{"product_id":"drager-evita-xl-icu-ventilator","title":"Dräger Evita XL ICU Ventilator","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eRefurbished Dräger Evita XL Ventilator\u003c\/strong\u003e is an advanced \u003cstrong\u003eICU mechanical ventilator\u003c\/strong\u003e designed to provide invasive and non-invasive respiratory support for \u003cstrong\u003eadult, pediatric, and neonatal patients\u003c\/strong\u003e. Its broad patient compatibility makes it suitable for intensive-care environments requiring ventilation support across different age groups.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDräger Evita XL\u003c\/strong\u003e supports long-term ventilation and offers a comprehensive selection of standard and advanced ventilation modes. With the \u003cstrong\u003eNeoFlow option\u003c\/strong\u003e, the system can also support ventilation of premature infants according to the supplied product information.\u003c\/p\u003e\n\u003cp\u003eThe ventilator incorporates \u003cstrong\u003eNIV Plus\u003c\/strong\u003e for mask ventilation with advanced leak compensation, helping maintain effective non-invasive ventilation. Its open breathing system incorporates \u003cstrong\u003eAutoFlow and PCV+\u003c\/strong\u003e capabilities to facilitate smooth transitions toward spontaneous breathing.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRefurbished Dräger Evita XL\u003c\/strong\u003e also features integrated \u003cstrong\u003eCO₂ monitoring\u003c\/strong\u003e, which can assist clinicians in monitoring ventilation and assessing parameters such as tube placement and metabolic stability.\u003c\/p\u003e\n\u003cp\u003eAs a refurbished medical device, the exact configuration, installed options, accessories, service history, calibration status, and functional condition should be confirmed before procurement and clinical use.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e✅ \u003cstrong\u003eRefurbished Dräger Evita XL Ventilator\u003c\/strong\u003e – Cost-effective option for healthcare facilities seeking refurbished critical-care equipment.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eAdult, Pediatric \u0026amp; Neonatal Support\u003c\/strong\u003e – Designed for ventilation across multiple patient age groups.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003ePremature Infant Support\u003c\/strong\u003e – NeoFlow option supports ventilation applications for premature infants.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eInvasive \u0026amp; Non-Invasive Ventilation\u003c\/strong\u003e – Provides both invasive and non-invasive respiratory support.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eMultiple Ventilation Modes\u003c\/strong\u003e – Includes IPPV, SIMV, MMV, BIPAP, CPAP\/ASB and APRV.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eNIV Plus\u003c\/strong\u003e – Provides mask ventilation with advanced leak compensation.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eAutoFlow Technology\u003c\/strong\u003e – Supports smooth ventilation and transitions toward spontaneous breathing.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003ePCV+ Capability\u003c\/strong\u003e – Included within the open breathing-system concept.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eIntegrated CO₂ Monitoring\u003c\/strong\u003e – Provides built-in monitoring of carbon dioxide.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eWide Ventilation Frequency Range\u003c\/strong\u003e – Up to 100 breaths\/min, with neonatal capability up to 150 breaths\/min according to the supplied specifications.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eFlexible Inspiratory Flow\u003c\/strong\u003e – Supports different flow ranges for adult, pediatric and neonatal applications.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eFast Valve Response\u003c\/strong\u003e – Valve response time specified at \u003cstrong\u003e≤5 ms\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e✅ \u003cstrong\u003eICU Application\u003c\/strong\u003e – Designed for intensive-care ventilation and long-term respiratory support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 99.941%; height: 372.282px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 48.6062%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 48.9749%; height: 19.5938px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eRefurbished Dräger Evita XL Ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eDräger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eEvita XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eICU Mechanical Ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eInvasive \u0026amp; Non-Invasive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003ePatient Groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eAdult, Pediatric \u0026amp; Neonatal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003ePremature Infant Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eNeoFlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation Frequency – Adult\/Pediatric\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003e0–100 breaths\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation Frequency – Neonatal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eUp to 150 breaths\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eInspiratory Flow – Adult\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003e6–120 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eInspiratory Flow – Pediatric\/Neonatal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003e6–30 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eValve Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003e≤5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eCO₂ Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eNIV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eNIV Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eIPPV, SIMV, MMV, BIPAP, CPAP\/ASB, APRV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eBreathing System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eOpen Breathing System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 48.6062%; height: 19.5938px;\"\u003e\u003cstrong\u003eAdvanced Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.9749%; height: 19.5938px;\"\u003eAutoFlow, PCV+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDräger Evita XL\u003c\/strong\u003e supports a range of ventilation modes, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIPPV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMMV\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBIPAP\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCPAP\/ASB\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAPRV\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe exact modes and options available on a refurbished unit should be verified according to its installed configuration.\u003c\/p\u003e\n\u003ch3\u003eNIV Plus \u0026amp; Leak Compensation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNIV Plus\u003c\/strong\u003e functionality provides mask-based non-invasive ventilation with advanced \u003cstrong\u003eleak compensation\u003c\/strong\u003e. This feature is intended to help maintain effective ventilation when using a non-invasive interface.\u003c\/p\u003e\n\u003ch3\u003eAutoFlow \u0026amp; PCV\u003cstrong\u003e+\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDräger Evita XL\u003c\/strong\u003e incorporates an open breathing system with \u003cstrong\u003eAutoFlow and PCV+ capabilities\u003c\/strong\u003e. According to the supplied information, these functions support smooth transitions toward spontaneous breathing.\u003c\/p\u003e\n\u003ch3\u003eCO₂ Monitoring\u003c\/h3\u003e\n\u003cp\u003eAn integrated \u003cstrong\u003eCO₂ monitoring system\u003c\/strong\u003e provides clinicians with additional respiratory information. The supplied product information identifies its use in assessing \u003cstrong\u003ecorrect tube placement and metabolic stability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003ePatient Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRefurbished Dräger Evita XL\u003c\/strong\u003e is designed for a broad patient population:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdult patients\u003c\/li\u003e\n\u003cli\u003ePediatric patients\u003c\/li\u003e\n\u003cli\u003eNeonatal patients\u003c\/li\u003e\n\u003cli\u003ePremature infants when equipped with the \u003cstrong\u003eNeoFlow option\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis broad patient range makes the Evita XL suitable for critical-care environments requiring flexible respiratory-support capabilities.\u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53189622399157,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Refurbished-Dr_ger-Evita-XL-ICU-Ventilator.jpg?v=1788156718","url":"https:\/\/healthyantrastore.com\/products\/drager-evita-xl-icu-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}