{"product_id":"hewlett-packard-codemaster-xl-m1722b-defibrillator-patient-monitor","title":"Hewlett-Packard CodeMaster XL+ M1722B Defibrillator \u0026 Patient Monitor","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eRefurbished Hewlett-Packard CodeMaster XL+ (Model M1722B)\u003c\/strong\u003e is a portable \u003cstrong\u003emonophasic defibrillator and patient monitor\u003c\/strong\u003e designed for emergency cardiac care. It provides selectable defibrillation energy up to \u003cstrong\u003e360 Joules\u003c\/strong\u003e, integrated ECG monitoring, synchronized cardioversion, event recording, and thermal strip recording.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe system combines defibrillation and cardiac monitoring functions in a portable platform intended for professional emergency and critical-care environments.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePortable monophasic defibrillator and patient monitor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSelectable defibrillation energy from \u003cstrong\u003e2–360 Joules\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDamped sinusoidal defibrillation waveform\u003c\/li\u003e\n\u003cli\u003eCharge time of \u003cstrong\u003eless than 5 seconds\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegrated ECG monitoring\u003c\/li\u003e\n\u003cli\u003eHeart-rate display range: \u003cstrong\u003e20–280 bpm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eECG acquisition through patient cables or paddles\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSynchronized cardioversion\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eManual R-wave synchronization\u003c\/li\u003e\n\u003cli\u003eVisual synchronization markers\u003c\/li\u003e\n\u003cli\u003eAudible confirmation beeps\u003c\/li\u003e\n\u003cli\u003eStandard adult \u003cstrong\u003eanterior\/anterior combo paddles\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in pediatric electrodes with slide-off mechanism\u003c\/li\u003e\n\u003cli\u003ePaddle-to-patient \u003cstrong\u003econtact quality indicator\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegrated thermal recorder\u003c\/li\u003e\n\u003cli\u003eReal-time or delayed ECG strip recording\u003c\/li\u003e\n\u003cli\u003eEvent markers and shock-delivery documentation\u003c\/li\u003e\n\u003cli\u003eAdjustable audible and visual heart-rate alarms\u003c\/li\u003e\n\u003cli\u003eLead-fault detection\u003c\/li\u003e\n\u003cli\u003eAC and rechargeable-battery operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDefibrillation System\u003c\/h3\u003e\n\u003cp\u003eThe CodeMaster XL+ provides \u003cstrong\u003emanual defibrillation\u003c\/strong\u003e with selectable energy levels from:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2 to 360 Joules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe system uses a \u003cstrong\u003edamped sinusoidal waveform\u003c\/strong\u003e and has a specified charge time of \u003cstrong\u003eunder 5 seconds\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEnergy selection should be performed according to the applicable clinical protocol and patient condition by appropriately trained healthcare professionals.\u003c\/p\u003e\n\u003ch3\u003eAdult \u0026amp; Pediatric Combo Paddles\u003c\/h3\u003e\n\u003cp\u003eThe system uses standard \u003cstrong\u003ecombo paddles\u003c\/strong\u003e with anterior\/anterior adult electrode plates.\u003c\/p\u003e\n\u003cp\u003eThe paddles incorporate a slide-off mechanism that exposes \u003cstrong\u003ebuilt-in pediatric electrodes\u003c\/strong\u003e, allowing the same paddle assembly to accommodate adult and pediatric applications.\u003c\/p\u003e\n\u003cp\u003eThe exact paddle condition is particularly important when purchasing a refurbished defibrillator and should be checked before clinical use.\u003c\/p\u003e\n\u003ch3\u003eIntegrated ECG Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe CodeMaster XL+ provides real-time ECG monitoring with a specified heart-rate display range of:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e20–280 bpm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eECG information can be acquired through:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatient ECG cables\u003c\/li\u003e\n\u003cli\u003eStandard defibrillator paddles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe monitor displays the patient's heart rate and ECG waveform for cardiac assessment.\u003c\/p\u003e\n\u003ch3\u003eSynchronized Cardioversion\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSynchronizer Mode\u003c\/strong\u003e allows manual \u003cstrong\u003eR-wave synchronized cardioversion\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe system provides:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eR-wave synchronization\u003c\/li\u003e\n\u003cli\u003eVisual synchronization markers\u003c\/li\u003e\n\u003cli\u003eAudible confirmation beeps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis function is intended for appropriately trained clinical personnel following established cardioversion protocols.