{"product_id":"maestros-ctg-150-fetal-maternal-monitor","title":"Maestros CTG 150 Fetal \u0026 Maternal Monitor","description":"\u003cp dir=\"auto\" data-start=\"45\" data-end=\"262\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"49\" data-end=\"69\"\u003eMaestros CTG 150\u003c\/strong\u003e is an advanced \u003cstrong data-start=\"85\" data-end=\"115\"\u003efetal and maternal monitor\u003c\/strong\u003e designed for comprehensive fetal monitoring with a \u003cstrong data-start=\"167\" data-end=\"219\"\u003etiltable 10.1-inch color TFT touchscreen display\u003c\/strong\u003e and built-in twin monitoring capabilities.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"264\" data-end=\"537\"\u003eIt supports \u003cstrong data-start=\"276\" data-end=\"326\"\u003edual-channel Fetal Heart Rate (FHR) monitoring\u003c\/strong\u003e, uterine activity monitoring through TOCO, automatic fetal movement detection, and automated CTG analysis scoring. Optional maternal \u003cstrong data-start=\"460\" data-end=\"477\"\u003eSpO₂ and NIBP\u003c\/strong\u003e monitoring can extend its maternal monitoring capabilities.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"539\" data-end=\"556\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"558\" data-end=\"1576\"\u003e\n\u003cli data-section-id=\"gu5f54\" data-start=\"558\" data-end=\"650\"\u003e\n\u003cstrong data-start=\"560\" data-end=\"595\"\u003e10.1-Inch Color TFT Touchscreen\u003c\/strong\u003e – High-resolution tiltable display with touch support.\u003c\/li\u003e\n\u003cli data-section-id=\"ok4fbp\" data-start=\"651\" data-end=\"745\"\u003e\n\u003cstrong data-start=\"653\" data-end=\"678\"\u003eTwin Fetal Monitoring\u003c\/strong\u003e – Dual-channel FHR monitoring with separate traces for each fetus.\u003c\/li\u003e\n\u003cli data-section-id=\"8pzkbx\" data-start=\"746\" data-end=\"845\"\u003e\n\u003cstrong data-start=\"748\" data-end=\"781\"\u003ePulsed Doppler FHR Monitoring\u003c\/strong\u003e – Uses pulsed Doppler with autocorrelation for FHR measurement.\u003c\/li\u003e\n\u003cli data-section-id=\"1mna9fo\" data-start=\"846\" data-end=\"926\"\u003e\n\u003cstrong data-start=\"848\" data-end=\"867\"\u003eTOCO Monitoring\u003c\/strong\u003e – Strain gauge technology for monitoring uterine activity.\u003c\/li\u003e\n\u003cli data-section-id=\"qs40m0\" data-start=\"927\" data-end=\"1018\"\u003e\n\u003cstrong data-start=\"929\" data-end=\"967\"\u003eAutomatic Fetal Movement Detection\u003c\/strong\u003e – Supports automated detection of fetal movements.\u003c\/li\u003e\n\u003cli data-section-id=\"cgwimp\" data-start=\"1019\" data-end=\"1097\"\u003e\n\u003cstrong data-start=\"1021\" data-end=\"1047\"\u003eAutomated CTG Analysis\u003c\/strong\u003e – Built-in automated CTG analysis scoring system.\u003c\/li\u003e\n\u003cli data-section-id=\"18uv9ro\" data-start=\"1098\" data-end=\"1187\"\u003e\n\u003cstrong data-start=\"1100\" data-end=\"1126\"\u003e150 mm Thermal Printer\u003c\/strong\u003e – Built-in high-resolution, long-life thermal array printer.\u003c\/li\u003e\n\u003cli data-section-id=\"khazng\" data-start=\"1188\" data-end=\"1289\"\u003e\n\u003cstrong data-start=\"1190\" data-end=\"1216\"\u003eOptional Maternal SpO₂\u003c\/strong\u003e – Supports maternal oxygen saturation monitoring as an optional feature.\u003c\/li\u003e\n\u003cli data-section-id=\"y7b8n1\" data-start=\"1290\" data-end=\"1392\"\u003e\n\u003cstrong data-start=\"1292\" data-end=\"1318\"\u003eOptional Maternal NIBP\u003c\/strong\u003e – Non-invasive blood pressure monitoring available as an optional add-on.\u003c\/li\u003e\n\u003cli data-section-id=\"1j5po5z\" data-start=\"1393\" data-end=\"1493\"\u003e\n\u003cstrong data-start=\"1395\" data-end=\"1427\"\u003e24-Hour Patient Data Storage\u003c\/strong\u003e – Supports storage of patient monitoring data for up to 24 hours.\u003c\/li\u003e\n\u003cli data-section-id=\"inbgaj\" data-start=\"1494\" data-end=\"1576\"\u003e\n\u003cstrong data-start=\"1496\" data-end=\"1520\"\u003eConnectivity Options\u003c\/strong\u003e – Supports PC\/server and wireless connectivity options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"iuhk0e\" dir=\"auto\" data-start=\"1583\" data-end=\"1601\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1603\" data-end=\"1733\"\u003eThe \u003cstrong data-start=\"1607\" data-end=\"1627\"\u003eMaestros CTG 150\u003c\/strong\u003e is a fetal and maternal monitoring system designed for \u003cstrong data-start=\"1683\" data-end=\"1709\"\u003ecardiotocography (CTG)\u003c\/strong\u003e and fetal surveillance.