{"product_id":"medicaid-neurostim-ultra-ns-2-emg-ncv-ep-machine","title":"Medicaid NeuroStim Ultra NS-2 EMG NCV EP Machine","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eMedicaid NeuroStim Ultra NS-2\u003c\/strong\u003e is an ultra-portable neurological diagnostic system designed for \u003cstrong\u003eElectromyography (EMG), Nerve Conduction Velocity (NCV\/NCS), and Evoked Potential (EP)\u003c\/strong\u003e studies. Its compact design and laptop connectivity make it suitable for \u003cstrong\u003ehospitals, neurology departments, diagnostic centers, ICUs, bedside examinations, and clinical research\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe system supports commonly used neurological investigations including \u003cstrong\u003eNeedle EMG, NCV\/NCS, F-Wave, H-Reflex, and Evoked Potential studies\u003c\/strong\u003e. It provides live and averaged waveform visualization, automatic amplitude and latency marking, waveform storage and replay, and structured reporting to support an efficient neurodiagnostic workflow.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003e4-channel configuration\u003c\/strong\u003e allows simultaneous acquisition and analysis of multiple signals, while the built-in muscle and nerve picture guide provides useful anatomical reference during testing.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-Portable Design\u003c\/strong\u003e – Compact system suitable for bedside and mobile neurodiagnostic applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMG, NCV \u0026amp; EP Testing\u003c\/strong\u003e – Integrated platform for major electrodiagnostic and evoked potential studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-Channel Configuration\u003c\/strong\u003e – Supports multi-channel signal acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLaptop Connectivity\u003c\/strong\u003e – Designed for convenient operation and waveform analysis through a connected computer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUSB Interface\u003c\/strong\u003e – Facilitates system connectivity and data transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLive \u0026amp; Averaged Waveforms\u003c\/strong\u003e – View acquired signals and averaged responses during examination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Amplitude \u0026amp; Latency Marking\u003c\/strong\u003e – Helps streamline waveform analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMG Waveform Storage \u0026amp; Replay\u003c\/strong\u003e – Allows recorded EMG signals to be stored and reviewed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAudio Replay\u003c\/strong\u003e – Supports audio replay of recorded EMG activity where applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Nerve Display\u003c\/strong\u003e – Enables convenient viewing of nerve test information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Muscle \u0026amp; Nerve Guide\u003c\/strong\u003e – Picture-based anatomical reference for muscles and nerves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMUP Selection\u003c\/strong\u003e – Supports manual and automatic motor unit potential selection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Reporting\u003c\/strong\u003e – Test results can be organized into structured reports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Neurodiagnostic Tests\u003c\/strong\u003e – Supports F-Wave, NCV\/NCS, Needle EMG, H-Reflex and Evoked Potential studies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eICU \u0026amp; Bedside Suitable\u003c\/strong\u003e – Portable format supports neurological assessment in critical-care and bedside environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResearch Application\u003c\/strong\u003e – Can be used for compatible clinical and neurophysiological research applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eStandard Tests\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eMedicaid NeuroStim Ultra NS-2\u003c\/strong\u003e supports a range of electrodiagnostic investigations, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eNeedle EMG\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNCV \/ NCS – Nerve Conduction Studies\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eF-Wave\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eH-Reflex\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEvoked Potentials\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOther compatible electrodiagnostic studies depending on system configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedicaid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNeuroStim Ultra NS-2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltra Portable EMG \/ NCV \/ EP Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog \/ Digital Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-Wave, NCV, Needle EMG, H-Reflex, Evoked Potentials, NCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeedle EMG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNCV\/NCS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNerve Conduction Velocity \/ Nerve Conduction Studies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvoked Potentials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMUP Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLive \u0026amp; Averaged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWaveform Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAudio Replay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplitude Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLatency Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMuscle\/Nerve Guide\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in picture guide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLaptop \/ USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2%*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStated Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e99%*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1%*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 kg*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHospital, Clinical, ICU, Bedside Recording \u0026amp; Research\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"auto\"\u003e\u003c\/h3\u003e\n\u003ch3 dir=\"auto\"\u003ePackage Contents\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003ePackage contents may vary depending on the configuration supplied. The system may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNeuroStim Ultra Series EMG\/NCV\/EP unit\u003c\/li\u003e\n\u003cli\u003eLaptop connectivity accessories\u003c\/li\u003e\n\u003cli\u003eAdjustable head pin\u003c\/li\u003e\n\u003cli\u003eLED visual stimulus goggles\u003c\/li\u003e\n\u003cli\u003eRequired connecting cables\/accessories\u003c\/li\u003e\n\u003cli\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eDocumentation\/manuals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53282326020277,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/NeuroStim-Ultra-Wireless-EMG-NCV-EP-Machine.jpg?v=1789556909","url":"https:\/\/healthyantrastore.com\/products\/medicaid-neurostim-ultra-ns-2-emg-ncv-ep-machine","provider":"Health Yantra Store","version":"1.0","type":"link"}