{"product_id":"medicaid-psg-2018-sleep-study-system-digital-video-polysomnography-psg-machine","title":"Medicaid Ultra Brief Pulse ECT UBE Series – Ultra-Brief Pulse ECT Machine","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eMedicaid Ultra Brief Pulse ECT UBE Series\u003c\/strong\u003e is an Electroconvulsive Therapy (ECT) system designed specifically for \u003cstrong\u003eUltra-Brief Pulse stimulation\u003c\/strong\u003e. The supplied product information specifies an \u003cstrong\u003eultra-brief pulse width of 0.3 ms at 800 mA current\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe UBE Series is designed around refined ECT stimulation parameters and is intended for professional clinical environments where Ultra-Brief Pulse ECT is used under appropriate medical supervision.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Description\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eUltra-Brief Pulse ECT uses a substantially shorter electrical pulse width than conventional ECT approaches. The Medicaid UBE Series is configured with a \u003cstrong\u003e0.3 ms pulse width and 800 mA current\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe supplied material describes research findings reporting differences in seizure induction requirements, seizure manifestation, and cognitive effects when Ultra-Brief Pulse stimulation is compared with standard ECT. These findings should be understood as \u003cstrong\u003ereported study observations rather than guaranteed outcomes for every patient\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDedicated \u003cstrong\u003eUltra-Brief Pulse ECT\u003c\/strong\u003e system\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e0.3 ms ultra-brief pulse width\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e800 mA current\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDesigned for Ultra-Brief Pulse ECT protocols\u003c\/li\u003e\n\u003cli\u003eRefined stimulation parameters\u003c\/li\u003e\n\u003cli\u003eDesigned for professional ECT clinical environments\u003c\/li\u003e\n\u003cli\u003eIntended to support controlled electrical stimulation during ECT\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eUltra-Brief Pulse Stimulation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid UBE Series provides an ultra-brief pulse width of \u003cstrong\u003e0.3 milliseconds (ms)\u003c\/strong\u003e at \u003cstrong\u003e800 mA\u003c\/strong\u003e current.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe supplied product information states that optimized ultra-brief stimulation parameters have been investigated as an alternative approach to conventional ECT stimulation.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eReported Seizure Threshold Differences\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eAccording to the supplied material, studies have reported that Ultra-Brief Pulse stimulation can be more efficient for seizure induction, with the \u003cstrong\u003echarge at seizure threshold reported as at least three times lower\u003c\/strong\u003e than with the stimulation parameters discussed in those comparisons.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is a study-derived claim and should not be interpreted as a guaranteed reduction for every patient or treatment protocol.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eCognitive Effects\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe supplied information describes a \u003cstrong\u003esubstantial difference in cognitive effects\u003c\/strong\u003e associated with Ultra-Brief Pulse ECT.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIt also reports that some patients in the referenced studies reported \u003cstrong\u003eno noticeable memory loss\u003c\/strong\u003e after multiple Ultra-Brief Pulse ECT treatments.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIndividual cognitive and memory effects can vary considerably, and clinical outcomes depend on treatment parameters, patient characteristics, treatment frequency, and other factors.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eSeizure Manifestation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe supplied product information states that \u003cstrong\u003eseizure manifestations are distinct with Ultra-Brief Pulse stimulation\u003c\/strong\u003e compared with standard ECT.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis characteristic may be relevant when clinicians assess and monitor seizure activity during treatment.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eUltra-Brief ECT vs Standard ECT\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe supplied material cites studies describing the difference between Ultra-Brief ECT and standard ECT as being comparable to \u003cstrong\u003e“day and night.”\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eFor an objective product page, this should be treated as a \u003cstrong\u003ereported study characterization\u003c\/strong\u003e, rather than an independent assessment or guaranteed clinical result.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eClinical Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid UBE Series is intended for professional environments providing ECT, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePsychiatry departments\u003c\/li\u003e\n\u003cli\u003ePsychiatric hospitals\u003c\/li\u003e\n\u003cli\u003eMental health facilities\u003c\/li\u003e\n\u003cli\u003eHospitals with ECT services\u003c\/li\u003e\n\u003cli\u003eSpecialized ECT treatment centers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eECT should be administered only by appropriately trained medical professionals using established clinical protocols and suitable patient monitoring.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedicaid Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUBE Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltra-Brief Pulse ECT Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTherapy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElectroconvulsive Therapy (ECT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.3 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e800 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStimulation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUltra-Brief Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProfessional ECT treatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClinical Area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePsychiatry \/ Mental Health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53310029791413,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medicaid-UBE-Series-Ultra-Brief-Pulse-ECT-Machine.jpg?v=1789642500","url":"https:\/\/healthyantrastore.com\/products\/medicaid-psg-2018-sleep-study-system-digital-video-polysomnography-psg-machine","provider":"Health Yantra Store","version":"1.0","type":"link"}