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1735\" data-end=\"1931\"\u003eThe system combines fetal heart rate monitoring, uterine activity monitoring, fetal movement detection, CTG analysis, data storage, and integrated thermal printing in a single monitoring platform.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1933\" data-end=\"2050\"\u003eIts \u003cstrong data-start=\"1937\" data-end=\"1967\"\u003etwin monitoring capability\u003c\/strong\u003e allows dual-channel FHR monitoring, with separate traces available for each fetus.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19048n\" dir=\"auto\" data-start=\"2057\" data-end=\"2095\"\u003e10.1-Inch Tiltable Color TFT Display\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2097\" data-end=\"2120\"\u003eThe CTG 150 features a:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2122\" data-end=\"2182\"\u003e\u003cstrong data-start=\"2122\" data-end=\"2182\"\u003e10.1-inch high-resolution tiltable color TFT touchscreen\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2184\" data-end=\"2305\"\u003eThe display is designed to provide clear visualization of fetal monitoring information and support touchscreen operation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"uv0waj\" dir=\"auto\" data-start=\"2307\" data-end=\"2327\"\u003eDisplay Features\u003c\/h3\u003e\n\u003cul data-start=\"2329\" data-end=\"2427\"\u003e\n\u003cli data-section-id=\"11p2prv\" data-start=\"2329\" data-end=\"2347\"\u003e10.1-inch screen\u003c\/li\u003e\n\u003cli data-section-id=\"spunm1\" data-start=\"2348\" data-end=\"2367\"\u003eColor TFT display\u003c\/li\u003e\n\u003cli data-section-id=\"13rg3rz\" data-start=\"2368\" data-end=\"2393\"\u003eHigh-resolution display\u003c\/li\u003e\n\u003cli data-section-id=\"1bn07p1\" data-start=\"2394\" data-end=\"2411\"\u003eTiltable design\u003c\/li\u003e\n\u003cli data-section-id=\"1rd9vya\" data-start=\"2412\" data-end=\"2427\"\u003eTouch support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1cjjigs\" dir=\"auto\" data-start=\"2434\" data-end=\"2468\"\u003eTwin Fetal Heart Rate Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2470\" data-end=\"2566\"\u003eThe Maestros CTG 150 supports \u003cstrong data-start=\"2500\" data-end=\"2544\"\u003edual-channel Fetal Heart Rate monitoring\u003c\/strong\u003e for twin pregnancies.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2568\" data-end=\"2588\"\u003eThe system provides:\u003c\/p\u003e\n\u003cul data-start=\"2590\" data-end=\"2721\"\u003e\n\u003cli data-section-id=\"y4y1ca\" data-start=\"2590\" data-end=\"2619\"\u003eDual-channel FHR monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"c5br2e\" data-start=\"2620\" data-end=\"2656\"\u003eSeparate FHR traces for each fetus\u003c\/li\u003e\n\u003cli data-section-id=\"ikhzgl\" data-start=\"2657\" data-end=\"2684\"\u003ePulsed Doppler technology\u003c\/li\u003e\n\u003cli data-section-id=\"1o62pis\" data-start=\"2685\" data-end=\"2721\"\u003eAutocorrelation for FHR monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2723\" data-end=\"2823\"\u003eThis allows the system to monitor the heart rates of two fetuses using separate monitoring channels.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1qbul08\" dir=\"auto\" data-start=\"2830\" data-end=\"2859\"\u003eFetal Heart Rate Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2861\" data-end=\"2937\"\u003eFetal heart rate is monitored using \u003cstrong data-start=\"2897\" data-end=\"2936\"\u003epulsed Doppler with autocorrelation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2939\" data-end=\"3057\"\u003eThe system is designed to provide continuous FHR monitoring and graphical trace presentation on the color TFT display.\u003c\/p\u003e\n\u003ch3 data-section-id=\"wezt7\" dir=\"auto\" data-start=\"3064\" data-end=\"3100\"\u003eUterine Activity \/ TOCO Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3102\" data-end=\"3170\"\u003eThe CTG 150 uses a \u003cstrong data-start=\"3121\" data-end=\"3137\"\u003estrain gauge\u003c\/strong\u003e for monitoring uterine activity.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3172\" data-end=\"3283\"\u003eThe TOCO channel provides a graphical representation of uterine activity alongside the fetal heart rate traces.