{"product_id":"contec-ts18-patient-monitor","title":"Contec TS18 Patient Monitor","description":"\u003cp dir=\"auto\" data-start=\"52\" data-end=\"402\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"56\" data-end=\"87\"\u003eContec TS18 Patient Monitor\u003c\/strong\u003e is an advanced modular clinical vital signs monitoring system designed for \u003cstrong data-start=\"163\" data-end=\"206\"\u003eadult, pediatric, and neonatal patients\u003c\/strong\u003e in high-acuity healthcare environments. It is suitable for \u003cstrong data-start=\"266\" data-end=\"401\"\u003eoperating rooms (OR), intensive care units (ICU), coronary care units (CCU), emergency rooms (ER), and other critical-care settings\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"404\" data-end=\"689\"\u003eFeaturing a \u003cstrong data-start=\"416\" data-end=\"450\"\u003e17.3-inch HD color touchscreen\u003c\/strong\u003e, modular hot-plug architecture, comprehensive ECG analysis, optional invasive blood pressure and CO₂ monitoring, and wired\/Wi-Fi central monitoring connectivity, the TS18 provides flexible patient monitoring in a single clinical platform.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"691\" data-end=\"898\"\u003eIts \u003cstrong data-start=\"695\" data-end=\"723\"\u003efanless processor design\u003c\/strong\u003e supports quiet operation, while the detachable high-capacity rechargeable lithium battery provides continued monitoring during power interruptions with automatic data saving.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"905\" data-end=\"922\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"924\" data-end=\"1755\"\u003e\n\u003cli data-section-id=\"1qtun3e\" data-start=\"924\" data-end=\"960\"\u003e\u003cstrong data-start=\"926\" data-end=\"960\"\u003e17.3-inch HD color touchscreen\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1qjoe6y\" data-start=\"961\" data-end=\"1006\"\u003eSimultaneous waveform and parameter display\u003c\/li\u003e\n\u003cli data-section-id=\"1iegjgk\" data-start=\"1007\" data-end=\"1065\"\u003eDesigned for \u003cstrong data-start=\"1022\" data-end=\"1065\"\u003eadult, pediatric, and neonatal patients\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wl1wy7\" data-start=\"1066\" data-end=\"1105\"\u003eModular \u003cstrong data-start=\"1076\" data-end=\"1105\"\u003ehot-plug parameter design\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"618348\" data-start=\"1106\" data-end=\"1143\"\u003eECG with \u003cstrong data-start=\"1117\" data-end=\"1143\"\u003eST-segment measurement\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q2ugso\" data-start=\"1144\" data-end=\"1165\"\u003e\u003cstrong data-start=\"1146\" data-end=\"1165\"\u003ePacing analysis\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1qiyncg\" data-start=\"1166\" data-end=\"1203\"\u003e\u003cstrong data-start=\"1168\" data-end=\"1203\"\u003e23 types of arrhythmia analysis\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"10k66wy\" data-start=\"1204\" data-end=\"1233\"\u003eRESP respiration monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"6fd7uk\" data-start=\"1234\" data-end=\"1266\"\u003eSpO₂ and pulse rate monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"xjiu09\" data-start=\"1267\" data-end=\"1301\"\u003eNIBP non-invasive blood pressure\u003c\/li\u003e\n\u003cli data-section-id=\"1j2t1qs\" data-start=\"1302\" data-end=\"1336\"\u003eTEMP body temperature monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"16nq2yz\" data-start=\"1337\" data-end=\"1379\"\u003eOptional \u003cstrong data-start=\"1348\" data-end=\"1379\"\u003eIBP invasive blood pressure\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1piumtp\" data-start=\"1380\" data-end=\"1421\"\u003eOptional \u003cstrong data-start=\"1391\" data-end=\"1421\"\u003eCO₂\/capnography monitoring\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1cflzb4\" data-start=\"1422\" data-end=\"1480\"\u003eIndependent physiological and technical alarm indicators\u003c\/li\u003e\n\u003cli data-section-id=\"wtl1hq\" data-start=\"1481\" data-end=\"1529\"\u003eWired or Wi-Fi central monitoring connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"1432hww\" data-start=\"1530\" data-end=\"1566\"\u003eQuiet \u003cstrong data-start=\"1538\" data-end=\"1566\"\u003efanless processor design\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mw8z0f\" data-start=\"1567\" data-end=\"1608\"\u003eDetachable