{"product_id":"drager-evita-4-icu-ventilator","title":"Dräger Evita 4 ICU Ventilator","description":"\u003cp\u003eThe \u003cstrong\u003eDräger Evita 4\u003c\/strong\u003e is an advanced intensive care mechanical ventilator designed to provide respiratory support for \u003cstrong\u003eadult, pediatric, and neonatal patients\u003c\/strong\u003e. Its modular architecture, full-color display, and microprocessor-controlled ventilation platform allow it to support a broad range of invasive and spontaneous breathing applications in critical-care environments.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003erefurbished Dräger Evita 4 ventilator\u003c\/strong\u003e offers multiple ventilation strategies, including IPPV\/CPPV, SIMV, MMV, BIPAP\/APRV, CPAP and assisted spontaneous breathing. Advanced functions such as \u003cstrong\u003eAutoFlow, apnea ventilation, intrinsic PEEP measurement, compliance monitoring and MEDIBUS connectivity\u003c\/strong\u003e support comprehensive clinical ventilation management.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdult, pediatric \u0026amp; neonatal support:\u003c\/strong\u003e Designed for a broad patient population.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced microprocessor control:\u003c\/strong\u003e Manages complex ventilation and monitoring functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull-color display:\u003c\/strong\u003e Provides clear visualization of ventilation parameters and waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple ventilation modes:\u003c\/strong\u003e IPPV\/CPPV, SIMV, MMV, BIPAP\/APRV, CPAP and ASB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutoFlow:\u003c\/strong\u003e Automatically regulates inspiratory flow during volume-controlled ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time waveforms:\u003c\/strong\u003e Displays pressure, flow and volume curves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive monitoring:\u003c\/strong\u003e Tracks expiratory minute volume, tidal volume, oxygen concentration and breathing-gas temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntrinsic PEEP calculation:\u003c\/strong\u003e Provides Auto-PEEP measurement capability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance tracking:\u003c\/strong\u003e Supports assessment of respiratory system compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspiratory \u0026amp; expiratory hold:\u003c\/strong\u003e Allows special respiratory maneuvers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApnea ventilation:\u003c\/strong\u003e Automatically switches to mandatory ventilation when apnea is detected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas-supply logic:\u003c\/strong\u003e Can shift to an alternative functional gas input when line pressure is lost.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMEDIBUS connectivity:\u003c\/strong\u003e Supports external data exchange using the MEDIBUS protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModular construction:\u003c\/strong\u003e Designed for flexible configuration and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Ventilation Modes\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIPPV \/ CPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermittent or continuous positive pressure ventilation, with optional AutoFlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized intermittent mandatory ventilation using volume- or pressure-controlled breaths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMandatory Minute Volume ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBIPAP \/ APRV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBiphasic positive airway pressure \/ airway pressure release ventilation supporting spontaneous breathing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpontaneous breathing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous positive airway pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eASB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAssisted spontaneous breathing \/ pressure support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eAutoFlow Technology\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAutoFlow\u003c\/strong\u003e function automatically regulates inspiratory flow during volume-controlled ventilation.\u003c\/p\u003e\n\u003cp\u003eThis allows the ventilator to adjust inspiratory flow according to the selected ventilation requirements while maintaining the intended volume-controlled ventilation strategy.\u003c\/p\u003e\n\u003ch3\u003eMonitoring \u0026amp; Waveforms\u003c\/h3\u003e\n\u003cp\u003eThe Evita 4 provides real-time visualization and measurement of important respiratory parameters.\u003c\/p\u003e\n\u003ch3\u003eWaveform Display\u003c\/h3\u003e\n\u003cp\u003eThe system can display:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure curves\u003c\/li\u003e\n\u003cli\u003eFlow curves\u003c\/li\u003e\n\u003cli\u003eVolume curves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasured Parameters\u003c\/h3\u003e\n\u003cp\u003eThe supplied specifications include monitoring of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExpiratory minute volume\u003c\/li\u003e\n\u003cli\u003eTidal volume\u003c\/li\u003e\n\u003cli\u003eOxygen concentration\u003c\/li\u003e\n\u003cli\u003eBreathing-gas temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRespiratory Mechanics\u003c\/h3\u003e\n\u003cp\u003eSpecial functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspiratory hold\u003c\/li\u003e\n\u003cli\u003eExpiratory hold\u003c\/li\u003e\n\u003cli\u003eCompliance tracking\u003c\/li\u003e\n\u003cli\u003eIntrinsic PEEP \/ Auto-PEEP calculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety \u0026amp; Backup Functions\u003c\/h3\u003e\n\u003ch3\u003eApnea Ventilation\u003c\/h3\u003e\n\u003cp\u003eIf spontaneous breathing stops, the ventilator can automatically switch to \u003cstrong\u003emandatory ventilation\u003c\/strong\u003e as an apnea backup function.\u003c\/p\u003e\n\u003ch3\u003eGas Supply Logic\u003c\/h3\u003e\n\u003cp\u003eThe gas-supply system can automatically shift to an alternative functional gas input when a loss of line pressure is detected.\u003c\/p\u003e\n\u003cp\u003eThese functions are intended to provide additional operational safety during mechanical ventilation.\u003c\/p\u003e\n\u003ch3\u003eMEDIBUS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe Dräger Evita 4 supports the \u003cstrong\u003eMEDIBUS protocol\u003c\/strong\u003e for external data exchange.\u003c\/p\u003e\n\u003cp\u003eDepending on the installed configuration and connected equipment, this can support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVentilator data transfer\u003c\/li\u003e\n\u003cli\u003eExternal monitoring integration\u003c\/li\u003e\n\u003cli\u003eClinical data acquisition\u003c\/li\u003e\n\u003cli\u003eSystem connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDräger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEvita 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICU mechanical ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Population\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdult, pediatric \u0026amp; neonatal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-color screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIPPV \/ CPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutoFlow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBIPAP \/ APRV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSB \/ CPAP \/ ASB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure, flow \u0026amp; volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinute Volume Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExpiratory MV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTidal Volume Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eO₂ Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Temperature Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-PEEP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrinsic PEEP calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInspiratory Hold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpiratory Hold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApnea Ventilation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Supply Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic alternative gas-input selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMEDIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntensive care respiratory support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53211879211189,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Dr_ger-Evita-4-Refurbished-Ventilator-Price-India.jpg?v=1788515868","url":"https:\/\/healthyantrastore.com\/products\/drager-evita-4-icu-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}