolution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1808\" data-end=\"1952\"\u003eThe display supports both \u003cstrong data-start=\"1834\" data-end=\"1889\"\u003etouchscreen operation and physical function buttons\u003c\/strong\u003e, providing flexible control during ECG acquisition and review.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1sspanz\" dir=\"auto\" data-start=\"1954\" data-end=\"1982\"\u003eWaveform Display Options\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1984\" data-end=\"2005\"\u003eThe E18M can display:\u003c\/p\u003e\n\u003cul data-start=\"2007\" data-end=\"2084\"\u003e\n\u003cli data-section-id=\"m7x4vu\" data-start=\"2007\" data-end=\"2025\"\u003e3-lead waveforms\u003c\/li\u003e\n\u003cli data-section-id=\"lu0fof\" data-start=\"2026\" data-end=\"2044\"\u003e6-lead waveforms\u003c\/li\u003e\n\u003cli data-section-id=\"hgurje\" data-start=\"2045\" data-end=\"2064\"\u003e12-lead waveforms\u003c\/li\u003e\n\u003cli data-section-id=\"m6owf4\" data-start=\"2065\" data-end=\"2084\"\u003e18-lead waveforms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2086\" data-end=\"2178\"\u003eMultiple waveform configurations can therefore be viewed according to the clinical workflow.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4q86u7\" dir=\"auto\" data-start=\"2185\" data-end=\"2223\"\u003eSimultaneous 18-Lead ECG Acquisition\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2225\" data-end=\"2293\"\u003eThe E18M is designed for \u003cstrong data-start=\"2250\" data-end=\"2292\"\u003esimultaneous 18-lead signal collection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2295\" data-end=\"2424\"\u003eIt also supports \u003cstrong data-start=\"2312\" data-end=\"2345\"\u003eCabrera-lead waveform display\u003c\/strong\u003e, providing an additional ECG lead presentation option for clinical assessment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"px3m0z\" dir=\"auto\" data-start=\"2431\" data-end=\"2463\"\u003eAdvanced Digital ECG Filtering\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2465\" data-end=\"2572\"\u003eThe electrocardiograph incorporates digital filtering designed to reduce various forms of ECG interference.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2574\" data-end=\"2603\"\u003eSupported filtering includes:\u003c\/p\u003e\n\u003cul data-start=\"2605\" data-end=\"2739\"\u003e\n\u003cli data-section-id=\"4whtnq\" data-start=\"2605\" data-end=\"2645\"\u003ePower-frequency interference filtering\u003c\/li\u003e\n\u003cli data-section-id=\"nq9pv\" data-start=\"2646\" data-end=\"2672\"\u003eBaseline-drift filtering\u003c\/li\u003e\n\u003cli data-section-id=\"xa9hh6\" data-start=\"2673\" data-end=\"2718\"\u003eElectromyogram (EMG) interference filtering\u003c\/li\u003e\n\u003cli data-section-id=\"1cqyqcg\" data-start=\"2719\" data-end=\"2739\"\u003eLow-pass filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2741\" data-end=\"2817\"\u003eThese functions help produce clearer ECG waveforms for review and recording.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1lumj0e\" dir=\"auto\" data-start=\"2824\" data-end=\"2880\"\u003eAutomatic ECG Measurement \u0026amp; Preliminary Interpretation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2882\" data-end=\"2948\"\u003eThe E18M automatically measures routine ECG parameters, including:\u003c\/p\u003e\n\u003cul data-start=\"2950\" data-end=\"3036\"\u003e\n\u003cli data-section-id=\"1ijcset\" data-start=\"2950\" data-end=\"2963\"\u003ePR interval\u003c\/li\u003e\n\u003cli data-section-id=\"1jb4i92\" data-start=\"2964\" data-end=\"2978\"\u003eQRS duration\u003c\/li\u003e\n\u003cli data-section-id=\"jph7f6\" data-start=\"2979\" data-end=\"2992\"\u003eQT interval\u003c\/li\u003e\n\u003cli data-section-id=\"zz3ur5\" data-start=\"2993\" data-end=\"3007\"\u003eQTc interval\u003c\/li\u003e\n\u003cli data-section-id=\"4duifv\" data-start=\"3008\" data-end=\"3016\"\u003eP axis\u003c\/li\u003e\n\u003cli data-section-id=\"1kbxzvf\" data-start=\"3017\" data-end=\"3027\"\u003eQRS axis\u003c\/li\u003e\n\u003cli data-section-id=\"6z1qov\" data-start=\"3028\" data-end=\"3036\"\u003eT axis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3038\" data-end=\"3161\"\u003eThe system also provides \u003cstrong data-start=\"3063\" data-end=\"3097\"\u003epreliminary ECG interpretation\u003c\/strong\u003e to assist healthcare professionals in reviewing ECG recordings.