rechargeable lithium battery\u003c\/li\u003e\n\u003cli data-section-id=\"1rasewe\" data-start=\"1609\" data-end=\"1654\"\u003eAutomatic data saving during power failures\u003c\/li\u003e\n\u003cli data-section-id=\"1tvm08p\" data-start=\"1655\" data-end=\"1685\"\u003eQuick patient-type switching\u003c\/li\u003e\n\u003cli data-section-id=\"b01fyb\" data-start=\"1686\" data-end=\"1704\"\u003eICU standby mode\u003c\/li\u003e\n\u003cli data-section-id=\"d0ygh2\" data-start=\"1705\" data-end=\"1755\"\u003eOptional \u003cstrong data-start=\"1716\" data-end=\"1755\"\u003e3-channel built-in thermal recorder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"w8nby8\" dir=\"auto\" data-start=\"1762\" data-end=\"1797\"\u003e17.3-Inch HD Touchscreen Display\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1799\" data-end=\"1949\"\u003eThe Contec TS18 features a large \u003cstrong data-start=\"1832\" data-end=\"1879\"\u003e17.3-inch high-definition color touchscreen\u003c\/strong\u003e designed to provide a clear view of patient parameters and waveforms.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1951\" data-end=\"2123\"\u003eThe display supports simultaneous presentation of monitored waveforms and numerical parameters, allowing clinical staff to review multiple vital signs from a single screen.\u003c\/p\u003e\n\u003ch3 data-section-id=\"t7gcuu\" dir=\"auto\" data-start=\"2130\" data-end=\"2165\"\u003eComprehensive Patient Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2167\" data-end=\"2241\"\u003eThe TS18 supports monitoring of a broad range of physiological parameters.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xxf9yf\" dir=\"auto\" data-start=\"2243\" data-end=\"2250\"\u003eECG\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2252\" data-end=\"2276\"\u003eThe ECG module provides:\u003c\/p\u003e\n\u003cul data-start=\"2278\" data-end=\"2380\"\u003e\n\u003cli data-section-id=\"1azced2\" data-start=\"2278\" data-end=\"2303\"\u003eECG waveform monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1cgqj0r\" data-start=\"2304\" data-end=\"2328\"\u003eST-segment measurement\u003c\/li\u003e\n\u003cli data-section-id=\"1ptos94\" data-start=\"2329\" data-end=\"2346\"\u003ePacing analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1ni56eo\" data-start=\"2347\" data-end=\"2380\"\u003e23 types of arrhythmia analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2382\" data-end=\"2473\"\u003eThese functions support continuous cardiac monitoring in high-acuity clinical environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ynojxu\" dir=\"auto\" data-start=\"2475\" data-end=\"2483\"\u003eRESP\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2485\" data-end=\"2617\"\u003eThe monitor provides \u003cstrong data-start=\"2506\" data-end=\"2537\"\u003erespiration rate monitoring\u003c\/strong\u003e, allowing respiratory activity to be observed alongside other vital parameters.\u003c\/p\u003e\n\u003ch3 data-section-id=\"12oqedo\" dir=\"auto\" data-start=\"2619\" data-end=\"2632\"\u003eSpO₂ \u0026amp; PR\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2634\" data-end=\"2652\"\u003eThe TS18 monitors:\u003c\/p\u003e\n\u003cul data-start=\"2654\" data-end=\"2710\"\u003e\n\u003cli data-section-id=\"6djv48\" data-start=\"2654\" data-end=\"2689\"\u003e\n\u003cstrong data-start=\"2656\" data-end=\"2665\"\u003eSpO₂:\u003c\/strong\u003e Blood oxygen saturation\u003c\/li\u003e\n\u003cli data-section-id=\"mnua0d\" data-start=\"2690\" data-end=\"2710\"\u003e\n\u003cstrong data-start=\"2692\" data-end=\"2699\"\u003ePR:\u003c\/strong\u003e Pulse rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2712\" data-end=\"2807\"\u003eBoth parameters can be viewed alongside the other patient waveforms and numerical measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ynf85v\" dir=\"auto\" data-start=\"2809\" data-end=\"2817\"\u003eNIBP\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2819\" data-end=\"2931\"\u003eNon-invasive blood pressure monitoring allows routine blood pressure assessment without invasive pressure lines.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ynq76y\" dir=\"auto\" data-start=\"2933\" data-end=\"2941\"\u003eTEMP\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2943\" data-end=\"3051\"\u003eThe monitor supports \u003cstrong data-start=\"2964\" data-end=\"2995\"\u003ebody temperature monitoring\u003c\/strong\u003e as part of its core vital-sign monitoring capabilities.