{"product_id":"medicaid-transcranial-direct-current-stimulator-tdcs-machine","title":"Medicaid Transcranial Direct Current Stimulator – tDCS Machine","description":"\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eMedicaid Transcranial Direct Current Stimulator (tDCS)\u003c\/strong\u003e is a non-invasive neuromodulation device designed to deliver a \u003cstrong\u003eweak direct electrical current to the scalp\u003c\/strong\u003e to modulate neuronal activity in targeted brain regions. The system uses an anode and cathode electrode arrangement, with adjustable stimulation parameters for controlled treatment sessions.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe portable, battery-powered design incorporates a digital display, adjustable treatment timer, impedance monitoring, and stable current output for controlled stimulation.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eTranscranial Direct Current Stimulation (tDCS) applies a low-level direct electrical current between two electrodes positioned on the head. The supplied product information describes current levels typically in the \u003cstrong\u003e1–2 mA range\u003c\/strong\u003e, with the polarity of stimulation influencing neuronal excitability in the targeted region.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid tDCS system provides adjustable session timing and stimulation parameters in a handheld format, making it suitable for appropriately supervised neuromodulation and rehabilitation applications.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-invasive transcranial direct current stimulation\u003c\/li\u003e\n\u003cli\u003eLow-level direct current stimulation\u003c\/li\u003e\n\u003cli\u003eTypical current range of \u003cstrong\u003e1–2 mA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnode (+) and cathode (−) electrode configuration\u003c\/li\u003e\n\u003cli\u003eDigital display\u003c\/li\u003e\n\u003cli\u003eAdjustable treatment timer from \u003cstrong\u003e0–30 minutes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow-frequency pulse setting of \u003cstrong\u003e1–150 Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eImpedance monitoring for treatment safety\u003c\/li\u003e\n\u003cli\u003eStable current output\u003c\/li\u003e\n\u003cli\u003ePortable handheld design\u003c\/li\u003e\n\u003cli\u003eBattery-powered operation\u003c\/li\u003e\n\u003cli\u003eSuitable for controlled neuromodulation protocols\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eHow tDCS Works\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe device delivers a low-level electrical current between an \u003cstrong\u003eanode (positive electrode)\u003c\/strong\u003e and a \u003cstrong\u003ecathode (negative electrode)\u003c\/strong\u003e placed on the scalp.\\\u003c\/p\u003e\n\u003cp dir=\"auto\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe supplied description states that the polarity of the stimulation can \u003cstrong\u003eincrease or decrease neuronal excitability\u003c\/strong\u003e in targeted brain regions. The precise physiological response depends on factors such as electrode placement, current intensity, stimulation duration, and individual patient characteristics.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eCurrent \u0026amp; Stimulation Control\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe system is designed to provide controlled low-level electrical stimulation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eAccording to the supplied information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTypical current:\u003c\/strong\u003e 1–2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrodes:\u003c\/strong\u003e Anode and cathode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 1–150 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTimer:\u003c\/strong\u003e 0–30 minutes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent output:\u003c\/strong\u003e Stable\/controlled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eTreatment parameters should be selected according to the manufacturer's instructions and the applicable clinical protocol.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eDigital Display \u0026amp; Timer\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe device includes a \u003cstrong\u003edigital display\u003c\/strong\u003e for monitoring treatment parameters and an adjustable timer ranging from \u003cstrong\u003e0 to 30 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe timer allows the operator to set the intended stimulation duration for a treatment session.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eImpedance Monitoring\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe tDCS system incorporates \u003cstrong\u003eimpedance monitoring\u003c\/strong\u003e, which can help identify inappropriate electrode contact or changes in the electrical interface before or during stimulation.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis is an important feature for controlled transcranial electrical stimulation because electrode contact and impedance can affect current delivery.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003ePortable Battery-Powered Design\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medicaid tDCS machine is designed as a \u003cstrong\u003eportable handheld, battery-powered unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis design can facilitate use in appropriate rehabilitation and clinical environments without requiring continuous mains power.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eClinical \u0026amp; Therapeutic Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe supplied information identifies several areas in which tDCS has been studied or used as an adjunctive intervention.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eStroke Rehabilitation\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003etDCS may be used alongside \u003cstrong\u003ephysical or occupational therapy\u003c\/strong\u003e as part of selected stroke rehabilitation protocols, including rehabilitation targeting motor or speech function.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eMental Health\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003etDCS has been studied in relation to conditions including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMajor depressive disorder\u003c\/li\u003e\n\u003cli\u003eAnxiety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eIts use should be based on the relevant clinical indication and professional guidance.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eChronic Pain\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003etDCS has also been studied as a neuromodulation approach for \u003cstrong\u003echronic pain\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eClinical response can vary, and tDCS should not be presented as a guaranteed treatment for any condition.\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedicaid Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTranscranial Direct Current Stimulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStimulation Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-invasive direct electrical stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnode (+) and Cathode (−)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–150 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment Timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImpedance monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStable current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePortable handheld\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medicaid","offers":[{"title":"Default Title","offer_id":53338143129781,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medicaid-tDCS-Machine-Transcranial-Direct-Current-Stimulator.jpg?v=1789731285","url":"https:\/\/healthyantrastore.com\/products\/medicaid-transcranial-direct-current-stimulator-tdcs-machine","provider":"Health Yantra Store","version":"1.0","type":"link"}