{"product_id":"contec-sp950-syringe-pump","title":"Contec SP950 Syringe Pump","description":"\u003cp data-start=\"792\" data-end=\"1182\"\u003eThe \u003cstrong data-start=\"796\" data-end=\"825\"\u003eContec SP950 Syringe Pump\u003c\/strong\u003e is an advanced microprocessor-controlled infusion system engineered to provide precise, reliable, and continuous intravenous medication delivery. Designed for demanding clinical environments, it combines intelligent infusion technology with comprehensive safety features to support accurate drug administration for neonatal, paediatric, and adult patients.\u003c\/p\u003e\n\u003cp data-start=\"1184\" data-end=\"1596\"\u003eFeaturing a \u003cstrong data-start=\"1196\" data-end=\"1224\"\u003e2.8-inch TFT LCD display\u003c\/strong\u003e, the SP950 provides real-time monitoring of infusion parameters, allowing clinicians to easily configure and supervise therapy. Automatic syringe size recognition simplifies setup and minimises programming errors, while compatibility with standard \u003cstrong data-start=\"1473\" data-end=\"1507\"\u003e10 ml, 20 ml, 30 ml, and 50 ml\u003c\/strong\u003e syringes ensures flexibility across a wide range of medications and treatment protocols.\u003c\/p\u003e\n\u003cp data-start=\"1598\" data-end=\"1971\"\u003eThe SP950 offers multiple infusion modes including \u003cstrong data-start=\"1649\" data-end=\"1657\"\u003eRate\u003c\/strong\u003e, \u003cstrong data-start=\"1659\" data-end=\"1667\"\u003eTime\u003c\/strong\u003e, and \u003cstrong data-start=\"1673\" data-end=\"1685\"\u003eGradient\u003c\/strong\u003e modes, allowing healthcare professionals to tailor infusion therapy according to individual patient requirements. Its intelligent occlusion monitoring with \u003cstrong data-start=\"1842\" data-end=\"1885\"\u003e10 adjustable pressure threshold levels\u003c\/strong\u003e continuously monitors infusion pressure and provides early warning of line blockages.\u003c\/p\u003e\n\u003cp data-start=\"1973\" data-end=\"2374\"\u003eComprehensive audible and visual alarms notify clinicians of occlusion, syringe displacement, near-empty syringe, battery exhaustion, communication errors, motor abnormalities, and other critical events. The automatic \u003cstrong data-start=\"2191\" data-end=\"2215\"\u003eKeep Vein Open (KVO)\u003c\/strong\u003e function maintains catheter patency after infusion completion, while the \u003cstrong data-start=\"2289\" data-end=\"2304\"\u003ePurge\/Bolus\u003c\/strong\u003e function supports rapid medication delivery when clinically required.\u003c\/p\u003e\n\u003cp data-start=\"2376\" data-end=\"2658\"\u003eDesigned with password-protected settings, treatment history review, rechargeable battery backup, and compatibility with central infusion management systems, the Contec SP950 is an ideal solution for modern hospitals seeking dependable infusion therapy with enhanced patient safety.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ma7m6t\" data-start=\"2665\" data-end=\"2680\"\u003eKey Features\u003c\/h3\u003e\n\u003ch3 data-section-id=\"148c8fw\" data-start=\"2682\" data-end=\"2709\"\u003eHigh-Precision Infusion\u003c\/h3\u003e\n\u003cul data-start=\"2710\" data-end=\"2855\"\u003e\n\u003cli data-section-id=\"e9wz1w\" data-start=\"2710\" data-end=\"2740\"\u003eInfusion accuracy of \u003cstrong data-start=\"2733\" data-end=\"2740\"\u003e±3%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1jubqte\" data-start=\"2741\" data-end=\"2769\"\u003eStable medication delivery\u003c\/li\u003e\n\u003cli data-section-id=\"1be4nry\" data-start=\"2770\" data-end=\"2813\"\u003eReliable microprocessor-controlled system\u003c\/li\u003e\n\u003cli data-section-id=\"11bwmwl\" data-start=\"2814\" data-end=\"2855\"\u003eSuitable for critical care applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1clzjis\" data-start=\"2857\" data-end=\"2885\"\u003e2.8-inch TFT LCD Display\u003c\/h3\u003e\n\u003cul