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ico8xf\" dir=\"auto\" data-start=\"3053\" data-end=\"3069\"\u003eOptional IBP\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3071\" data-end=\"3180\"\u003e\u003cstrong data-start=\"3071\" data-end=\"3104\"\u003eInvasive blood pressure (IBP)\u003c\/strong\u003e can be supported through the modular architecture as an optional parameter.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1icoe6e\" dir=\"auto\" data-start=\"3182\" data-end=\"3198\"\u003eOptional CO₂\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3200\" data-end=\"3329\"\u003eThe TS18 can also be configured with \u003cstrong data-start=\"3237\" data-end=\"3267\"\u003eCO₂ monitoring\/capnography\u003c\/strong\u003e for environments where carbon dioxide monitoring is required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1wiwbak\" dir=\"auto\" data-start=\"3336\" data-end=\"3368\"\u003eModular Hot-Plug Architecture\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3370\" data-end=\"3450\"\u003eOne of the major features of the Contec TS18 is its \u003cstrong data-start=\"3422\" data-end=\"3449\"\u003emodular hot-plug design\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3452\" data-end=\"3659\"\u003eParameter modules can be plugged in, removed, or changed without requiring the monitor to be restarted. This allows the monitoring configuration to be adapted to different patients and clinical requirements.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3661\" data-end=\"3811\"\u003eThis modular approach is particularly useful in environments where monitoring requirements vary between \u003cstrong data-start=\"3765\" data-end=\"3810\"\u003eICU, CCU, OR, and emergency-care patients\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"z1d2rx\" dir=\"auto\" data-start=\"3818\" data-end=\"3842\"\u003eAdvanced Alarm System\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3844\" data-end=\"3934\"\u003eThe Contec TS18 incorporates \u003cstrong data-start=\"3873\" data-end=\"3933\"\u003eindependent physiological and technical alarm indicators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3936\" data-end=\"4092\"\u003eThis helps distinguish between patient-related physiological alarms and technical\/device-related conditions, supporting faster recognition by medical staff.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1a6qhnh\" dir=\"auto\" data-start=\"4099\" data-end=\"4134\"\u003eWired \u0026amp; Wi-Fi Central Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4136\" data-end=\"4236\"\u003eThe TS18 supports connection to a \u003cstrong data-start=\"4170\" data-end=\"4235\"\u003ecentral monitoring system through wired or Wi-Fi connectivity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4238\" data-end=\"4368\"\u003eThis enables monitored patient information to be transmitted to a central monitoring environment for broader clinical observation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kexc6i\" dir=\"auto\" data-start=\"4375\" data-end=\"4403\"\u003eFanless \u0026amp; Quiet Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4405\" data-end=\"4492\"\u003eThe monitor uses a \u003cstrong data-start=\"4424\" data-end=\"4459\"\u003equiet, fanless processor design\u003c\/strong\u003e, helping reduce operating noise.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4494\" data-end=\"4643\"\u003eThis is particularly useful in environments such as ICUs and other patient-care areas where minimizing unnecessary equipment noise can be beneficial.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4645\" data-end=\"4770\"\u003eThe monitor also features a \u003cstrong data-start=\"4673\" data-end=\"4707\"\u003eluminous physical power button\u003c\/strong\u003e, making operation easier in low-light or nighttime conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"j0xvth\" dir=\"auto\" data-start=\"4777\" data-end=\"4819\"\u003eRechargeable Battery \u0026amp; Power Protection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4821\" data-end=\"4908\"\u003eThe Contec TS18 features a \u003cstrong data-start=\"4848\" data-end=\"4907\"\u003edetachable, large-capacity rechargeable lithium battery\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4910\" data-end=\"5091\"\u003eDuring