{"product_id":"medicaid-bera-3000-beragraph-audiometry-system","title":"Medicaid BERA-3000 Beragraph – Brainstem Evoked Response Audiometry System","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eMedicaid BERA-3000 (Beragraph)\u003c\/strong\u003e is a diagnostic \u003cstrong\u003eBrainstem Evoked Response Audiometry (BERA)\u003c\/strong\u003e system designed by \u003cstrong\u003eMedicaid Systems\u003c\/strong\u003e for recording auditory evoked potentials and assessing objective hearing thresholds.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system combines high-performance amplifiers, 14-bit averaging, programmable auditory stimulation, automatic masking control, and advanced waveform analysis. In addition to BERA, the system supports \u003cstrong\u003eMLR, LLR, and P300\u003c\/strong\u003e testing, making it suitable for a range of auditory and evoked-potential assessment applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid BERA-3000 is designed to acquire and analyze small evoked-potential signals generated in response to auditory stimulation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIts averaging and waveform-analysis capabilities are intended to support objective assessment of auditory thresholds. The system can record multiple waveforms simultaneously and provides tools for comparing responses between the left and right ears, superimposing curves, smoothing stored data, and reformatting test parameters.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostic \u003cstrong\u003eBERA \/ Beragraph system\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-performance evoked-potential amplifiers\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e14-bit averaging\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eObjective auditory threshold assessment\u003c\/li\u003e\n\u003cli\u003eThreshold accuracy specified as greater than \u003cstrong\u003e5 dB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports differentiation of end-cochlear and retrocochlear deafness\u003c\/li\u003e\n\u003cli\u003eBurst, log-in, and click auditory stimulation modes\u003c\/li\u003e\n\u003cli\u003eCondensation, rarefaction and alternating stimulation\u003c\/li\u003e\n\u003cli\u003eStimulus intensity from \u003cstrong\u003e0–120 dB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic masking control\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e16 waveform recordings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAutomatic waveform marking\u003c\/li\u003e\n\u003cli\u003eLeft\/right ear split-screen comparison\u003c\/li\u003e\n\u003cli\u003eCurve superimposition\u003c\/li\u003e\n\u003cli\u003eSmoothing filters for stored data\u003c\/li\u003e\n\u003cli\u003eParameter reformatting during or after testing\u003c\/li\u003e\n\u003cli\u003eSupports BERA, MLR, LLR and P300 tests\u003c\/li\u003e\n\u003cli\u003eWindows-based operation software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eHigh-Performance Amplifiers\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BERA-3000 incorporates \u003cstrong\u003ehigh-performance amplifiers\u003c\/strong\u003e designed to acquire high-quality auditory evoked-potential signals.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAccurate signal acquisition is important in evoked-potential testing because the responses being measured can be relatively small compared with unwanted electrical and physiological signals.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e14-Bit Averaging \u0026amp; Threshold Assessment\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system uses \u003cstrong\u003e14-bit averaging\u003c\/strong\u003e for objective auditory threshold measurement.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe supplied specifications state threshold accuracy of \u003cstrong\u003egreater than 5 dB\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis averaging capability supports the identification and analysis of auditory evoked responses during testing.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAuditory Stimulation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BERA-3000 provides multiple auditory stimulation options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBurst\u003c\/li\u003e\n\u003cli\u003eLog-in\u003c\/li\u003e\n\u003cli\u003eClick\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe stimulation can be configured for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCondensation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRarefaction\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAlternating\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe specified stimulus intensity range is:\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003e0–120 dB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis provides flexibility for different auditory evoked-potential testing protocols.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eAutomatic Masking Control\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system includes \u003cstrong\u003eautomatic masking control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAccording to the supplied information, masking intensity is automatically controlled relative to the stimulating intensity while maintaining a constant programmed difference.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis helps simplify masking-related adjustments during applicable auditory testing procedures.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eSupported Evoked-Potential Tests\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BERA-3000 supports several testing modalities:\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eBERA\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eBrainstem Evoked Response Audiometry\u003c\/strong\u003e for recording auditory evoked responses and objective hearing assessment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eMLR\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eMiddle Latency Response\u003c\/strong\u003e testing for evaluation of middle-latency auditory responses.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eLLR\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eLong Latency Response\u003c\/strong\u003e testing for later auditory evoked responses.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eP300\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cstrong\u003eP300 cognitive evoked-potential testing\u003c\/strong\u003e for appropriate neurophysiological assessment protocols.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWaveform Recording\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system can record up to \u003cstrong\u003e16 waveforms\u003c\/strong\u003e and includes automatic waveform-marking capabilities.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis facilitates the organization and review of multiple responses acquired during an examination.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eLeft \u0026amp; Right Ear Comparison\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eA \u003cstrong\u003esplit-screen display\u003c\/strong\u003e allows responses from the left and right ears to be compared.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system also provides \u003cstrong\u003ecurve superimposition\u003c\/strong\u003e, allowing waveforms to be visually compared during analysis.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWaveform Processing \u0026amp; Analysis\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe software provides several analysis tools, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStored-data smoothing filters\u003c\/li\u003e\n\u003cli\u003eCurve superimposition\u003c\/li\u003e\n\u003cli\u003eSplit-screen ear comparison\u003c\/li\u003e\n\u003cli\u003eParameter reformatting\u003c\/li\u003e\n\u003cli\u003eWaveform auto-marking\u003c\/li\u003e\n\u003cli\u003eReview during and after testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThese functions provide flexibility when examining stored evoked-potential recordings.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eWindows-Based Software\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe BERA-3000 is designed for \u003cstrong\u003eWindows-based operation software\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe supplied compatibility information specifically identifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWindows 98\u003c\/li\u003e\n\u003cli\u003eWindows ME\u003c\/li\u003e\n\u003cli\u003eWindows XP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe software is described as user-friendly and provides the interface for acquisition, analysis, review and reporting of evoked-potential tests.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eClinical Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid BERA-3000 may be used in appropriate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAudiology departments\u003c\/li\u003e\n\u003cli\u003eENT clinics\u003c\/li\u003e\n\u003cli\u003eHospitals\u003c\/li\u003e\n\u003cli\u003eHearing assessment centers\u003c\/li\u003e\n\u003cli\u003eNeurodiagnostic laboratories\u003c\/li\u003e\n\u003cli\u003eAudiology teaching institutions\u003c\/li\u003e\n\u003cli\u003eResearch laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe system is designed for auditory evoked-potential testing and related evoked-response examinations.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedicaid Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBERA-3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBeragraph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrainstem Evoked Response Audiometry System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-performance evoked-potential amplifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAveraging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreshold Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;5 dB, as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStimulus Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBurst, Log-in, Click\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolarity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCondensation, Rarefaction, Alternating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStimulus Intensity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–120 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMasking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic masking intensity control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Recording\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 16 waveforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEar Comparison\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft\/right split-screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurve Analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuperimposition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Processing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmoothing filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReformatting during\/after testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBERA, MLR, LLR, P300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows-based operation software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecified Windows Platforms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows 98 \/ ME \/ XP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp dir=\"auto\"\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53342735499445,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medicaid-BERA-3000-Brainstem-Evoked-Response-Audiometry.jpg?v=1789795251","url":"https:\/\/healthyantrastore.com\/products\/medicaid-bera-3000-beragraph-audiometry-system","provider":"Health Yantra Store","version":"1.0","type":"link"}