data-start=\"2886\" data-end=\"3016\"\u003e\n\u003cli data-section-id=\"6wy88m\" data-start=\"2886\" data-end=\"2924\"\u003eReal-time infusion parameter display\u003c\/li\u003e\n\u003cli data-section-id=\"uqc5pm\" data-start=\"2925\" data-end=\"2957\"\u003eBright and easy-to-read screen\u003c\/li\u003e\n\u003cli data-section-id=\"8zpmvz\" data-start=\"2958\" data-end=\"2982\"\u003eSimple menu navigation\u003c\/li\u003e\n\u003cli data-section-id=\"1rs0i0d\" data-start=\"2983\" data-end=\"3016\"\u003eContinuous treatment monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"oo30ox\" data-start=\"3018\" data-end=\"3051\"\u003eAutomatic Syringe Recognition\u003c\/h3\u003e\n\u003cul data-start=\"3052\" data-end=\"3219\"\u003e\n\u003cli data-section-id=\"yxqnk1\" data-start=\"3052\" data-end=\"3088\"\u003eDetects syringe size automatically\u003c\/li\u003e\n\u003cli data-section-id=\"1v5c6l4\" data-start=\"3089\" data-end=\"3139\"\u003eSupports 10 ml, 20 ml, 30 ml, and 50 ml syringes\u003c\/li\u003e\n\u003cli data-section-id=\"vjf6oo\" data-start=\"3140\" data-end=\"3190\"\u003eCompatible with national standard (CNS) syringes\u003c\/li\u003e\n\u003cli data-section-id=\"2zux0p\" data-start=\"3191\" data-end=\"3219\"\u003eReduces programming errors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"17n9u5l\" data-start=\"3221\" data-end=\"3248\"\u003eMultiple Infusion Modes\u003c\/h3\u003e\n\u003cul data-start=\"3249\" data-end=\"3320\"\u003e\n\u003cli data-section-id=\"p1bnxl\" data-start=\"3249\" data-end=\"3260\"\u003eRate Mode\u003c\/li\u003e\n\u003cli data-section-id=\"1ipk3we\" data-start=\"3261\" data-end=\"3272\"\u003eTime Mode\u003c\/li\u003e\n\u003cli data-section-id=\"7rhql\" data-start=\"3273\" data-end=\"3288\"\u003eGradient Mode\u003c\/li\u003e\n\u003cli data-section-id=\"15y5u17\" data-start=\"3289\" data-end=\"3320\"\u003eFlexible infusion programming\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"16mf18o\" data-start=\"3322\" data-end=\"3357\"\u003eIntelligent Pressure Monitoring\u003c\/h3\u003e\n\u003cul data-start=\"3358\" data-end=\"3487\"\u003e\n\u003cli data-section-id=\"c8yxvl\" data-start=\"3358\" data-end=\"3400\"\u003e10 adjustable occlusion threshold levels\u003c\/li\u003e\n\u003cli data-section-id=\"1nddb7w\" data-start=\"3401\" data-end=\"3433\"\u003eContinuous pressure monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"hjrv4e\" data-start=\"3434\" data-end=\"3460\"\u003eEarly blockage detection\u003c\/li\u003e\n\u003cli data-section-id=\"x5nksl\" data-start=\"3461\" data-end=\"3487\"\u003eImproved infusion safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"t78xrw\" data-start=\"3489\" data-end=\"3519\"\u003eComprehensive Alarm System\u003c\/h3\u003e\n\u003cul data-start=\"3520\" data-end=\"3716\"\u003e\n\u003cli data-section-id=\"1kqowqt\" data-start=\"3520\" data-end=\"3547\"\u003eAudible and visual alarms\u003c\/li\u003e\n\u003cli data-section-id=\"yfuvfa\" data-start=\"3548\" data-end=\"3565\"\u003eOcclusion alarm\u003c\/li\u003e\n\u003cli data-section-id=\"1bih1ql\" data-start=\"3566\" data-end=\"3598\"\u003eSyringe displacement detection\u003c\/li\u003e\n\u003cli data-section-id=\"tpku67\" data-start=\"3599\" data-end=\"3627\"\u003eNear-empty syringe warning\u003c\/li\u003e\n\u003cli data-section-id=\"15czha8\" data-start=\"3628\" data-end=\"3662\"\u003eBattery low and exhausted alerts\u003c\/li\u003e\n\u003cli data-section-id=\"dwzdwk\" data-start=\"3663\" data-end=\"3688\"\u003eMotor abnormality alarm\u003c\/li\u003e\n\u003cli data-section-id=\"1cnvpmr\" data-start=\"3689\" data-end=\"3716\"\u003eCommunication error alarm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1qe2m0c\" data-start=\"3718\" data-end=\"3751\"\u003eKVO (Keep Vein Open) Function\u003c\/h3\u003e\n\u003cul data-start=\"3752\" data-end=\"3889\"\u003e\n\u003cli data-section-id=\"1qedxe0\" data-start=\"3752\" data-end=\"3803\"\u003eAutomatically activates after