a power interruption, the system supports continued monitoring and \u003cstrong data-start=\"4984\" data-end=\"5009\"\u003eautomatic data saving\u003c\/strong\u003e, helping protect patient monitoring information during unexpected power failures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"sm5zas\" dir=\"auto\" data-start=\"5098\" data-end=\"5129\"\u003ePatient-Type Quick Switching\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5131\" data-end=\"5174\"\u003eThe monitor allows quick selection between:\u003c\/p\u003e\n\u003cul data-start=\"5176\" data-end=\"5218\"\u003e\n\u003cli data-section-id=\"1rbi9y8\" data-start=\"5176\" data-end=\"5187\"\u003e\u003cstrong data-start=\"5178\" data-end=\"5187\"\u003eAdult\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"14gs3dp\" data-start=\"5188\" data-end=\"5203\"\u003e\u003cstrong data-start=\"5190\" data-end=\"5203\"\u003ePediatric\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"15eemgq\" data-start=\"5204\" data-end=\"5218\"\u003e\u003cstrong data-start=\"5206\" data-end=\"5218\"\u003eNeonatal\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5220\" data-end=\"5310\"\u003eThis provides a convenient way to configure the monitor for different patient populations.\u003c\/p\u003e\n\u003ch3 data-section-id=\"bzd98u\" dir=\"auto\" data-start=\"5317\" data-end=\"5336\"\u003eICU Standby Mode\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5338\" data-end=\"5492\"\u003eA \u003cstrong data-start=\"5340\" data-end=\"5356\"\u003estandby mode\u003c\/strong\u003e is available for situations where the patient needs a temporary monitoring pause, such as during periods of rest in an ICU environment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tbstwn\" dir=\"auto\" data-start=\"5499\" data-end=\"5537\"\u003eOptional 3-Channel Thermal Recorder\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5539\" data-end=\"5677\"\u003eThe Contec TS18 can be configured with an \u003cstrong data-start=\"5581\" data-end=\"5629\"\u003eoptional 3-channel built-in thermal recorder\u003c\/strong\u003e for printed monitoring information and records.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"5684\" data-end=\"5711\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5713\" data-end=\"6564\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5713\" data-end=\"5744\"\u003e\n\u003ctr data-start=\"5713\" data-end=\"5744\"\u003e\n\u003cth data-start=\"5713\" data-end=\"5729\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"5729\" data-end=\"5744\" data-col-size=\"md\" class=\"last:pe-10\"\u003eContec TS18\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5755\" data-end=\"6564\"\u003e\n\u003ctr data-start=\"5755\" data-end=\"5797\"\u003e\n\u003ctd data-start=\"5755\" data-end=\"5770\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"5770\" data-end=\"5797\" data-col-size=\"md\"\u003eModular Patient Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5798\" data-end=\"5846\"\u003e\n\u003ctd data-start=\"5798\" data-end=\"5814\" data-col-size=\"sm\"\u003ePatient Types\u003c\/td\u003e\n\u003ctd data-start=\"5814\" data-end=\"5846\" data-col-size=\"md\"\u003eAdult \/ Pediatric \/ Neonatal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5847\" data-end=\"5891\"\u003e\n\u003ctd data-start=\"5847\" data-end=\"5857\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"5857\" data-end=\"5891\" data-col-size=\"md\"\u003e17.3-inch HD Color Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5892\" data-end=\"5905\"\u003e\n\u003ctd data-start=\"5892\" data-end=\"5898\" data-col-size=\"sm\"\u003eECG\u003c\/td\u003e\n\u003ctd data-start=\"5898\" data-end=\"5905\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5906\" data-end=\"5964\"\u003e\n\u003ctd data-start=\"5906\" data-end=\"5921\" data-col-size=\"sm\"\u003eECG Features\u003c\/td\u003e\n\u003ctd data-start=\"5921\" data-end=\"5964\" data-col-size=\"md\"\u003eST Segment Measurement, Pacing Analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5965\" data-end=\"5999\"\u003e\n\u003ctd data-start=\"5965\" data-end=\"5987\" data-col-size=\"sm\"\u003eArrhythmia Analysis\u003c\/td\u003e\n\u003ctd data-start=\"5987\" data-end=\"5999\" data-col-size=\"md\"\u003e23 Types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6000\" data-end=\"6014\"\u003e\n\u003ctd data-start=\"6000\" data-end=\"6007\" data-col-size=\"sm\"\u003eRESP\u003c\/td\u003e\n\u003ctd