{"product_id":"drager-savina-300-intensive-care-ventilator","title":"Dräger Savina 300 Intensive Care Ventilator","description":"\u003cp\u003eThe \u003cstrong\u003eDräger Savina 300\u003c\/strong\u003e is an advanced \u003cstrong\u003eturbine-driven intensive care ventilator\u003c\/strong\u003e designed for adult and pediatric patients. It combines independent turbine-based gas generation with invasive and non-invasive ventilation, a responsive \u003cstrong\u003e12-inch color touchscreen\u003c\/strong\u003e, and battery-supported operation for greater flexibility in hospital and transport environments.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003erefurbished Dräger Savina 300 ventilator\u003c\/strong\u003e supports a broad range of volume-controlled, pressure-controlled and spontaneous ventilation modes. Advanced functions such as \u003cstrong\u003eAutoFlow\u003c\/strong\u003e and automatic leak compensation help support volume-constant ventilation and patient-ventilator synchrony during NIV.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine-driven ventilation:\u003c\/strong\u003e Built-in turbine generates ventilation gas flow without total reliance on a central gas pipeline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdult \u0026amp; pediatric support:\u003c\/strong\u003e Designed for both adult and pediatric patients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide tidal-volume range:\u003c\/strong\u003e Supports tidal volumes from \u003cstrong\u003e20 to 2,000 mL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh inspiratory flow:\u003c\/strong\u003e Maximum inspiratory flow of up to \u003cstrong\u003e250 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-inch color touchscreen:\u003c\/strong\u003e Responsive touchscreen provides an intuitive interface for clinical configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInvasive \u0026amp; non-invasive ventilation:\u003c\/strong\u003e Supports conventional invasive ventilation and \u003cstrong\u003eNIV\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutoFlow:\u003c\/strong\u003e Automatically adapts ventilation to support volume-constant ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic leak compensation:\u003c\/strong\u003e Helps compensate for leaks during non-invasive ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible oxygen supply:\u003c\/strong\u003e Supports \u003cstrong\u003ehigh-pressure oxygen (HPO)\u003c\/strong\u003e and \u003cstrong\u003elow-pressure oxygen (LPO)\u003c\/strong\u003e options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery backup:\u003c\/strong\u003e Internal and external batteries provide up to \u003cstrong\u003e5 hours\u003c\/strong\u003e of independent ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple ventilation modes:\u003c\/strong\u003e Includes volume-controlled, pressure-controlled and spontaneous breathing modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHospital \u0026amp; transport flexibility:\u003c\/strong\u003e Turbine-based operation and battery support provide greater independence from fixed gas and power infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTurbine-Driven Gas Generation\u003c\/h3\u003e\n\u003cp\u003eThe Savina 300 incorporates a \u003cstrong\u003ebuilt-in turbine\u003c\/strong\u003e for independent gas generation.\u003c\/p\u003e\n\u003cp\u003eThis design reduces reliance on a central gas pipeline system and provides greater flexibility for hospital applications where an independent flow source is beneficial.\u003c\/p\u003e\n\u003ch3\u003eKey turbine features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated turbine\u003c\/li\u003e\n\u003cli\u003eMaximum inspiratory flow up to \u003cstrong\u003e250 L\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndependent gas generation\u003c\/li\u003e\n\u003cli\u003eReduced reliance on central gas pipeline infrastructure\u003c\/li\u003e\n\u003cli\u003eSuitable for intensive-care applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003cp\u003eThe Savina 300 supports several categories of mechanical and spontaneous ventilation.\u003c\/p\u003e\n\u003ch3\u003eSpontaneous Breathing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSPN-CPAP\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAutoFlow\u003c\/h3\u003e\n\u003cp\u003eThe Savina 300 includes \u003cstrong\u003eAutoFlow\u003c\/strong\u003e, which provides automatic adaptation during volume-controlled ventilation.\u003c\/p\u003e\n\u003cp\u003eThis function is designed to help maintain a volume-constant ventilation strategy while adapting the delivery of inspiratory flow according to the selected ventilation requirements.\u003c\/p\u003e\n\u003ch3\u003eNIV \u0026amp; Automatic Leak Compensation\u003c\/h3\u003e\n\u003cp\u003eThe Savina 300 supports \u003cstrong\u003enon-invasive ventilation (NIV)\u003c\/strong\u003e and incorporates automatic leak compensation.\u003c\/p\u003e\n\u003cp\u003eDuring mask ventilation, leaks can affect triggering and patient-ventilator synchrony. The automatic leak-compensation function is designed to compensate for such leaks and support effective NIV operation.\u003c\/p\u003e\n\u003ch3\u003eOxygen Supply\u003c\/h3\u003e\n\u003cp\u003eThe Savina 300 supports two oxygen supply options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHPO — High-Pressure Oxygen\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLPO — Low-Pressure Oxygen\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe exact connection arrangement and oxygen-source requirements should be verified for the individual refurbished unit.\u003c\/p\u003e\n\u003ch3\u003eBattery \u0026amp; Transport Operation\u003c\/h3\u003e\n\u003cp\u003eThe ventilator uses \u003cstrong\u003einternal and external batteries\u003c\/strong\u003e, providing up to \u003cstrong\u003e5 hours of independent ventilation support\u003c\/strong\u003e according to the supplied specifications.\u003c\/p\u003e\n\u003cp\u003eActual operating time depends on battery condition, configuration and operating conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 99.941%; height: 509.439px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 45.5899%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" style=\"width: 51.9912%; height: 19.5938px;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eDräger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSavina 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eEquipment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eIntensive care ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePatient Population\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eAdult \u0026amp; pediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eVentilation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eTurbine-driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eTidal Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003e20–2,000 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Inspiratory Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eUp to 250 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eOxygen Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eHPO \u0026amp; LPO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003e12-inch responsive color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eVC-CMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eVC-AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eVC-SIMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eVC-MMV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePC-BIPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePC-AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePC-APRV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePC-B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eSPN-CPAP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutoFlow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eNIV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eAutomatic Leak Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eInternal + external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003eBattery Runtime\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eUp to 5 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 45.5899%; height: 19.5938px;\"\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.9912%; height: 19.5938px;\"\u003eIntensive care \u0026amp; hospital ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Drager","offers":[{"title":"Default Title","offer_id":53211926069429,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Dr_ger-Savina-300-Refurbished-Ventilator.jpg?v=1788517354","url":"https:\/\/healthyantrastore.com\/products\/drager-savina-300-intensive-care-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}