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ca5o49\" dir=\"auto\" data-start=\"3330\" data-end=\"3354\"\u003eMedical Record Storage\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3356\" data-end=\"3451\"\u003eThe Contec E18M includes a case database capable of storing \u003cstrong data-start=\"3416\" data-end=\"3450\"\u003eat least 4,000 medical records\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3453\" data-end=\"3467\"\u003eThis supports:\u003c\/p\u003e\n\u003cul data-start=\"3469\" data-end=\"3530\"\u003e\n\u003cli data-section-id=\"1laegx0\" data-start=\"3469\" data-end=\"3487\"\u003eECG case storage\u003c\/li\u003e\n\u003cli data-section-id=\"1ig37bz\" data-start=\"3488\" data-end=\"3503\"\u003eRecord review\u003c\/li\u003e\n\u003cli data-section-id=\"h4djxm\" data-start=\"3504\" data-end=\"3530\"\u003eCase database management\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3532\" data-end=\"3654\"\u003eThe extensive storage capacity can be useful for clinical environments where ECG records need to be retained and reviewed.\u003c\/p\u003e\n\u003ch3 data-section-id=\"89j693\" dir=\"auto\" data-start=\"3661\" data-end=\"3687\"\u003eBuilt-In Thermal Printer\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3689\" data-end=\"3759\"\u003eThe E18M features an integrated \u003cstrong data-start=\"3721\" data-end=\"3740\"\u003ethermal printer\u003c\/strong\u003e for ECG recording.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3761\" data-end=\"3782\"\u003eThe printer supports:\u003c\/p\u003e\n\u003cul data-start=\"3784\" data-end=\"3888\"\u003e\n\u003cli data-section-id=\"1xzr4yc\" data-start=\"3784\" data-end=\"3812\"\u003eAutomatic printing formats\u003c\/li\u003e\n\u003cli data-section-id=\"11n3olv\" data-start=\"3813\" data-end=\"3838\"\u003eManual printing formats\u003c\/li\u003e\n\u003cli data-section-id=\"1t1zpew\" data-start=\"3839\" data-end=\"3861\"\u003eRhythm-line printing\u003c\/li\u003e\n\u003cli data-section-id=\"4ru05e\" data-start=\"3862\" data-end=\"3888\"\u003eAdjustable grid settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3890\" data-end=\"3976\"\u003eThis provides flexibility for printing ECG records according to clinical requirements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"meqnw5\" dir=\"auto\" data-start=\"3983\" data-end=\"4023\"\u003eRechargeable Battery \u0026amp; AC\/DC Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4025\" data-end=\"4122\"\u003eThe E18M supports \u003cstrong data-start=\"4043\" data-end=\"4073\"\u003edual AC\/DC power operation\u003c\/strong\u003e and incorporates a rechargeable lithium battery.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4124\" data-end=\"4187\"\u003eAccording to the supplied specifications, the battery provides:\u003c\/p\u003e\n\u003cul data-start=\"4189\" data-end=\"4272\"\u003e\n\u003cli data-section-id=\"8zdx5b\" data-start=\"4189\" data-end=\"4225\"\u003eUp to \u003cstrong data-start=\"4197\" data-end=\"4225\"\u003e10 hours of standby time\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pq9xiz\" data-start=\"4226\" data-end=\"4272\"\u003eMore than \u003cstrong data-start=\"4238\" data-end=\"4272\"\u003e3 hours of continuous printing\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"4274\" data-end=\"4317\"\u003eThis supports portable and bedside ECG use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zjxypn\" dir=\"auto\" data-start=\"4694\" data-end=\"4720\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable data-start=\"4722\" data-end=\"5840\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4722\" data-end=\"4753\"\u003e\n\u003ctr data-start=\"4722\" data-end=\"4753\"\u003e\n\u003cth data-start=\"4722\" data-end=\"4738\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4738\" data-end=\"4753\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eContec E18M\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4764\" data-end=\"5840\"\u003e\n\u003ctr data-start=\"4764\" data-end=\"4809\"\u003e\n\u003ctd