infusion completion\u003c\/li\u003e\n\u003cli data-section-id=\"4yjpu7\" data-start=\"3804\" data-end=\"3825\"\u003eAdjustable KVO rate\u003c\/li\u003e\n\u003cli data-section-id=\"1jfo30u\" data-start=\"3826\" data-end=\"3854\"\u003eMaintains catheter patency\u003c\/li\u003e\n\u003cli data-section-id=\"10ia83j\" data-start=\"3855\" data-end=\"3889\"\u003eSupports continuous patient care\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"fr800p\" data-start=\"3891\" data-end=\"3915\"\u003ePurge\/Bolus Function\u003c\/h3\u003e\n\u003cul data-start=\"3916\" data-end=\"4029\"\u003e\n\u003cli data-section-id=\"1muy275\" data-start=\"3916\" data-end=\"3943\"\u003eRapid medication delivery\u003c\/li\u003e\n\u003cli data-section-id=\"1x1oyca\" data-start=\"3944\" data-end=\"3967\"\u003eQuick IV line priming\u003c\/li\u003e\n\u003cli data-section-id=\"msdce1\" data-start=\"3968\" data-end=\"3998\"\u003eSupports emergency treatment\u003c\/li\u003e\n\u003cli data-section-id=\"15i62yt\" data-start=\"3999\" data-end=\"4029\"\u003eImproves workflow efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"177xuid\" data-start=\"4031\" data-end=\"4061\"\u003eData Management \u0026amp; Security\u003c\/h3\u003e\n\u003cul data-start=\"4062\" data-end=\"4220\"\u003e\n\u003cli data-section-id=\"2a2e0z\" data-start=\"4062\" data-end=\"4104\"\u003eSaves infusion parameters after shutdown\u003c\/li\u003e\n\u003cli data-section-id=\"d8wc5w\" data-start=\"4105\" data-end=\"4131\"\u003eTreatment history review\u003c\/li\u003e\n\u003cli data-section-id=\"1dwlar9\" data-start=\"4132\" data-end=\"4161\"\u003ePassword-protected settings\u003c\/li\u003e\n\u003cli data-section-id=\"8z4jaj\" data-start=\"4162\" data-end=\"4220\"\u003eSupports central infusion management system connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1e9tt4m\" data-start=\"4222\" data-end=\"4243\"\u003eDual Power Supply\u003c\/h3\u003e\n\u003cul data-start=\"4244\" data-end=\"4392\"\u003e\n\u003cli data-section-id=\"3qzgf4\" data-start=\"4244\" data-end=\"4264\"\u003eAC power operation\u003c\/li\u003e\n\u003cli data-section-id=\"10kk4ue\" data-start=\"4265\" data-end=\"4304\"\u003eBuilt-in rechargeable lithium battery\u003c\/li\u003e\n\u003cli data-section-id=\"1uwxqs8\" data-start=\"4305\" data-end=\"4332\"\u003eAutomatic power switching\u003c\/li\u003e\n\u003cli data-section-id=\"dax1fv\" data-start=\"4333\" data-end=\"4392\"\u003eReliable during patient transport and power interruptions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"2qq1z5\" data-start=\"4399\" data-end=\"4410\"\u003eBenefits\u003c\/h3\u003e\n\u003cul data-start=\"4412\" data-end=\"4831\"\u003e\n\u003cli data-section-id=\"mik0j1\" data-start=\"4412\" data-end=\"4454\"\u003eAccurate intravenous medication delivery\u003c\/li\u003e\n\u003cli data-section-id=\"17fz3s8\" data-start=\"4455\" data-end=\"4498\"\u003eIntelligent automatic syringe recognition\u003c\/li\u003e\n\u003cli data-section-id=\"3bbr2l\" data-start=\"4499\" data-end=\"4547\"\u003eMultiple infusion modes for flexible treatment\u003c\/li\u003e\n\u003cli data-section-id=\"1xd3ue6\" data-start=\"4548\" data-end=\"4581\"\u003eAdjustable occlusion monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"prhavc\" data-start=\"4582\" data-end=\"4621\"\u003eComprehensive safety alarm protection\u003c\/li\u003e\n\u003cli data-section-id=\"6nh0ay\" data-start=\"4622\" data-end=\"4670\"\u003eContinuous infusion during power interruptions\u003c\/li\u003e\n\u003cli data-section-id=\"1axn11e\" data-start=\"4671\" data-end=\"4707\"\u003eSecure password-protected settings\u003c\/li\u003e\n\u003cli data-section-id=\"1bbmi47\" data-start=\"4708\" data-end=\"4735\"\u003eTreatment history storage\u003c\/li\u003e\n\u003cli data-section-id=\"1j1oxit\" data-start=\"4736\" data-end=\"4780\"\u003eCompatible with central monitoring systems\u003c\/li\u003e\n\u003cli data-section-id=\"7rrewy\" data-start=\"4781\" data-end=\"4831\"\u003eIdeal