{"product_id":"konica-minolta-regius-sigma-ii-cr-system","title":"Konica Minolta Regius Sigma II CR System","description":"\u003cp\u003eThe \u003cstrong\u003eRefurbished Konica Minolta Regius Sigma II\u003c\/strong\u003e is an ultra-compact \u003cstrong\u003eComputed Radiography (CR) digital X-ray image reader\u003c\/strong\u003e designed for clinics, small hospitals, emergency rooms, and other healthcare facilities requiring a space-efficient digital radiography workflow.\u003c\/p\u003e\n\u003cp\u003eThe Regius Sigma II combines a compact desktop design with selectable image resolution and efficient plate processing. With processing speeds of \u003cstrong\u003eup to 60 imaging plates per hour\u003c\/strong\u003e, it can support routine radiographic workflows while occupying a relatively small footprint.\u003c\/p\u003e\n\u003cp\u003eThe system supports \u003cstrong\u003e87.5 µm high-detail resolution\u003c\/strong\u003e and \u003cstrong\u003e175 µm general-purpose resolution\u003c\/strong\u003e, with \u003cstrong\u003e12-bit digital gradation providing 4,096 grayscale levels\u003c\/strong\u003e. Its compatibility with REGIUS image plates and RC-300 cassettes allows it to be incorporated into suitable CR-based X-ray workflows.\u003c\/p\u003e\n\u003cp\u003eAn integrated console workstation can support \u003cstrong\u003eimage acquisition, image processing, and DICOM transfer\u003c\/strong\u003e, allowing the CR reader to connect with compatible digital imaging and hospital information workflows.\u003c\/p\u003e\n\u003cp\u003eAs a refurbished CR system, the exact condition, plate\/cassette compatibility, software version, workstation configuration, and included accessories should be verified before purchase.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Compact CR Design:\u003c\/strong\u003e Desktop\/portable-use mono-slot configuration for space-constrained facilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLightweight Construction:\u003c\/strong\u003e Approximate system weight of \u003cstrong\u003e28 kg\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall Footprint:\u003c\/strong\u003e Approximately \u003cstrong\u003e510 × 610 × 355 mm\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Processing Capacity:\u003c\/strong\u003e Up to \u003cstrong\u003e60 plates per hour\u003c\/strong\u003e, with selectable 25, 45, or 60 plates\/hour options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Detail Resolution:\u003c\/strong\u003e Selectable \u003cstrong\u003e87.5 µm\u003c\/strong\u003e resolution for detailed imaging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Resolution:\u003c\/strong\u003e \u003cstrong\u003e175 µm\u003c\/strong\u003e selectable resolution for general radiographic applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Bit Digital Gradation:\u003c\/strong\u003e Provides \u003cstrong\u003e4,096 grayscale levels\u003c\/strong\u003e for digital image processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREGIUS Plate Compatibility:\u003c\/strong\u003e Designed for use with \u003cstrong\u003eREGIUS Plate FP-1S\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Cassette Sizes:\u003c\/strong\u003e Compatible with REGIUS Cassette RC-300 supporting multiple formats.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDICOM Workflow:\u003c\/strong\u003e Integrated workstation software supports image acquisition, processing, and DICOM transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy-Efficient Operation:\u003c\/strong\u003e Approximately \u003cstrong\u003e100 VA during operation\u003c\/strong\u003e and \u003cstrong\u003e20 VA in idle mode\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefurbished \u0026amp; Tested:\u003c\/strong\u003e A cost-effective option for healthcare facilities seeking a professional CR imaging solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComputed Radiography Image Reader\u003c\/h3\u003e\n\u003cp\u003eThe Regius Sigma II is a \u003cstrong\u003eCR image reader\u003c\/strong\u003e, meaning it digitizes X-ray images recorded on compatible imaging plates. This allows facilities using conventional X-ray equipment to incorporate digital image processing and networking into their radiography workflow.\u003c\/p\u003e\n\u003cp\u003eThe compact design makes it particularly suitable for environments where installation space is limited.\u003c\/p\u003e\n\u003ch2\u003eCompact Desktop Design\u003c\/h2\u003e\n\u003cp\u003eThe system measures approximately \u003cstrong\u003e510 × 610 × 355 mm\u003c\/strong\u003e and weighs around \u003cstrong\u003e28 kg\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts ultra-compact footprint of approximately \u003cstrong\u003e0.31 m²\u003c\/strong\u003e makes it suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSmall radiology departments\u003c\/li\u003e\n\u003cli\u003eClinics\u003c\/li\u003e\n\u003cli\u003eEmergency rooms\u003c\/li\u003e\n\u003cli\u003eSmall hospitals\u003c\/li\u003e\n\u003cli\u003eMobile or space-constrained imaging environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe system's exact portability and installation requirements should be evaluated according to the intended clinical setup.