\u003c\/p\u003e\n\u003ch3\u003ePaddle Contact Indicator\u003c\/h3\u003e\n\u003cp\u003eThe defibrillator includes a \u003cstrong\u003epaddle-to-patient skin contact quality indicator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis helps the operator assess whether appropriate paddle contact has been established before delivering a shock.\u003c\/p\u003e\n\u003cp\u003eProper electrode\/paddle placement and contact should always be confirmed according to the applicable clinical procedure.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Thermal Recorder\u003c\/h3\u003e\n\u003cp\u003eThe built-in thermal recorder can document ECG and event information.\u003c\/p\u003e\n\u003cp\u003eRecording capabilities include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReal-time ECG strips\u003c\/li\u003e\n\u003cli\u003eApproximately \u003cstrong\u003e6-second delayed ECG recording\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeart-rate information\u003c\/li\u003e\n\u003cli\u003eEvent markers\u003c\/li\u003e\n\u003cli\u003eShock-delivery details\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis provides a physical record of selected cardiac events during emergency treatment.\u003c\/p\u003e\n\u003ch3\u003eAlarm System\u003c\/h3\u003e\n\u003cp\u003eThe CodeMaster XL+ includes adjustable \u003cstrong\u003eaudible and visual alarms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAlarm functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable heart-rate limits\u003c\/li\u003e\n\u003cli\u003ePatient heart-rate alerts\u003c\/li\u003e\n\u003cli\u003eLead-fault detection\u003c\/li\u003e\n\u003cli\u003eAudible alarm notification\u003c\/li\u003e\n\u003cli\u003eVisual alarm notification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAC \u0026amp; Battery Power\u003c\/h3\u003e\n\u003cp\u003eThe system can operate using:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eAC line power: 100–230 VAC\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHigh-capacity rechargeable battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe battery provides portable operation and supports multiple defibrillation discharges, subject to battery condition and operating circumstances.\u003c\/p\u003e\n\u003cp\u003eFor a refurbished unit, battery charging, capacity, and discharge performance should be tested before clinical deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHewlett-Packard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCodeMaster XL+ M1722B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRefurbished\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefibrillator Type\u003c\/td\u003e\n\u003ctd\u003eMonophasic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd\u003eDamped sinusoidal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–360 J\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Energy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e360 J\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Time\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u0026lt;5 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG Monitoring\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeart Rate Range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20–280 bpm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eECG Acquisition\u003c\/td\u003e\n\u003ctd\u003ePatient cable or paddles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCardioversion\u003c\/td\u003e\n\u003ctd\u003eSynchronized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaddles\u003c\/td\u003e\n\u003ctd\u003eAdult anterior\/anterior combo paddles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePediatric Electrodes\u003c\/td\u003e\n\u003ctd\u003eBuilt into combo paddles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Indicator\u003c\/td\u003e\n\u003ctd\u003ePaddle-to-patient contact quality indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder\u003c\/td\u003e\n\u003ctd\u003eIntegrated thermal recorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003eReal-time \/ approximately 6-second delayed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent Recording\u003c\/td\u003e\n\u003ctd\u003eECG, heart rate, event markers, shock details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003eAdjustable audio\/visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLead Fault Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input\u003c\/td\u003e\n\u003ctd\u003e100–230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable high-capacity battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hewlett-Packard","offers":[{"title":"Default Title","offer_id":53232334799029,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/HP-CodeMaster-XL_Defibrillator.png?v=1788868337","url":"https:\/\/healthyantrastore.com\/products\/hewlett-packard-codemaster-xl-m1722b-defibrillator-patient-monitor","provider":"Health Yantra Store","version":"1.0","type":"link"}