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nn49yl\" dir=\"auto\" data-start=\"3290\" data-end=\"3326\"\u003eAutomatic Fetal Movement Detection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3328\" data-end=\"3387\"\u003eThe system includes \u003cstrong data-start=\"3348\" data-end=\"3386\"\u003eautomatic fetal movement detection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3389\" data-end=\"3501\"\u003eThis functionality allows fetal movements to be automatically detected as part of the fetal monitoring workflow.\u003c\/p\u003e\n\u003ch3 data-section-id=\"kl466q\" dir=\"auto\" data-start=\"3508\" data-end=\"3532\"\u003eAutomated CTG Analysis\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3534\" data-end=\"3604\"\u003eThe CTG 150 incorporates an \u003cstrong data-start=\"3562\" data-end=\"3603\"\u003eautomated CTG analysis scoring system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3606\" data-end=\"3677\"\u003eThis provides automated analysis of the recorded cardiotocography data.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3679\" data-end=\"3819\"\u003eThe supplied information does not specify the particular scoring methodology, algorithm, interpretation criteria, or output classifications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1f0jh03\" dir=\"auto\" data-start=\"3826\" data-end=\"3859\"\u003eBuilt-In 150 mm Thermal Printer\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3861\" data-end=\"3896\"\u003eThe CTG 150 features an integrated:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3898\" data-end=\"3957\"\u003e\u003cstrong data-start=\"3898\" data-end=\"3957\"\u003e150 mm high-resolution, long-life thermal array printer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3959\" data-end=\"4090\"\u003eThe built-in printer allows fetal monitoring traces and associated information to be printed for documentation and clinical review.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ut02fb\" dir=\"auto\" data-start=\"4092\" data-end=\"4112\"\u003ePrinter Features\u003c\/h3\u003e\n\u003cul data-start=\"4114\" data-end=\"4241\"\u003e\n\u003cli data-section-id=\"17uycnf\" data-start=\"4114\" data-end=\"4137\"\u003e150 mm printing width\u003c\/li\u003e\n\u003cli data-section-id=\"hs3qm7\" data-start=\"4138\" data-end=\"4172\"\u003eHigh-resolution thermal printing\u003c\/li\u003e\n\u003cli data-section-id=\"szh2hp\" data-start=\"4173\" data-end=\"4206\"\u003eLong-life thermal array printer\u003c\/li\u003e\n\u003cli data-section-id=\"1y9igzm\" data-start=\"4207\" data-end=\"4241\"\u003eBuilt into the monitoring system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1cd68so\" dir=\"auto\" data-start=\"4248\" data-end=\"4278\"\u003eOptional Maternal Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4280\" data-end=\"4357\"\u003eThe CTG 150 can be configured with optional maternal monitoring capabilities.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hv1yiu\" dir=\"auto\" data-start=\"4359\" data-end=\"4376\"\u003eOptional SpO₂\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4378\" data-end=\"4443\"\u003e\u003cstrong data-start=\"4378\" data-end=\"4406\"\u003eMaternal SpO₂ monitoring\u003c\/strong\u003e can be added as an optional feature.\u003c\/p\u003e\n\u003ch3 data-section-id=\"huiwjh\" dir=\"auto\" data-start=\"4445\" data-end=\"4462\"\u003eOptional NIBP\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4464\" data-end=\"4563\"\u003e\u003cstrong data-start=\"4464\" data-end=\"4511\"\u003eMaternal NIBP (Non-Invasive Blood Pressure)\u003c\/strong\u003e monitoring is also available as an optional add-on.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4565\" data-end=\"4669\"\u003eThese options allow the system to combine fetal monitoring with selected maternal vital-sign monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"ndfjfj\" dir=\"auto\" data-start=\"4676\" data-end=\"4713\"\u003ePatient Data Storage \u0026amp; Connectivity\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4715\" data-end=\"4736\"\u003eThe CTG 150 supports:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4738\" data-end=\"4780\"\u003e\u003cstrong data-start=\"4738\" data-end=\"4780\"\u003eUp to 24 hours of patient data storage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"4782\" data-end=\"4824\"\u003eIt also provides connectivity options for:\u003c\/p\u003e\n\u003cul data-start=\"4826\" data-end=\"4889\"\u003e\n\u003cli data-section-id=\"1qeq24e\" data-start=\"4826\" data-end=\"4843\"\u003ePC connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"1qclwp4\" data-start=\"4844\" data-end=\"4865\"\u003eServer connectivity\u003c\/li\u003e\n\u003cli data-section-id=\"lxnfal\" data-start=\"4866\" data-end=\"4889\"\u003eWireless connectivity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"4891\" data-end=\"5043\"\u003eThe specific communication protocols, wireless standards, server architecture, and data transfer formats were not specified in the supplied information.