for critical care and general hospital use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1cgu054\" data-start=\"4838\" data-end=\"4865\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4867\" data-end=\"5668\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4867\" data-end=\"4894\"\u003e\n\u003ctr data-start=\"4867\" data-end=\"4894\"\u003e\n\u003cth data-start=\"4867\" data-end=\"4883\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4883\" data-end=\"4894\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4922\" data-end=\"5668\"\u003e\n\u003ctr data-start=\"4922\" data-end=\"4953\"\u003e\n\u003ctd data-start=\"4922\" data-end=\"4937\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"4937\" data-end=\"4953\" data-col-size=\"md\"\u003eSyringe Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4954\" data-end=\"4972\"\u003e\n\u003ctd data-start=\"4954\" data-end=\"4962\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"4962\" data-end=\"4972\" data-col-size=\"md\"\u003eContec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4973\" data-end=\"4990\"\u003e\n\u003ctd data-start=\"4973\" data-end=\"4981\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"4981\" data-end=\"4990\" data-col-size=\"md\"\u003eSP950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4991\" data-end=\"5060\"\u003e\n\u003ctd data-start=\"4991\" data-end=\"5015\" data-col-size=\"sm\"\u003eSyringe Compatibility\u003c\/td\u003e\n\u003ctd data-start=\"5015\" data-end=\"5060\" data-col-size=\"md\"\u003e10 ml, 20 ml, 30 ml, 50 ml (CNS Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5061\" data-end=\"5088\"\u003e\n\u003ctd data-start=\"5061\" data-end=\"5081\" data-col-size=\"sm\"\u003eInfusion Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"5081\" data-end=\"5088\" data-col-size=\"md\"\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5089\" data-end=\"5150\"\u003e\n\u003ctd data-start=\"5089\" data-end=\"5105\" data-col-size=\"sm\"\u003eInfusion Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5105\" data-end=\"5150\"\u003e0.1–1200 ml\/h (depending on syringe size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5151\" data-end=\"5235\"\u003e\n\u003ctd data-start=\"5151\" data-end=\"5164\" data-col-size=\"sm\"\u003eBolus Rate\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5164\" data-end=\"5235\"\u003e10 ml: 200 ml\/h, 20 ml: 400 ml\/h, 30 ml: 600 ml\/h, 50 ml: 1200 ml\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5236\" data-end=\"5270\"\u003e\n\u003ctd data-start=\"5236\" data-end=\"5257\" data-col-size=\"sm\"\u003eAccumulated Volume\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5257\" data-end=\"5270\"\u003e0–9999 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5271\" data-end=\"5307\"\u003e\n\u003ctd data-start=\"5271\" data-end=\"5282\" data-col-size=\"sm\"\u003eKVO Rate\u003c\/td\u003e\n\u003ctd data-start=\"5282\" data-end=\"5307\" data-col-size=\"md\"\u003eAdjustable 0.1–5 ml\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5308\" data-end=\"5405\"\u003e\n\u003ctd data-start=\"5308\" data-end=\"5329\" data-col-size=\"sm\"\u003eOcclusion Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5329\" data-end=\"5405\"\u003eLow: 40 kPa (±16 kPa), Medium: 70 kPa (±30 kPa), High: 100 kPa (±35 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5406\" data-end=\"5436\"\u003e\n\u003ctd data-start=\"5406\" data-end=\"5416\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"5416\" data-end=\"5436\" data-col-size=\"md\"\u003e2.8-inch TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5437\" data-end=\"5476\"\u003e\n\u003ctd data-start=\"5437\" data-end=\"5452\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"5452\" data-end=\"5476\" data-col-size=\"md\"\u003eAC 100–240V, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5477\" data-end=\"5545\"\u003e\n\u003ctd