{"product_id":"medinain-flare-5m-ot-light-advanced-surgical-operating-theatre-light","title":"Medinain Flare-5(M) OT Light – Advanced Surgical Operating Theatre Light","description":"\u003cp dir=\"auto\"\u003eThe \u003cstrong\u003eMedinain \u003c\/strong\u003e\u003cstrong\u003eFlare-5(M)\u003c\/strong\u003e is an advanced \u003cstrong\u003eOT \/ surgical operating theatre light\u003c\/strong\u003e designed to provide high-intensity illumination during surgical procedures. It combines a \u003cstrong\u003ehigh-definition optical system\u003c\/strong\u003e with a quick-response \u003cstrong\u003edigital touch control panel\u003c\/strong\u003e, allowing convenient intensity adjustment and lamp control.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIts streamlined design is intended to minimize disruption to \u003cstrong\u003elaminar airflow\u003c\/strong\u003e in the operating theatre, while its lightweight construction supports easy positioning and stable placement during procedures.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Flare-5(M) incorporates \u003cstrong\u003e65 LEDs\u003c\/strong\u003e and provides illumination intensity of up to \u003cstrong\u003e175,000 Lux\u003c\/strong\u003e. Its optical system offers a specified spot diameter of \u003cstrong\u003e100–150 mm\u003c\/strong\u003e, with a color temperature range of \u003cstrong\u003e3800–4800 K\u003c\/strong\u003e and a \u003cstrong\u003eCRI of 93 Ra\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe light features \u003cstrong\u003edigital touch intensity control from 10–100%\u003c\/strong\u003e and a \u003cstrong\u003edual memory function\u003c\/strong\u003e for convenient operation.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-intensity surgical illumination up to \u003cstrong\u003e175,000 Lux\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-definition optical system\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e65 LEDs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDigital touch control panel\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e10–100% digital intensity control\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eManual focusing\u003c\/li\u003e\n\u003cli\u003eColor temperature of \u003cstrong\u003e3800–4800 K\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh \u003cstrong\u003eCRI of 93 Ra\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLED average life of \u003cstrong\u003emore than 50,000 hours\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eStreamlined design for reduced laminar airflow disruption\u003c\/li\u003e\n\u003cli\u003eLightweight construction for easy positioning\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDual memory function\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e220V\/50Hz AC power supply\u003c\/li\u003e\n\u003cli\u003e52W power consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"auto\"\u003eHigh-Intensity Surgical Illumination\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medinain Flare-5(M) provides a maximum illumination intensity of \u003cstrong\u003e175,000 Lux\u003c\/strong\u003e, supporting bright surgical-field illumination.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThe specified light spot diameter is \u003cstrong\u003e100–150 mm\u003c\/strong\u003e, while the depth diameter is specified as \u003cstrong\u003e10–25 cm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eDigital Touch Intensity Control\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe integrated digital touch panel allows the operator to adjust light intensity across a \u003cstrong\u003e10–100% range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eThis provides convenient control of illumination according to the requirements of the operating environment.\u003c\/p\u003e\n\u003ch3\u003eDual Memory Function\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Flare-5(M) also incorporates a \u003cstrong\u003edual memory function\u003c\/strong\u003e, allowing two lighting settings to be retained for convenient access.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eHigh-Definition Optical System\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Flare-5(M) uses a high-definition optical system with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e65 LEDs\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eColor temperature: \u003cstrong\u003e3800–4800 K\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eColor Rendering Index: \u003cstrong\u003e93 Ra\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eManual focusing\u003c\/li\u003e\n\u003cli\u003eLED average life: \u003cstrong\u003e\u0026gt;50,000 hours\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe CRI of 93 Ra is specified to support accurate rendering of illuminated colors in the surgical field.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eStreamlined OT Light Design\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Flare series uses a streamlined lamp design intended to \u003cstrong\u003eminimize disruption of laminar airflow\u003c\/strong\u003e within the operating theatre.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003eIts lightweight construction is designed to make lamp positioning easier while maintaining stable positioning once adjusted.\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMedinain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFlare-5(M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eOT Light \/ Surgical Operating Theatre Light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIllumination Intensity\u003c\/td\u003e\n\u003ctd\u003e175,000 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpot Diameter\u003c\/td\u003e\n\u003ctd\u003e100–150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth Diameter\u003c\/td\u003e\n\u003ctd\u003e10–25 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Temperature\u003c\/td\u003e\n\u003ctd\u003e3800–4800 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor Rendering Index\u003c\/td\u003e\n\u003ctd\u003e93 Ra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocusing\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Average Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of LEDs\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Diameter\u003c\/td\u003e\n\u003ctd\u003e711 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntensity Control\u003c\/td\u003e\n\u003ctd\u003e10–100% Digital Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220V \/ 50Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e52 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Function\u003c\/td\u003e\n\u003ctd\u003eDual Memory Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"auto\"\u003eClinical \/ OT Applications\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003eThe Medinain Flare-5(M) is designed for use as an \u003cstrong\u003eoperating theatre surgical light\u003c\/strong\u003e, where high-intensity illumination of the surgical field is required.\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003ePotential applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOperating theatres\u003c\/li\u003e\n\u003cli\u003eSurgical rooms\u003c\/li\u003e\n\u003cli\u003eProcedure rooms\u003c\/li\u003e\n\u003cli\u003eHospital operating departments\u003c\/li\u003e\n\u003cli\u003eClinical surgical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\"\u003eThe specific suitability of the light should be assessed according to the operating theatre's installation requirements and applicable electrical and medical-device standards.\u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Medinain","offers":[{"title":"Default Title","offer_id":53342966251701,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medinain-Flare-5_M_-OT-Light-Surgical-Operating-Light.jpg?v=1789809341","url":"https:\/\/healthyantrastore.com\/products\/medinain-flare-5m-ot-light-advanced-surgical-operating-theatre-light","provider":"Health Yantra Store","version":"1.0","type":"link"}