{"product_id":"drager-fabius-tiro-anesthesia-workstation","title":"Dräger Fabius Tiro Anesthesia Workstation","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eRefurbished Dräger Fabius Tiro\u003c\/strong\u003e is a compact, space-saving \u003cstrong\u003eanesthesia workstation\u003c\/strong\u003e designed for professional operating-room and anesthesia applications. It combines an electrically driven \u003cstrong\u003eE-Vent piston ventilator\u003c\/strong\u003e, integrated \u003cstrong\u003eCOSY breathing system\u003c\/strong\u003e, precision gas-delivery controls, vaporizer compatibility, and integrated respiratory monitoring in a flexible workstation configuration.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eE-Vent ventilator\u003c\/strong\u003e uses an electrically driven and electronically controlled piston mechanism that does not require drive gas, helping optimize the use of available gas supplies. The integrated \u003cstrong\u003eCOSY breathing system\u003c\/strong\u003e incorporates a CO₂ absorber and modular components designed for convenient handling and cleaning.\u003c\/p\u003e\n\u003cp\u003eThe gas supply system supports \u003cstrong\u003eO₂, N₂O and Air\u003c\/strong\u003e from either a central pipeline or backup cylinders. The workstation is compatible with \u003cstrong\u003eDräger Vapor series and Selectatec-compatible vaporizers\u003c\/strong\u003e, depending on the exact configuration.\u003c\/p\u003e\n\u003cp\u003eThe integrated monitoring display provides real-time information including \u003cstrong\u003eairway pressure, tidal volume, breathing frequency and inspiratory oxygen concentration (FiO₂)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAs a refurbished anesthesia workstation, the exact condition, installed options, ventilator configuration, vaporizer compatibility, battery condition, accessories and calibration status should be confirmed before procurement and clinical use.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e✅ \u003cstrong\u003eRefurbished Dräger Fabius Tiro Anesthesia Workstation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e✅ Compact, space-saving workstation design\u003c\/li\u003e\n\u003cli\u003e✅ Electrically driven \u003cstrong\u003eE-Vent piston ventilator\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e✅ Electronically controlled ventilation\u003c\/li\u003e\n\u003cli\u003e✅ Ventilator does not require drive gas\u003c\/li\u003e\n\u003cli\u003e✅ Integrated \u003cstrong\u003eCOSY breathing system\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e✅ Integrated CO₂ absorber\u003c\/li\u003e\n\u003cli\u003e✅ Modular breathing-system components\u003c\/li\u003e\n\u003cli\u003e✅ Supports O₂, N₂O and Air\u003c\/li\u003e\n\u003cli\u003e✅ Central pipeline and backup-cylinder gas supply\u003c\/li\u003e\n\u003cli\u003e✅ Dräger Vapor series vaporizer compatibility\u003c\/li\u003e\n\u003cli\u003e✅ Volume Control (VC \/ IPPV)\u003c\/li\u003e\n\u003cli\u003e✅ Pressure Control (PCV)\u003c\/li\u003e\n\u003cli\u003e✅ Pressure Support (PS)\u003c\/li\u003e\n\u003cli\u003e✅ SIMV \/ PS\u003c\/li\u003e\n\u003cli\u003e✅ Mobile trolley mounting\u003c\/li\u003e\n\u003cli\u003e✅ Wall-mount configuration\u003c\/li\u003e\n\u003cli\u003e✅ Ceiling-integration option\u003c\/li\u003e\n\u003cli\u003e✅ AC power operation\u003c\/li\u003e\n\u003cli\u003e✅ Internal battery backup\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eE-Vent Ventilator\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDräger Fabius Tiro\u003c\/strong\u003e incorporates an electrically driven, electronically controlled \u003cstrong\u003eE-Vent piston ventilator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike pneumatic drive systems, the E-Vent does not require a separate drive-gas supply. This design can help conserve available medical gas supplies and extend cylinder runtime in appropriate operating conditions.\u003c\/p\u003e\n\u003ch3\u003eCOSY Breathing System\u003c\/h3\u003e\n\u003cp\u003eThe integrated \u003cstrong\u003eCOSY breathing system\u003c\/strong\u003e is a compact breathing-system platform incorporating a \u003cstrong\u003eCO₂ absorber\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts modular construction is designed to facilitate handling, cleaning and routine maintenance of the breathing system.\u003c\/p\u003e\n\u003cp\u003eThe supplied specification indicates a CO₂ absorber capacity of approximately \u003cstrong\u003e1.5 litres\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGas Supply System\u003c\/h3\u003e\n\u003cp\u003eThe Fabius Tiro supports delivery of commonly used medical gases:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eOxygen (O₂)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNitrous Oxide (N₂O)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAir\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGas can be supplied through a central pipeline system or backup cylinders, depending on the installed configuration.\u003c\/p\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRefurbished Dräger Fabius Tiro\u003c\/strong\u003e supports the following ventilation modes:\u003c\/p\u003e\n\u003ch3\u003eManual \/ Spontaneous\u003c\/h3\u003e\n\u003cp\u003eAllows manual or spontaneous breathing operation according to the clinical setup.\u003c\/p\u003e\n\u003ch3\u003eVolume Control – VC \/ IPPV\u003c\/h3\u003e\n\u003cp\u003eProvides volume-controlled mandatory ventilation.\u003c\/p\u003e\n\u003ch3\u003ePressure Control – PCV\u003c\/h3\u003e\n\u003cp\u003eProvides pressure-controlled ventilation.\u003c\/p\u003e\n\u003ch3\u003ePressure Support – PS\u003c\/h3\u003e\n\u003cp\u003eProvides pressure-supported spontaneous breathing.\u003c\/p\u003e\n\u003ch3\u003eSIMV \/ PS\u003c\/h3\u003e\n\u003cp\u003eProvides synchronized intermittent mandatory ventilation with pressure-support capability.\u003c\/p\u003e\n\u003cp\u003eThe exact mode availability should be verified according to the specific refurbished configuration.\u003c\/p\u003e\n\u003ch3\u003ePower \u0026amp; Battery Backup\u003c\/h3\u003e\n\u003cp\u003eThe workstation operates from standard AC power.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003ePower Specification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMinimum 45 minutes up to 120 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO₂ Absorber Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eBattery runtime on a refurbished unit may vary depending on battery age, condition, workload and configuration.\u003c\/p\u003e\n\u003ch3\u003eMounting \u0026amp; Installation Options\u003c\/h3\u003e\n\u003cp\u003eThe Dräger Fabius Tiro offers flexible installation options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMobile trolley \/ cart\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWall mounting\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCeiling integration\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the platform adaptable to different operating-room and anesthesia-workstation layouts.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDräger Fabius Tiro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnesthesia Workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilator Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE-Vent Piston Ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilator Drive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrically Driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreathing System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOSY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO₂ Absorber\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO₂ Absorber Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eO₂, N₂O \u0026amp; Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGas Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral Pipeline \/ Backup Cylinders\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVaporizer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDräger Vapor \/ Selectatec-Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\/Spontaneous, VC\/IPPV, PCV, PS, SIMV\/PS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAirway Pressure, Tidal Volume, Frequency, FiO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45–120 Minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrolley, Wall Mount, Ceiling Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53197090783413,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Refurbished-Dr_ger-Fabius-Tiro-Anesthesia-Workstation.jpg?v=1788327134","url":"https:\/\/healthyantrastore.com\/products\/drager-fabius-tiro-anesthesia-workstation","provider":"Health Yantra Store","version":"1.0","type":"link"}