{"product_id":"medicaid-neurostim-ns-2-emg-ncv-ep-machine","title":"Medicaid NeuroStim NS-2 EMG NCV EP Machine","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eMedicaid NeuroStim NS-2\u003c\/strong\u003e is a \u003cstrong\u003e2-channel computerized EMG\/NCV\/EP system\u003c\/strong\u003e, upgradeable to 4 channels, designed for neurological and neurophysiological investigations in hospitals, neurology clinics, diagnostic centers, medical colleges, and research facilities.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eUSB-based NeuroStim NS-2\u003c\/strong\u003e connects directly to a Windows computer and draws operating power through the USB connection, eliminating the need for a separate external power supply. The system is designed to simplify electrodiagnostic testing with automatic parameter settings, \u003cstrong\u003eautomatic NCV calculations\u003c\/strong\u003e, real-time waveform acquisition, waveform storage and replay, automatic amplitude and latency marking, and comprehensive report generation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system supports a broad range of examinations, including \u003cstrong\u003eEMG, Motor and Sensory NCV\/NCS, F-Wave, H-Reflex, VEP, BAEP\/BERA, SSEP, SSR and other compatible evoked potential studies\u003c\/strong\u003e, depending on the installed configuration and accessories.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-Channel EMG\/NCV\/EP System\u003c\/strong\u003e – Two-channel configuration with upgradeability to four channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB-Based Operation\u003c\/strong\u003e – Connects directly to a computer through USB.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo External Power Supply Required\u003c\/strong\u003e – The system receives operating power through the USB connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComputerized Windows-Based System\u003c\/strong\u003e – Designed for operation with a compatible Windows PC or laptop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMG Testing\u003c\/strong\u003e – Supports surface and needle EMG examinations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor \u0026amp; Sensory NCV\/NCS\u003c\/strong\u003e – Supports nerve conduction studies for motor and sensory nerves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic NCV Calculation\u003c\/strong\u003e – Automatically calculates relevant nerve conduction parameters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eF-Wave \u0026amp; H-Reflex\u003c\/strong\u003e – Supports commonly used late-response studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvoked Potential Testing\u003c\/strong\u003e – Supports compatible VEP, BAEP\/BERA and somatosensory evoked potential studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive \u0026amp; Averaged Waveforms\u003c\/strong\u003e – Displays live signals alongside averaged waveforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Amplitude \u0026amp; Latency Marking\u003c\/strong\u003e – Helps simplify waveform analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous EMG Recording\u003c\/strong\u003e – Up to \u003cstrong\u003e13 minutes of continuous EMG waveform\u003c\/strong\u003e can be stored and replayed with audio, as specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Nerve Display\u003c\/strong\u003e – More than one nerve can be listed on a single screen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Parameters\u003c\/strong\u003e – Test parameters are automatically configured according to the selected testing mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Auto Reporting\u003c\/strong\u003e – Generates reports containing test values in tabular format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMS Word Report Printing\u003c\/strong\u003e – Supports report printing in MS Word format.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Muscle \u0026amp; Nerve Guide\u003c\/strong\u003e – Picture-based reference guide for muscles and nerves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgradeable Configuration\u003c\/strong\u003e – 2-channel system can be upgraded to 4 channels, subject to configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Certified\u003c\/strong\u003e – Supplied as a CE-certified medical diagnostic system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eEMG Testing\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe NeuroStim NS-2 is designed for \u003cstrong\u003eelectromyography\u003c\/strong\u003e, allowing electrical activity associated with muscles to be recorded and analyzed. It supports applicable \u003cstrong\u003esurface and needle EMG\u003c\/strong\u003e examinations and provides waveform acquisition, storage, replay, and analysis features.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system can display EMG signals in real time and provides automatic marking functions for relevant waveform parameters.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eNCV \/ NCS Testing\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eThe system supports \u003cstrong\u003eMotor and Sensory Nerve Conduction Studies\u003c\/strong\u003e. During compatible NCV examinations, the system records nerve responses and calculates relevant parameters such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLatency\u003c\/li\u003e\n\u003cli\u003eAmplitude\u003c\/li\u003e\n\u003cli\u003eConduction velocity\u003c\/li\u003e\n\u003cli\u003eRelevant nerve conduction values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eautomatic NCV calculation\u003c\/strong\u003e feature helps streamline the testing and reporting workflow.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eEvoked Potential Testing\u003c\/h2\u003e\n\u003cp dir=\"auto\"\u003eDepending on the installed configuration and accessories, the NeuroStim NS-2 supports compatible evoked potential examinations such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVEP – Visual Evoked Potential\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBAEP \/ BERA – Brainstem Auditory Evoked Potential\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSSEP – Somatosensory Evoked Potential\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOther compatible EP studies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedicaid Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNeuroStim NS-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComputerized EMG \/ NCV \/ EP System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpgradeability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradable to \u003cstrong\u003e4 Channels\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows-Based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeedle EMG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface EMG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNCV \/ NCS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor \u0026amp; Sensory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF-Wave\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eH-Reflex\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVEP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBAEP \/ BERA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSSEP \/ Somatosensory EP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSSR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLive \u0026amp; Averaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMG Waveform Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 13 minutes continuous recording*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Replay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Amplitude Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Latency Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic NCV Calculation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Nerve Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMore than one nerve on a single screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto Report Generation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReport Format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS Word\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReport Values\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTabular format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMuscle\/Nerve Guide\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in picture guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE Certified*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeurology, Hospitals, Clinics, Diagnostic Centers \u0026amp; Research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53285871157429,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medicaid-NeuroStim-NS-2-EMG-NCV-EP-Machine_2-Channel-USB-Based.jpg?v=1789564353","url":"https:\/\/healthyantrastore.com\/products\/medicaid-neurostim-ns-2-emg-ncv-ep-machine","provider":"Health Yantra Store","version":"1.0","type":"link"}