{"product_id":"drager-oxylog-3000-plus-emergency-transport-ventilator","title":"Dräger Oxylog 3000 Plus Emergency \u0026 Transport Ventilator","description":"\u003cp\u003eThe \u003cstrong\u003eRefurbished Dräger Oxylog 3000 Plus\u003c\/strong\u003e is a versatile emergency and transport ventilator designed to support both \u003cstrong\u003einvasive ventilation and non-invasive ventilation (NIV)\u003c\/strong\u003e. It combines volume- and pressure-controlled ventilation modes with \u003cstrong\u003eintegrated leak compensation, AutoFlow functionality, apnea ventilation, and comprehensive respiratory monitoring\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003etidal volume range starting from 50 mL\u003c\/strong\u003e, the Oxylog 3000 Plus is suitable for a broad range of emergency, transport, and critical-care applications. Its compact design and intuitive rotary-control interface make it practical for use where reliable ventilation support is required.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRefurbished \u003cstrong\u003eDräger Oxylog 3000 Plus ventilator\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003eemergency and transport ventilation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003einvasive and non-invasive ventilation (NIV)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTidal volume starting from \u003cstrong\u003e50 mL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVolume-controlled and pressure-controlled ventilation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated leak compensation\u003c\/strong\u003e for NIV applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutoFlow\u003c\/strong\u003e for optimized gas flow and pressure delivery\u003c\/li\u003e\n\u003cli\u003eAdjustable \u003cstrong\u003etidal volume (VT), respiratory rate, PEEP, and inspiratory pressure\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApnea ventilation\u003c\/strong\u003e with automatic backup ventilation\u003c\/li\u003e\n\u003cli\u003eComprehensive airway-pressure and respiratory alarms\u003c\/li\u003e\n\u003cli\u003eDedicated parameter buttons and central rotary control\u003c\/li\u003e\n\u003cli\u003eDesigned for professional healthcare environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInvasive Ventilation Modes\u003c\/h3\u003e\n\u003cp\u003eThe refurbished Oxylog 3000 Plus supports several invasive ventilation configurations for controlled and assisted ventilation.\u003c\/p\u003e\n\u003ch3\u003eVC-CMV \/ VC-AC\u003c\/h3\u003e\n\u003cp\u003eVolume-controlled ventilation provides a target tidal volume with mandatory breaths delivered according to the configured respiratory parameters.\u003c\/p\u003e\n\u003ch3\u003eVC-SIMV\u003c\/h3\u003e\n\u003cp\u003eSynchronized intermittent mandatory ventilation combines mandatory volume-controlled breaths with spontaneous breathing between mandatory breaths.\u003c\/p\u003e\n\u003ch3\u003ePC-BIPAP \/ PC-SIMV+\u003c\/h3\u003e\n\u003cp\u003ePressure-controlled ventilation modes provide pressure-based respiratory support while allowing spontaneous breathing according to the selected configuration.\u003c\/p\u003e\n\u003ch3\u003eAutoFlow\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eNon-Invasive Ventilation (NIV)\u003c\/h3\u003e\n\u003cp\u003eThe Oxylog 3000 Plus can be configured for \u003cstrong\u003enon-invasive ventilation\u003c\/strong\u003e using an appropriate patient interface.\u003c\/p\u003e\n\u003ch3\u003eSPN CPAP \/ PS \/ NIV\u003c\/h3\u003e\n\u003cp\u003eNIV can be activated through the ventilator settings. When NIV is enabled, the ventilator applies dedicated leak compensation and adjusts relevant alarm behavior to account for intentional and unintentional mask leakage.\u003c\/p\u003e\n\u003ch3\u003eNIV Parameters\u003c\/h3\u003e\n\u003cp\u003eDepending on the selected configuration, clinicians can adjust:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePEEP\u003c\/li\u003e\n\u003cli\u003eTrigger sensitivity\u003c\/li\u003e\n\u003cli\u003ePressure Support \/ ASB\u003c\/li\u003e\n\u003cli\u003eSpontaneous breathing support\u003c\/li\u003e\n\u003cli\u003eNIV-related alarm parameters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe supplied information indicates a trigger sensitivity of approximately \u003cstrong\u003e3 L\/min as a default example\u003c\/strong\u003e, although actual settings may vary according to configuration and clinical requirements.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Leak Compensation\u003c\/h3\u003e\n\u003cp\u003eA major feature of the Oxylog 3000 Plus for NIV applications is its \u003cstrong\u003eintegrated leak compensation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMask leakage can interfere with pressure delivery and patient-triggering during non-invasive ventilation. The leak-compensation system helps the ventilator compensate for leakage and maintain more reliable pressure support.\u003c\/p\u003e\n\u003cp\u003eThis makes the unit suitable for applications where NIV is required during emergency care and patient transport.\u003c\/p\u003e\n\u003ch3\u003eSafety \u0026amp; Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe Oxylog 3000 Plus incorporates respiratory monitoring and alarm functions designed to alert clinicians to potentially significant changes in ventilation.\u003c\/p\u003e\n\u003ch3\u003eAlarm Monitoring Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh airway pressure\u003c\/li\u003e\n\u003cli\u003eLow airway pressure\u003c\/li\u003e\n\u003cli\u003eHigh respiratory rate\u003c\/li\u003e\n\u003cli\u003eApnea\u003c\/li\u003e\n\u003cli\u003ePatient disconnection\u003c\/li\u003e\n\u003cli\u003eHigh minute volume\u003c\/li\u003e\n\u003cli\u003eLow minute volume\u003c\/li\u003e\n\u003cli\u003eOther ventilation-related limit conditions depending on configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese alarms help clinicians identify changes in patient ventilation, circuit integrity, and respiratory performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDräger Oxylog 3000 Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency \u0026amp; transport ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInvasive \u0026amp; Non-Invasive (NIV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVolume-controlled \u0026amp; pressure-controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTidal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStarting from 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVC-CMV, VC-AC, VC-SIMV, PC-BIPAP, PC-SIMV+ and related configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutoFlow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNIV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLeak Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPN CPAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable in supported modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApnea Ventilation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic backup ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated parameter buttons + central rotary knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAirway pressure, respiratory rate, minute volume and ventilation parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure, apnea, disconnect, respiratory-rate and minute-volume alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition Assessment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefurbished and functionally checked before dispatch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53198448558261,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Refurbished-Dr_ger-Oxylog-3000-Plus-Ventilator.jpg?v=1788353431","url":"https:\/\/healthyantrastore.com\/products\/drager-oxylog-3000-plus-emergency-transport-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}