data-start=\"4764\" data-end=\"4779\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"4779\" data-end=\"4809\" data-col-size=\"sm\"\u003eDigital Electrocardiograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4810\" data-end=\"4833\"\u003e\n\u003ctd data-start=\"4810\" data-end=\"4822\" data-col-size=\"sm\"\u003eECG Leads\u003c\/td\u003e\n\u003ctd data-start=\"4822\" data-end=\"4833\" data-col-size=\"sm\"\u003e18-Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4834\" data-end=\"4883\"\u003e\n\u003ctd data-start=\"4834\" data-end=\"4848\" data-col-size=\"sm\"\u003eAcquisition\u003c\/td\u003e\n\u003ctd data-start=\"4848\" data-end=\"4883\" data-col-size=\"sm\"\u003eSimultaneous 18-Lead Collection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4884\" data-end=\"4917\"\u003e\n\u003ctd data-start=\"4884\" data-end=\"4894\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"4894\" data-end=\"4917\" data-col-size=\"sm\"\u003e10.1-inch Color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4918\" data-end=\"4945\"\u003e\n\u003ctd data-start=\"4918\" data-end=\"4931\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"4931\" data-end=\"4945\" data-col-size=\"sm\"\u003e1280 × 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4946\" data-end=\"5001\"\u003e\n\u003ctd data-start=\"4946\" data-end=\"4958\" data-col-size=\"sm\"\u003eOperation\u003c\/td\u003e\n\u003ctd data-start=\"4958\" data-end=\"5001\" data-col-size=\"sm\"\u003eTouchscreen + Physical Function Buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5002\" data-end=\"5045\"\u003e\n\u003ctd data-start=\"5002\" data-end=\"5021\" data-col-size=\"sm\"\u003eWaveform Display\u003c\/td\u003e\n\u003ctd data-start=\"5021\" data-end=\"5045\" data-col-size=\"sm\"\u003e3 \/ 6 \/ 12 \/ 18 Lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5046\" data-end=\"5075\"\u003e\n\u003ctd data-start=\"5046\" data-end=\"5062\" data-col-size=\"sm\"\u003eCabrera Leads\u003c\/td\u003e\n\u003ctd data-start=\"5062\" data-end=\"5075\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5076\" data-end=\"5103\"\u003e\n\u003ctd data-start=\"5076\" data-end=\"5096\" data-col-size=\"sm\"\u003eDigital Filtering\u003c\/td\u003e\n\u003ctd data-start=\"5096\" data-end=\"5103\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5104\" data-end=\"5136\"\u003e\n\u003ctd data-start=\"5104\" data-end=\"5129\" data-col-size=\"sm\"\u003ePower-Frequency Filter\u003c\/td\u003e\n\u003ctd data-start=\"5129\" data-end=\"5136\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5137\" data-end=\"5168\"\u003e\n\u003ctd data-start=\"5137\" data-end=\"5161\" data-col-size=\"sm\"\u003eBaseline-Drift Filter\u003c\/td\u003e\n\u003ctd data-start=\"5161\" data-end=\"5168\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5169\" data-end=\"5189\"\u003e\n\u003ctd data-start=\"5169\" data-end=\"5182\" data-col-size=\"sm\"\u003eEMG Filter\u003c\/td\u003e\n\u003ctd data-start=\"5182\" data-end=\"5189\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5190\" data-end=\"5215\"\u003e\n\u003ctd data-start=\"5190\" data-end=\"5208\" data-col-size=\"sm\"\u003eLow-Pass Filter\u003c\/td\u003e\n\u003ctd data-start=\"5208\" data-end=\"5215\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5216\" data-end=\"5247\"\u003e\n\u003ctd data-start=\"5216\" data-end=\"5240\" data-col-size=\"sm\"\u003eAutomatic Measurement\u003c\/td\u003e\n\u003ctd data-start=\"5240\" data-end=\"5247\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5248\" data-end=\"5298\"\u003e\n\u003ctd data-start=\"5248\" data-end=\"5265\" data-col-size=\"sm\"\u003eECG Parameters\u003c\/td\u003e\n\u003ctd data-start=\"5265\" data-end=\"5298\" data-col-size=\"sm\"\u003ePR, QRS, QT\/QTc, P\/QRS\/T Axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5299\" data-end=\"5335\"\u003e\n\u003ctd data-start=\"5299\" data-end=\"5328\" data-col-size=\"sm\"\u003ePreliminary Interpretation\u003c\/td\u003e\n\u003ctd data-start=\"5328\" data-end=\"5335\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5336\" data-end=\"5379\"\u003e\n\u003ctd data-start=\"5336\" data-end=\"5361\" data-col-size=\"sm\"\u003eMedical Record Storage\u003c\/td\u003e\n\u003ctd data-start=\"5361\" data-end=\"5379\" data-col-size=\"sm\"\u003e≥4,000 Records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5380\" data-end=\"5403\"\u003e\n\u003ctd