data-start=\"6007\" data-end=\"6014\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6015\" data-end=\"6029\"\u003e\n\u003ctd data-start=\"6015\" data-end=\"6022\" data-col-size=\"sm\"\u003eSpO₂\u003c\/td\u003e\n\u003ctd data-start=\"6022\" data-end=\"6029\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6030\" data-end=\"6042\"\u003e\n\u003ctd data-start=\"6030\" data-end=\"6035\" data-col-size=\"sm\"\u003ePR\u003c\/td\u003e\n\u003ctd data-start=\"6035\" data-end=\"6042\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6043\" data-end=\"6057\"\u003e\n\u003ctd data-start=\"6043\" data-end=\"6050\" data-col-size=\"sm\"\u003eNIBP\u003c\/td\u003e\n\u003ctd data-start=\"6050\" data-end=\"6057\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6058\" data-end=\"6072\"\u003e\n\u003ctd data-start=\"6058\" data-end=\"6065\" data-col-size=\"sm\"\u003eTEMP\u003c\/td\u003e\n\u003ctd data-start=\"6065\" data-end=\"6072\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6073\" data-end=\"6101\"\u003e\n\u003ctd data-start=\"6073\" data-end=\"6079\" data-col-size=\"sm\"\u003eIBP\u003c\/td\u003e\n\u003ctd data-start=\"6079\" data-end=\"6101\" data-col-size=\"md\"\u003eOptional \/ Modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6102\" data-end=\"6130\"\u003e\n\u003ctd data-start=\"6102\" data-end=\"6108\" data-col-size=\"sm\"\u003eCO₂\u003c\/td\u003e\n\u003ctd data-start=\"6108\" data-end=\"6130\" data-col-size=\"md\"\u003eOptional \/ Modular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6131\" data-end=\"6168\"\u003e\n\u003ctd data-start=\"6131\" data-end=\"6148\" data-col-size=\"sm\"\u003eModular Design\u003c\/td\u003e\n\u003ctd data-start=\"6148\" data-end=\"6168\" data-col-size=\"md\"\u003eHot-Plug Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6169\" data-end=\"6236\"\u003e\n\u003ctd data-start=\"6169\" data-end=\"6184\" data-col-size=\"sm\"\u003eAlarm System\u003c\/td\u003e\n\u003ctd data-start=\"6184\" data-end=\"6236\" data-col-size=\"md\"\u003eIndependent Physiological \u0026amp; Technical Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6237\" data-end=\"6275\"\u003e\n\u003ctd data-start=\"6237\" data-end=\"6258\" data-col-size=\"sm\"\u003eCentral Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"6258\" data-end=\"6275\" data-col-size=\"md\"\u003eWired \/ Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6276\" data-end=\"6306\"\u003e\n\u003ctd data-start=\"6276\" data-end=\"6295\" data-col-size=\"sm\"\u003eProcessor Design\u003c\/td\u003e\n\u003ctd data-start=\"6295\" data-end=\"6306\" data-col-size=\"md\"\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6307\" data-end=\"6375\"\u003e\n\u003ctd data-start=\"6307\" data-end=\"6317\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"6317\" data-end=\"6375\" data-col-size=\"md\"\u003eDetachable Large-Capacity Rechargeable Lithium Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6376\" data-end=\"6428\"\u003e\n\u003ctd data-start=\"6376\" data-end=\"6403\" data-col-size=\"sm\"\u003ePower-Failure Protection\u003c\/td\u003e\n\u003ctd data-start=\"6403\" data-end=\"6428\" data-col-size=\"md\"\u003eAutomatic Data Saving\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6429\" data-end=\"6481\"\u003e\n\u003ctd data-start=\"6429\" data-end=\"6449\" data-col-size=\"sm\"\u003ePatient Switching\u003c\/td\u003e\n\u003ctd data-start=\"6449\" data-end=\"6481\" data-col-size=\"md\"\u003eAdult \/ Pediatric \/ Neonatal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6482\" data-end=\"6504\"\u003e\n\u003ctd data-start=\"6482\" data-end=\"6497\" data-col-size=\"sm\"\u003eStandby Mode\u003c\/td\u003e\n\u003ctd data-start=\"6497\" data-end=\"6504\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6505\" data-end=\"6564\"\u003e\n\u003ctd data-start=\"6505\" data-end=\"6524\" data-col-size=\"sm\"\u003eThermal Recorder\u003c\/td\u003e\n\u003ctd data-start=\"6524\" data-end=\"6564\" data-col-size=\"md\"\u003eOptional 3-Channel Built-In Recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Contec","offers":[{"title":"Default Title","offer_id":53419480973493,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Contec-TS18-Patient-Monitor-17.3_-Modular-Monitor.jpg?v=1791023169","url":"https:\/\/healthyantrastore.com\/products\/contec-ts18-patient-monitor","provider":"Health Yantra Store","version":"1.0","type":"link"}