\u003c\/p\u003e\n\u003ch2\u003eProcessing Speed\u003c\/h2\u003e\n\u003cp\u003eThe Regius Sigma II offers selectable processing-speed configurations:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eProcessing Option\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eCapacity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Option\u003c\/td\u003e\n\u003ctd\u003e25 plates\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigher-Speed Option\u003c\/td\u003e\n\u003ctd\u003e45 plates\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Stated Speed\u003c\/td\u003e\n\u003ctd\u003e60 plates\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe maximum stated throughput is \u003cstrong\u003eup to 60 imaging plates per hour\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eActual throughput can depend on workflow, plate size, image-processing settings, operator handling, and system configuration.\u003c\/p\u003e\n\u003ch3\u003eSelectable Image Resolution\u003c\/h3\u003e\n\u003cp\u003eThe CR reader provides two selectable resolution settings:\u003c\/p\u003e\n\u003ch3\u003e87.5 µm\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e87.5 µm\u003c\/strong\u003e setting is intended for high-detail image acquisition where greater spatial detail is required.\u003c\/p\u003e\n\u003ch3\u003e175 µm\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e175 µm\u003c\/strong\u003e setting is intended for general radiographic imaging applications where routine image acquisition is required.\u003c\/p\u003e\n\u003cp\u003eThe appropriate resolution should be selected according to the examination and clinical imaging requirements.\u003c\/p\u003e\n\u003ch3\u003e12-Bit Digital Gradation\u003c\/h3\u003e\n\u003cp\u003eThe Regius Sigma II uses \u003cstrong\u003e12-bit digital gradation\u003c\/strong\u003e, providing \u003cstrong\u003e4,096 grayscale levels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis digital gradation supports image processing across a broad range of grayscale values and helps the workstation generate diagnostically useful digital images from compatible CR plates.\u003c\/p\u003e\n\u003ch3\u003eIntegrated CR Workstation \u0026amp; DICOM\u003c\/h3\u003e\n\u003cp\u003eThe system includes console workstation software designed to support:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImage acquisition\u003c\/li\u003e\n\u003cli\u003eImage processing\u003c\/li\u003e\n\u003cli\u003eDigital image workflow\u003c\/li\u003e\n\u003cli\u003eDICOM transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis allows compatible images to be transferred into suitable healthcare imaging environments.\u003c\/p\u003e\n\u003cp\u003eThe actual DICOM configuration, workstation hardware, software version, network interface, and compatibility with an existing PACS should be verified before installation.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe Refurbished Konica Minolta Regius Sigma II can be used in suitable CR-based digital radiography workflows for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral X-ray imaging\u003c\/li\u003e\n\u003cli\u003eOutpatient radiography\u003c\/li\u003e\n\u003cli\u003eEmergency-room imaging\u003c\/li\u003e\n\u003cli\u003eClinic-based radiography\u003c\/li\u003e\n\u003cli\u003eSmall hospital radiology departments\u003c\/li\u003e\n\u003cli\u003eOrthopedic imaging workflows\u003c\/li\u003e\n\u003cli\u003eRoutine diagnostic radiography\u003c\/li\u003e\n\u003cli\u003eDigital image acquisition and DICOM transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual clinical applications depend on the X-ray equipment, image plates, software, installation, and applicable regulatory requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eKonica Minolta Regius Sigma II\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eComputed Radiography (CR) Image Reader\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eUltra-compact desktop \/ portable-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReader Configuration\u003c\/td\u003e\n\u003ctd\u003eMono-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e510 × 610 × 355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Footprint\u003c\/td\u003e\n\u003ctd\u003e0.31 m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Processing Speed\u003c\/td\u003e\n\u003ctd\u003eUp to 60 plates\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Processing Speeds\u003c\/td\u003e\n\u003ctd\u003e25 \/ 45 \/ 60 plates\/hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Detail Resolution\u003c\/td\u003e\n\u003ctd\u003e87.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Resolution\u003c\/td\u003e\n\u003ctd\u003e175 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Gradation\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrayscale Levels\u003c\/td\u003e\n\u003ctd\u003e4,096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Plate\u003c\/td\u003e\n\u003ctd\u003eREGIUS Plate FP-1S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCassette\u003c\/td\u003e\n\u003ctd\u003eREGIUS Cassette RC-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Cassette Formats\u003c\/td\u003e\n\u003ctd\u003e14×17\", 14×14\", 11×14\", 10×12\", 8×10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eIntegrated console workstation software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Functions\u003c\/td\u003e\n\u003ctd\u003eAcquisition \u0026amp; processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Function\u003c\/td\u003e\n\u003ctd\u003eDICOM transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption – Operating\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption – Idle\u003c\/td\u003e\n\u003ctd\u003e20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Konica Minolta","offers":[{"title":"Default Title","offer_id":53224947122357,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Refurbished-Konica-Minolta-Regius-Sigma-II-CR-Reader.jpg?v=1788778725","url":"https:\/\/healthyantrastore.com\/products\/konica-minolta-regius-sigma-ii-cr-system","provider":"Health Yantra Store","version":"1.0","type":"link"}