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1m9gx28\" dir=\"auto\" data-start=\"5050\" data-end=\"5073\"\u003eClinical Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"5075\" data-end=\"5166\"\u003eThe Maestros CTG 150 is designed for fetal and maternal monitoring applications, including:\u003c\/p\u003e\n\u003cul data-start=\"5168\" data-end=\"5385\"\u003e\n\u003cli data-section-id=\"1n1oxva\" data-start=\"5168\" data-end=\"5197\"\u003eFetal heart rate monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1lpwsoq\" data-start=\"5198\" data-end=\"5221\"\u003eTwin fetal monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"yqqxqh\" data-start=\"5222\" data-end=\"5246\"\u003eCardiotocography (CTG)\u003c\/li\u003e\n\u003cli data-section-id=\"10quyzh\" data-start=\"5247\" data-end=\"5276\"\u003eUterine activity monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"bbyx31\" data-start=\"5277\" data-end=\"5304\"\u003eFetal movement monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1g71y1g\" data-start=\"5305\" data-end=\"5354\"\u003eMaternal monitoring with optional SpO₂ and NIBP\u003c\/li\u003e\n\u003cli data-section-id=\"rs0tx9\" data-start=\"5355\" data-end=\"5385\"\u003eAntenatal fetal surveillance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"5387\" data-end=\"5516\"\u003eThe exact clinical use and interpretation of CTG results should be performed by appropriately qualified healthcare professionals.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zjxypn\" dir=\"auto\" data-start=\"5523\" data-end=\"5549\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5551\" data-end=\"6440\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5551\" data-end=\"5587\"\u003e\n\u003ctr data-start=\"5551\" data-end=\"5587\"\u003e\n\u003cth data-start=\"5551\" data-end=\"5567\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"5567\" data-end=\"5587\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eMaestros CTG 150\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5598\" data-end=\"6440\"\u003e\n\u003ctr data-start=\"5598\" data-end=\"5659\"\u003e\n\u003ctd data-start=\"5598\" data-end=\"5617\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5600\" data-end=\"5616\"\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5617\" data-end=\"5659\" data-col-size=\"sm\"\u003eFetal \u0026amp; Maternal Monitor \/ CTG Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5660\" data-end=\"5697\"\u003e\n\u003ctd data-start=\"5660\" data-end=\"5674\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5662\" data-end=\"5673\"\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5674\" data-end=\"5697\" data-col-size=\"sm\"\u003e10.1-inch Color TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5698\" data-end=\"5757\"\u003e\n\u003ctd data-start=\"5698\" data-end=\"5717\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5700\" data-end=\"5716\"\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5717\" data-end=\"5757\" data-col-size=\"sm\"\u003eHigh-resolution tiltable touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5758\" data-end=\"5795\"\u003e\n\u003ctd data-start=\"5758\" data-end=\"5779\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5760\" data-end=\"5778\"\u003eFHR Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5779\" data-end=\"5795\" data-col-size=\"sm\"\u003eDual-channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5796\" data-end=\"5825\"\u003e\n\u003ctd data-start=\"5796\" data-end=\"5818\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5798\" data-end=\"5817\"\u003eTwin Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5818\" data-end=\"5825\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5826\" data-end=\"5886\"\u003e\n\u003ctd data-start=\"5826\" data-end=\"5847\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5828\" data-end=\"5846\"\u003eFHR Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5847\" data-end=\"5886\" data-col-size=\"sm\"\u003ePulsed Doppler with