{"product_id":"drager-oxylog-2000-emergency-transport-ventilator","title":"Dräger Oxylog 2000 Emergency \u0026 Transport Ventilator","description":"\u003cp\u003eThe \u003cstrong\u003eDräger Oxylog 2000\u003c\/strong\u003e is a time-cycled, volume-constant emergency and transport ventilator designed for \u003cstrong\u003eadult and pediatric patients\u003c\/strong\u003e. This refurbished ventilator is intended for professional respiratory support during \u003cstrong\u003epre-hospital emergency care, intra-hospital patient movement, and road or air transport\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Oxylog 2000 provides controlled and synchronized ventilation through \u003cstrong\u003eIPPV, SIPPV and SIMV\u003c\/strong\u003e, along with \u003cstrong\u003eCPAP for spontaneous breathing\u003c\/strong\u003e. It also incorporates adjustable PEEP, oxygen concentration settings, airway-pressure monitoring, expiratory minute-volume monitoring, and built-in alarms for important operating conditions.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency \u0026amp; transport ventilation:\u003c\/strong\u003e Designed for mobile respiratory support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdult \u0026amp; pediatric application:\u003c\/strong\u003e Suitable for both patient groups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTime-cycled ventilation:\u003c\/strong\u003e Uses a time-cycled ventilation approach.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVolume-constant ventilation:\u003c\/strong\u003e Provides volume-constant mechanical ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple ventilation modes:\u003c\/strong\u003e IPPV, SIPPV, SIMV and CPAP.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable tidal volume:\u003c\/strong\u003e Approximately \u003cstrong\u003e100–1,500 mL\u003c\/strong\u003e, with configurations\/versions supporting up to \u003cstrong\u003e2,000 mL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable oxygen concentration:\u003c\/strong\u003e Approximately \u003cstrong\u003e60% or 100% oxygen\u003c\/strong\u003e, depending on configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated PEEP:\u003c\/strong\u003e Adjustable PEEP valve, typically \u003cstrong\u003e0–15 mbar\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable I:E ratio:\u003c\/strong\u003e Approximately \u003cstrong\u003e1:3 to 2:1\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirway-pressure monitoring:\u003c\/strong\u003e Pressure monitored using an analog gauge and digital display.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinute-volume monitoring:\u003c\/strong\u003e Tracks expiratory minute volume (MV).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in surveillance:\u003c\/strong\u003e Alerts for airway-pressure limits, power-supply failure and gas-supply disruption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 99.941%; height: 97.969px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 7.33775%; height: 19.5938px;\"\u003eMode\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 90.2434%; height: 19.5938px;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 7.33775%; height: 19.5938px;\"\u003e\u003cstrong\u003eIPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.2434%; height: 19.5938px;\"\u003eIntermittent Positive Pressure Ventilation for controlled mechanical ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 7.33775%; height: 19.5938px;\"\u003e\u003cstrong\u003eSIPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.2434%; height: 19.5938px;\"\u003eSynchronized Intermittent Positive Pressure Ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 7.33775%; height: 19.5938px;\"\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.2434%; height: 19.5938px;\"\u003eSynchronized Intermittent Mandatory Ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 7.33775%; height: 19.5938px;\"\u003e\u003cstrong\u003eCPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.2434%; height: 19.5938px;\"\u003eContinuous Positive Airway Pressure for spontaneous breathing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eTidal Volume \u0026amp; Oxygen Settings\u003c\/h3\u003e\n\u003cp\u003eThe Oxylog 2000 provides an adjustable tidal-volume range of approximately \u003cstrong\u003e100 mL to 1,500 mL\u003c\/strong\u003e, while some setups or versions may support volumes up to \u003cstrong\u003e2,000 mL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOxygen concentration can be configured to approximately \u003cstrong\u003e60 volume % or 100 volume %\u003c\/strong\u003e, depending on the particular version\/setup.\u003c\/p\u003e\n\u003cp\u003eBecause this is refurbished equipment, the exact available range should be verified against the specific unit before purchase.\u003c\/p\u003e\n\u003ch3\u003ePEEP \u0026amp; I:E Ratio\u003c\/h3\u003e\n\u003cp\u003eThe ventilator incorporates an \u003cstrong\u003eadjustable PEEP valve\u003c\/strong\u003e, with the supplied specifications indicating a typical range of \u003cstrong\u003e0–15 mbar\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe inspiratory-to-expiratory ratio can be adjusted approximately from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1:3\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThrough intermediate settings\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e2:1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMonitoring \u0026amp; Alarms\u003c\/h3\u003e\n\u003cp\u003eThe Oxylog 2000 provides basic monitoring and surveillance functions intended for emergency and transport ventilation.\u003c\/p\u003e\n\u003ch3\u003eAirway Pressure\u003c\/h3\u003e\n\u003cp\u003eAirway pressure is monitored using:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog pressure gauge\u003c\/li\u003e\n\u003cli\u003eDigital display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMinute Volume\u003c\/h3\u003e\n\u003cp\u003eThe ventilator tracks \u003cstrong\u003eexpiratory minute volume (MV)\u003c\/strong\u003e to provide information about delivered respiratory ventilation.\u003c\/p\u003e\n\u003ch3\u003eSurveillance \u0026amp; Alarms\u003c\/h3\u003e\n\u003cp\u003eThe built-in surveillance system provides alerts related to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAirway-pressure limits\u003c\/li\u003e\n\u003cli\u003ePower-supply failure\u003c\/li\u003e\n\u003cli\u003eGas-supply disruption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDräger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOxylog 2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency \u0026amp; transport ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTime-cycled, volume-constant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Population\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdult \u0026amp; pediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIPPV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTidal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100–1,500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Tidal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 2,000 mL depending on version\/setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOxygen Concentration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 60% or 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePEEP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 0–15 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI:E Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1:3 to 2:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirway Pressure Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog gauge + digital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinute Volume Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExpiratory MV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAirway pressure, power supply, gas supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePre-hospital, intra-hospital \u0026amp; transport\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53211724546229,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Dr_ger-Oxylog-2000-Refurbished-Ventilator.jpg?v=1788507943","url":"https:\/\/healthyantrastore.com\/products\/drager-oxylog-2000-emergency-transport-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}