data-start=\"5380\" data-end=\"5396\" data-col-size=\"sm\"\u003eCase Database\u003c\/td\u003e\n\u003ctd data-start=\"5396\" data-end=\"5403\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5404\" data-end=\"5434\"\u003e\n\u003ctd data-start=\"5404\" data-end=\"5422\" data-col-size=\"sm\"\u003eThermal Printer\u003c\/td\u003e\n\u003ctd data-start=\"5422\" data-end=\"5434\" data-col-size=\"sm\"\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5435\" data-end=\"5471\"\u003e\n\u003ctd data-start=\"5435\" data-end=\"5449\" data-col-size=\"sm\"\u003ePrint Modes\u003c\/td\u003e\n\u003ctd data-start=\"5449\" data-end=\"5471\" data-col-size=\"sm\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5472\" data-end=\"5500\"\u003e\n\u003ctd data-start=\"5472\" data-end=\"5487\" data-col-size=\"sm\"\u003eRhythm Lines\u003c\/td\u003e\n\u003ctd data-start=\"5487\" data-end=\"5500\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5501\" data-end=\"5532\"\u003e\n\u003ctd data-start=\"5501\" data-end=\"5519\" data-col-size=\"sm\"\u003eGrid Adjustment\u003c\/td\u003e\n\u003ctd data-start=\"5519\" data-end=\"5532\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5533\" data-end=\"5550\"\u003e\n\u003ctd data-start=\"5533\" data-end=\"5541\" data-col-size=\"sm\"\u003ePower\u003c\/td\u003e\n\u003ctd data-start=\"5541\" data-end=\"5550\" data-col-size=\"sm\"\u003eAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5551\" data-end=\"5593\"\u003e\n\u003ctd data-start=\"5551\" data-end=\"5561\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"5561\" data-end=\"5593\" data-col-size=\"sm\"\u003eRechargeable Lithium Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5594\" data-end=\"5627\"\u003e\n\u003ctd data-start=\"5594\" data-end=\"5609\" data-col-size=\"sm\"\u003eStandby Time\u003c\/td\u003e\n\u003ctd data-start=\"5609\" data-end=\"5627\" data-col-size=\"sm\"\u003eUp to 10 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5628\" data-end=\"5666\"\u003e\n\u003ctd data-start=\"5628\" data-end=\"5650\" data-col-size=\"sm\"\u003eContinuous Printing\u003c\/td\u003e\n\u003ctd data-start=\"5650\" data-end=\"5666\" data-col-size=\"sm\"\u003eOver 3 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5667\" data-end=\"5682\"\u003e\n\u003ctd data-start=\"5667\" data-end=\"5675\" data-col-size=\"sm\"\u003eWi-Fi\u003c\/td\u003e\n\u003ctd data-start=\"5675\" data-end=\"5682\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5683\" data-end=\"5696\"\u003e\n\u003ctd data-start=\"5683\" data-end=\"5689\" data-col-size=\"sm\"\u003eLAN\u003c\/td\u003e\n\u003ctd data-start=\"5689\" data-end=\"5696\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5697\" data-end=\"5710\"\u003e\n\u003ctd data-start=\"5697\" data-end=\"5703\" data-col-size=\"sm\"\u003eUSB\u003c\/td\u003e\n\u003ctd data-start=\"5703\" data-end=\"5710\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5711\" data-end=\"5744\"\u003e\n\u003ctd data-start=\"5711\" data-end=\"5731\" data-col-size=\"sm\"\u003eExternal Keyboard\u003c\/td\u003e\n\u003ctd data-start=\"5731\" data-end=\"5744\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5745\" data-end=\"5775\"\u003e\n\u003ctd data-start=\"5745\" data-end=\"5762\" data-col-size=\"sm\"\u003eExternal Mouse\u003c\/td\u003e\n\u003ctd data-start=\"5762\" data-end=\"5775\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5776\" data-end=\"5807\"\u003e\n\u003ctd data-start=\"5776\" data-end=\"5794\" data-col-size=\"sm\"\u003eBarcode Scanner\u003c\/td\u003e\n\u003ctd data-start=\"5794\" data-end=\"5807\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5808\" data-end=\"5840\"\u003e\n\u003ctd data-start=\"5808\" data-end=\"5827\" data-col-size=\"sm\"\u003eExternal Printer\u003c\/td\u003e\n\u003ctd data-start=\"5827\" data-end=\"5840\" data-col-size=\"sm\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Contec","offers":[{"title":"Default Title","offer_id":53419779358901,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Contec-E18M-ECG-Machine-18-Lead-ECG-Electrocardiograph.jpg?v=1791030730","url":"https:\/\/healthyantrastore.com\/products\/contec-e18m-electrocardiograph-18-lead-ecg-machine","provider":"Health Yantra Store","version":"1.0","type":"link"}