{"product_id":"jmj-dexterous-anesthesia-workstation","title":"JMJ Dexterous Anesthesia Workstation","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eJMJ Medical Dexterous Anesthesia Workstation\u003c\/strong\u003e is a high-quality hospital anesthesia workstation designed to provide controlled anesthetic gas delivery and mechanical ventilation during surgical procedures. Manufactured in India using a combination of \u003cstrong\u003eplastic, metal, and rust-resistant fiber construction\u003c\/strong\u003e, the workstation is designed for durability, mobility, and routine operating-theatre use.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Dexterous features a \u003cstrong\u003e7-inch touchscreen display\u003c\/strong\u003e and supports multiple ventilation modes, including \u003cstrong\u003eCMV\/VC, CMV\/PC, ACV\/VC, ACV\/PC, SIMV\/VC, SIMV\/PC, and Manual\u003c\/strong\u003e. Its tidal volume can be adjusted from \u003cstrong\u003e20–1500 mL\u003c\/strong\u003e, with respiratory frequency from \u003cstrong\u003e1–60 bpm\u003c\/strong\u003e and PIP from \u003cstrong\u003e0–60 cmH₂O\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor anesthetic gas delivery, the workstation incorporates a \u003cstrong\u003e5-tube rotameter\u003c\/strong\u003e with 2 Oxygen, 2 Nitrous Oxide, and 1 Air flowmeters. It supports semi-open, semi-closed, and closed breathing systems and provides an \u003cstrong\u003eO₂ flush of 35–75 L\/min\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe workstation also includes multiple safety alarms, including high\/low pressure, patient disconnection, tidal-volume high\/low, FiO₂ failure\/low FiO₂, source failure, and oxygen-failure alarms. A rechargeable battery provides \u003cstrong\u003eup to 3 hours of backup\u003c\/strong\u003e, while large antistatic castor wheels and front brakes make the workstation convenient to move within the hospital.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced anesthesia workstation for hospital use\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e7-inch touchscreen display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCMV\/VC and CMV\/PC ventilation modes\u003c\/li\u003e\n\u003cli\u003eACV\/VC and ACV\/PC ventilation modes\u003c\/li\u003e\n\u003cli\u003eSIMV\/VC and SIMV\/PC ventilation modes\u003c\/li\u003e\n\u003cli\u003eManual ventilation mode\u003c\/li\u003e\n\u003cli\u003eTidal volume: \u003cstrong\u003e20–1500 mL\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRespiratory frequency: \u003cstrong\u003e1–60 bpm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ePIP: \u003cstrong\u003e0–60 cmH₂O\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e5-tube rotameter system\u003c\/li\u003e\n\u003cli\u003e2 × Oxygen, 2 × Nitrous Oxide, 1 × Air\u003c\/li\u003e\n\u003cli\u003eO₂ flush: \u003cstrong\u003e35–75 L\/min\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSemi-open, semi-closed, and closed systems\u003c\/li\u003e\n\u003cli\u003eOxygen failure audible and visual alarm\u003c\/li\u003e\n\u003cli\u003eMultiple pressure and ventilation alarms\u003c\/li\u003e\n\u003cli\u003eReverse-flow protection safety valve\u003c\/li\u003e\n\u003cli\u003eSpace for mounting two vaporizers\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e3 hours battery backup\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eRust-resistant fiber body\u003c\/li\u003e\n\u003cli\u003eTwo smooth-sliding storage drawers\u003c\/li\u003e\n\u003cli\u003eLarge antistatic castor wheels\u003c\/li\u003e\n\u003cli\u003eFront wheels with brakes\u003c\/li\u003e\n\u003cli\u003eMade in India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGas Supply \u0026amp; Connections\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlowmeter\u003c\/td\u003e\n\u003ctd\u003e5-Tube Rotameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e2 Tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrous Oxide\u003c\/td\u003e\n\u003ctd\u003e2 Tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir\u003c\/td\u003e\n\u003ctd\u003e1 Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO₂ Flush\u003c\/td\u003e\n\u003ctd\u003e35–75 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder Attachment\u003c\/td\u003e\n\u003ctd\u003e2 O₂ + 2 N₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipeline Attachment\u003c\/td\u003e\n\u003ctd\u003e2 O₂ + 1 N₂O + 1 Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Changeover\u003c\/td\u003e\n\u003ctd\u003eNitrous Oxide and Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreathing System\u003c\/td\u003e\n\u003ctd\u003eSemi-open \/ Semi-closed \/ Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVaporizer Provision\u003c\/td\u003e\n\u003ctd\u003eSpace for 2 Vaporizers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSafety Features\u003c\/h3\u003e\n\u003cp\u003eThe Dexterous incorporates safety features designed to alert the operator to important ventilation and gas-supply conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-pressure alarm\u003c\/li\u003e\n\u003cli\u003eLow-pressure alarm\u003c\/li\u003e\n\u003cli\u003ePatient-disconnect alarm\u003c\/li\u003e\n\u003cli\u003eHigh\/low tidal-volume alarm\u003c\/li\u003e\n\u003cli\u003eFiO₂ failure alarm\u003c\/li\u003e\n\u003cli\u003eLow FiO₂ alarm\u003c\/li\u003e\n\u003cli\u003eSource-failure alarm\u003c\/li\u003e\n\u003cli\u003eOxygen-failure audible and visual alarm\u003c\/li\u003e\n\u003cli\u003eReverse-flow protection valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eJMJ Medical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDexterous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnesthesia Workstation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHospital\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7-inch Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation Modes\u003c\/td\u003e\n\u003ctd\u003eCMV\/VC, CMV\/PC, ACV\/VC, ACV\/PC, SIMV\/VC, SIMV\/PC, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTidal Volume\u003c\/td\u003e\n\u003ctd\u003e20–1500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e1–60 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI:E Ratio\u003c\/td\u003e\n\u003ctd\u003e1:9–4:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePIP\u003c\/td\u003e\n\u003ctd\u003e0–60 cmH₂O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eAC 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eUp to 3 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Level\u003c\/td\u003e\n\u003ctd\u003eHigh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ePlastic \/ Metal \/ Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody\u003c\/td\u003e\n\u003ctd\u003eRust-Proof Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e2 Drawers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMobility\u003c\/td\u003e\n\u003ctd\u003eLarge Antistatic Castor Wheels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Wheels\u003c\/td\u003e\n\u003ctd\u003eBraked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eBenefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated ventilation and anesthetic gas delivery\u003c\/li\u003e\n\u003cli\u003eMultiple ventilation modes for clinical flexibility\u003c\/li\u003e\n\u003cli\u003eWide tidal-volume and respiratory-frequency ranges\u003c\/li\u003e\n\u003cli\u003eFive-tube rotameter supports O₂, N₂O, and Air\u003c\/li\u003e\n\u003cli\u003eMultiple safety alarms for ventilation and gas-supply conditions\u003c\/li\u003e\n\u003cli\u003eBattery backup supports operation during temporary power interruptions\u003c\/li\u003e\n\u003cli\u003eLarge wheels allow easy movement within the OT\u003c\/li\u003e\n\u003cli\u003eTwo drawers provide convenient accessory storage\u003c\/li\u003e\n\u003cli\u003eTwo-vaporizer mounting provision\u003c\/li\u003e\n\u003cli\u003eDurable rust-resistant construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJMJ Medical Dexterous Anesthesia Workstation\u003c\/li\u003e\n\u003cli\u003eIntegrated anesthesia ventilator\u003c\/li\u003e\n\u003cli\u003e5-tube rotameter assembly\u003c\/li\u003e\n\u003cli\u003eCylinder connection system\u003c\/li\u003e\n\u003cli\u003ePipeline connection system\u003c\/li\u003e\n\u003cli\u003eVaporizer mounting provision\u003c\/li\u003e\n\u003cli\u003eBreathing-system connection\u003c\/li\u003e\n\u003cli\u003eTrolley with castor wheels and brakes\u003c\/li\u003e\n\u003cli\u003eStorage drawers\u003c\/li\u003e\n\u003cli\u003e\n\u003ch4\u003eBuilt-in rechargeable battery\u003c\/h4\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer: \u003c\/strong\u003eContent is reviewed by our Biomedical Product Expert and verified against available manufacturer documentation. Specifications may vary by model or batch. Use the equipment strictly as directed by the manufacturer. This information is for general product guidance only and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"JMJ Medical","offers":[{"title":"Default Title","offer_id":52962360197301,"sku":null,"price":550000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/JMJ-Dexterous-Anesthesia-Workstation.jpg?v=1786521449","url":"https:\/\/healthyantrastore.com\/products\/jmj-dexterous-anesthesia-workstation","provider":"Health Yantra Store","version":"1.0","type":"link"}