{"product_id":"dales-organ-bath-bm-707-organ-bath-for-pharmacology-research-teaching","title":"Dale's Organ Bath BM 707 – Organ Bath for Pharmacology Research \u0026 Teaching","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eDale's Organ Bath BM 707\u003c\/strong\u003e is a laboratory organ bath system designed for accurate recording of \u003cstrong\u003eisometric and isotonic tissue contraction and relaxation\u003c\/strong\u003e. It is intended for pharmacology research and teaching applications involving isolated tissues, including \u003cstrong\u003esmooth muscle, uterus, blood vessel strips, auricle, and other experimental tissue preparations\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system combines thermostatic temperature control, stirring, built-in stimulation, TFT-based data display, internal recording storage, USB computer connectivity, and PC software for reviewing and printing experimental data.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Dale's Organ Bath BM 707 provides a controlled experimental environment for studying the response of isolated tissues to \u003cstrong\u003epharmacological agents and electrical stimulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIts thermostatic temperature-control system with an integrated stirrer is designed to maintain suitable experimental conditions, while the built-in stimulators allow electrical stimulation studies to be performed using the same system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eRecorded experimental data can be displayed and stored on the TFT monitor, reviewed later, and transferred to a computer through USB for further review and printing.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eisometric and isotonic tissue contraction\/relaxation recording\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for pharmacology research and teaching\u003c\/li\u003e\n\u003cli\u003eLeak-proof dovetailed joints\u003c\/li\u003e\n\u003cli\u003eSturdy metal supporting frame\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy recording system\u003c\/li\u003e\n\u003cli\u003eThermostatic temperature control\u003c\/li\u003e\n\u003cli\u003eIntegrated stirrer\u003c\/li\u003e\n\u003cli\u003eBuilt-in stimulators\u003c\/li\u003e\n\u003cli\u003eTFT monitor for data display\u003c\/li\u003e\n\u003cli\u003eRecording data storage and review on TFT\u003c\/li\u003e\n\u003cli\u003eUSB interface for computer connectivity\u003c\/li\u003e\n\u003cli\u003ePC software for data review and printing\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e11-step sensitivity adjustment\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMultiple sweep-speed selections\u003c\/li\u003e\n\u003cli\u003eComplete accessory set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eIsometric \u0026amp; Isotonic Tissue Recording\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BM 707 is designed for recording both:\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eIsometric Contraction\/Relaxation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eUsed when changes in tissue tension or force are recorded while the tissue length is maintained.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eIsotonic Contraction\/Relaxation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eUsed when tissue length or displacement is recorded under the applicable experimental conditions.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis allows researchers and students to perform different types of isolated-tissue experiments using the same organ bath platform.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003ePharmacology Research Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe organ bath is intended for classic pharmacology experiments involving the response of isolated tissues to \u003cstrong\u003edrugs and electrical stimuli\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe supplied applications include research involving:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIsolated smooth muscle\u003c\/li\u003e\n\u003cli\u003eUterus\u003c\/li\u003e\n\u003cli\u003eBlood vessel strips\u003c\/li\u003e\n\u003cli\u003eAuricle\u003c\/li\u003e\n\u003cli\u003eOther isolated tissue preparations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eIt can be used for studying tissue contraction and relaxation responses under controlled laboratory conditions.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eThermostatic Temperature Control \u0026amp; Stirrer\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BM 707 incorporates \u003cstrong\u003ethermostatic temperature control with a stirrer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eTemperature control and continuous stirring are important components of controlled organ-bath experiments, helping maintain the experimental environment specified for a particular tissue preparation and study protocol.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eBuilt-In Stimulator\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system includes \u003cstrong\u003ebuilt-in stimulators\u003c\/strong\u003e, allowing electrical stimulation experiments to be performed directly using the organ bath system.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is useful for experimental protocols where tissue response to electrical stimulation needs to be recorded.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTFT Monitor \u0026amp; Data Storage\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BM 707 includes a \u003cstrong\u003eTFT monitor\u003c\/strong\u003e for displaying experimental data.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system also provides facilities to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStore recording data\u003c\/li\u003e\n\u003cli\u003eReview stored recordings on the TFT\u003c\/li\u003e\n\u003cli\u003eExamine experimental results after acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThis reduces reliance on immediate external computer processing during the experiment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eUSB Computer Interface\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA built-in \u003cstrong\u003eUSB interface\u003c\/strong\u003e allows the organ bath system to connect with a computer.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eDedicated software is provided for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReviewing recorded data\u003c\/li\u003e\n\u003cli\u003eProcessing\/observing experimental recordings\u003c\/li\u003e\n\u003cli\u003ePrinting recorded data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eSensitivity Adjustment\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system provides \u003cstrong\u003e11 sensitivity steps\u003c\/strong\u003e, allowing the recording sensitivity to be adjusted according to the requirements of the experiment and tissue response being measured.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eSweep Speed\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BM 707 provides multiple sweep-speed settings:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 and 100 div\/sec\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis range allows the recording speed to be selected according to the experimental protocol and response characteristics.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eSturdy \u0026amp; Leak-Proof Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe organ bath incorporates \u003cstrong\u003eleak-proof dovetailed joints\u003c\/strong\u003e and is mounted in a \u003cstrong\u003esturdy metal frame\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe construction is designed for stable laboratory use during tissue experiments.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDale's Organ Bath\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBM 707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePharmacology Research \u0026amp; Teaching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecording Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsometric \u0026amp; Isotonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTissue contraction \/ relaxation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeak-proof dovetailed joints\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSturdy metal frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermostatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStirring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in stirrer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStimulator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRecording data storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Review\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTFT-based review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComputer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eData review \u0026amp; printing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSweep Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100 div\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComplete set of accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53338531233973,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Dale_s-Organ-Bath-BM-707-Pharmacology-Teaching-Equipment.jpg?v=1789737554","url":"https:\/\/healthyantrastore.com\/products\/dales-organ-bath-bm-707-organ-bath-for-pharmacology-research-teaching","provider":"Health Yantra Store","version":"1.0","type":"link"}