autocorrelation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5887\" data-end=\"5938\"\u003e\n\u003ctd data-start=\"5887\" data-end=\"5904\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5889\" data-end=\"5903\"\u003eFHR Traces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5904\" data-end=\"5938\" data-col-size=\"sm\"\u003eSeparate traces for each fetus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5939\" data-end=\"5970\"\u003e\n\u003ctd data-start=\"5939\" data-end=\"5962\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5941\" data-end=\"5961\"\u003eUterine Activity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5962\" data-end=\"5970\" data-col-size=\"sm\"\u003eTOCO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5971\" data-end=\"6009\"\u003e\n\u003ctd data-start=\"5971\" data-end=\"5993\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5973\" data-end=\"5992\"\u003eTOCO Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5993\" data-end=\"6009\" data-col-size=\"sm\"\u003eStrain gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6010\" data-end=\"6069\"\u003e\n\u003ctd data-start=\"6010\" data-end=\"6031\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6012\" data-end=\"6030\"\u003eFetal Movement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6031\" data-end=\"6069\" data-col-size=\"sm\"\u003eAutomatic fetal movement detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6070\" data-end=\"6130\"\u003e\n\u003ctd data-start=\"6070\" data-end=\"6089\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6072\" data-end=\"6088\"\u003eCTG Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6089\" data-end=\"6130\" data-col-size=\"sm\"\u003eAutomated CTG analysis scoring system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6131\" data-end=\"6179\"\u003e\n\u003ctd data-start=\"6131\" data-end=\"6145\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6133\" data-end=\"6144\"\u003ePrinter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6145\" data-end=\"6179\" data-col-size=\"sm\"\u003eBuilt-in thermal array printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6180\" data-end=\"6210\"\u003e\n\u003ctd data-start=\"6180\" data-end=\"6200\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6182\" data-end=\"6199\"\u003ePrinter Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6200\" data-end=\"6210\" data-col-size=\"sm\"\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6211\" data-end=\"6274\"\u003e\n\u003ctd data-start=\"6211\" data-end=\"6230\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6213\" data-end=\"6229\"\u003ePrinter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6230\" data-end=\"6274\" data-col-size=\"sm\"\u003eHigh-resolution, long-life thermal array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6275\" data-end=\"6307\"\u003e\n\u003ctd data-start=\"6275\" data-end=\"6295\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6277\" data-end=\"6294\"\u003eMaternal SpO₂\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6295\" data-end=\"6307\" data-col-size=\"sm\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6308\" data-end=\"6340\"\u003e\n\u003ctd data-start=\"6308\" data-end=\"6328\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6310\" data-end=\"6327\"\u003eMaternal NIBP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6328\" data-end=\"6340\" data-col-size=\"sm\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6341\" data-end=\"6386\"\u003e\n\u003ctd data-start=\"6341\" data-end=\"6368\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6343\" data-end=\"6367\"\u003ePatient Data Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"6368\" data-end=\"6386\"\u003eUp to 24 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6387\" data-end=\"6440\"\u003e\n\u003ctd data-start=\"6387\" data-end=\"6406\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6389\" data-end=\"6405\"\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6406\" data-end=\"6440\" data-col-size=\"sm\"\u003ePC\/server and wireless options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Maestros Electronics","offers":[{"title":"Default Title","offer_id":53408057000117,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Maestros-CTG-150-Fetal-Monitor.jpg?v=1790847853","url":"https:\/\/healthyantrastore.com\/products\/maestros-ctg-150-fetal-maternal-monitor","provider":"Health Yantra Store","version":"1.0","type":"link"}