data-start=\"5477\" data-end=\"5487\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"5487\" data-end=\"5545\" data-col-size=\"md\"\u003eBuilt-in Rechargeable Lithium Battery (7.4V, 5000 mAh)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5546\" data-end=\"5581\"\u003e\n\u003ctd data-start=\"5546\" data-end=\"5559\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"5559\" data-end=\"5581\" data-col-size=\"md\"\u003e305 × 132 × 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5582\" data-end=\"5609\"\u003e\n\u003ctd data-start=\"5582\" data-end=\"5591\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"5591\" data-end=\"5609\" data-col-size=\"md\"\u003eApprox. 1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5610\" data-end=\"5668\"\u003e\n\u003ctd data-start=\"5610\" data-end=\"5634\" data-col-size=\"sm\"\u003eSafety Classification\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5634\" data-end=\"5668\"\u003eClass II, Type BF Applied Part\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"5670\" data-end=\"5673\"\u003e\n\u003ch3 data-section-id=\"1vdrhtn\" data-start=\"5675\" data-end=\"5687\"\u003eIdeal For\u003c\/h3\u003e\n\u003cul data-start=\"5689\" data-end=\"5947\"\u003e\n\u003cli data-section-id=\"1m9masn\" data-start=\"5689\" data-end=\"5717\"\u003eIntensive Care Units (ICU)\u003c\/li\u003e\n\u003cli data-section-id=\"1ys42sp\" data-start=\"5718\" data-end=\"5745\"\u003eCoronary Care Units (CCU)\u003c\/li\u003e\n\u003cli data-section-id=\"1srq30b\" data-start=\"5746\" data-end=\"5784\"\u003eNeonatal Intensive Care Units (NICU)\u003c\/li\u003e\n\u003cli data-section-id=\"u3su5r\" data-start=\"5785\" data-end=\"5803\"\u003ePaediatric Wards\u003c\/li\u003e\n\u003cli data-section-id=\"1ugv01z\" data-start=\"5804\" data-end=\"5829\"\u003eOperating Theatres (OT)\u003c\/li\u003e\n\u003cli data-section-id=\"3qsaqe\" data-start=\"5830\" data-end=\"5853\"\u003eEmergency Departments\u003c\/li\u003e\n\u003cli data-section-id=\"tuvk17\" data-start=\"5854\" data-end=\"5873\"\u003eInternal Medicine\u003c\/li\u003e\n\u003cli data-section-id=\"1czduxu\" data-start=\"5874\" data-end=\"5895\"\u003eSurgery Departments\u003c\/li\u003e\n\u003cli data-section-id=\"37fygr\" data-start=\"5896\" data-end=\"5922\"\u003eObstetrics \u0026amp; Gynaecology\u003c\/li\u003e\n\u003cli data-section-id=\"1ej4r95\" data-start=\"5923\" data-end=\"5947\"\u003eGeneral Hospital Wards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w3a6bn\" data-start=\"5954\" data-end=\"5972\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul data-start=\"5974\" data-end=\"6059\"\u003e\n\u003cli data-section-id=\"j09oxu\" data-start=\"5974\" data-end=\"6001\"\u003eContec SP950 Syringe Pump\u003c\/li\u003e\n\u003cli data-section-id=\"1hrfanh\" data-start=\"6002\" data-end=\"6020\"\u003eMounting Bracket\u003c\/li\u003e\n\u003cli data-section-id=\"dl8dgt\" data-start=\"6021\" data-end=\"6033\"\u003ePower Cord\u003c\/li\u003e\n\u003cli data-section-id=\"10sdtyb\" data-start=\"6034\" data-end=\"6047\"\u003eUser Manual\u003c\/li\u003e\n\u003cli data-section-id=\"160yb76\" data-start=\"6048\" data-end=\"6059\"\u003eTwo Fuses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"cctytt\" data-start=\"6066\" data-end=\"6077\"\u003eWarranty\u003c\/h3\u003e\n\u003cp data-start=\"6079\" data-end=\"6236\"\u003eThe \u003cstrong data-start=\"6083\" data-end=\"6112\"\u003eContec SP950 Syringe Pump\u003c\/strong\u003e comes with a \u003cstrong data-start=\"6126\" data-end=\"6158\"\u003e1-year manufacturer warranty\u003c\/strong\u003e, providing confidence in product quality and dependable clinical performance.\u003c\/p\u003e","brand":"Contec","offers":[{"title":"Default Title","offer_id":52872129380533,"sku":null,"price":18500.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Contec-SP950-Syringe-Pump-1.png?v=1785222055","url":"https:\/\/healthyantrastore.com\/products\/contec-sp950-syringe-pump","provider":"Health Yantra Store","version":"1.0","type":"link"}