{"product_id":"medinain-suction-apparatus-25d","title":"Medinain Suction Apparatus 25D","description":"\u003cp dir=\"auto\" data-start=\"34\" data-end=\"344\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"38\" data-end=\"72\"\u003eMedinain Suction Apparatus 25D\u003c\/strong\u003e is an electrically operated medical suction apparatus equipped with an \u003cstrong data-start=\"144\" data-end=\"168\"\u003eoil-free piston pump\u003c\/strong\u003e and a dual-glass-jar configuration. It is specified with a pumping rate of \u003cstrong data-start=\"244\" data-end=\"257\"\u003e≥20 L\/min\u003c\/strong\u003e, maximum vacuum of \u003cstrong data-start=\"277\" data-end=\"287\"\u003e90 kPa\u003c\/strong\u003e, and a maximum negative pressure value of \u003cstrong data-start=\"330\" data-end=\"343\"\u003e\u0026gt;0.09 MPa\u003c\/strong\u003e.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"346\" data-end=\"625\"\u003eThe 25D features both \u003cstrong data-start=\"368\" data-end=\"409\"\u003ehand-switch and foot-switch operation\u003c\/strong\u003e, adjustable negative pressure, and an overflow protection mechanism. Its oil-free pump design is intended to provide clean operation without oil and smoke contamination and without the need for routine oil addition.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"627\" data-end=\"644\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"646\" data-end=\"1337\"\u003e\n\u003cli data-section-id=\"141q9jw\" data-start=\"646\" data-end=\"672\"\u003e\u003cstrong data-start=\"648\" data-end=\"672\"\u003eOil-free piston pump\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ggnp24\" data-start=\"673\" data-end=\"722\"\u003eClean operation without oil and smoke pollution\u003c\/li\u003e\n\u003cli data-section-id=\"1lwj9j3\" data-start=\"723\" data-end=\"779\"\u003eNo routine oil addition required for daily maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"1hpcxoj\" data-start=\"780\" data-end=\"806\"\u003eAutomatic operation mode\u003c\/li\u003e\n\u003cli data-section-id=\"awvr5z\" data-start=\"807\" data-end=\"846\"\u003eHand-switch and foot-switch operation\u003c\/li\u003e\n\u003cli data-section-id=\"12kt5o9\" data-start=\"847\" data-end=\"877\"\u003eAdjustable negative pressure\u003c\/li\u003e\n\u003cli data-section-id=\"1lylh2g\" data-start=\"878\" data-end=\"921\"\u003eNo-level pressure adjustment as specified\u003c\/li\u003e\n\u003cli data-section-id=\"1kbx4rw\" data-start=\"922\" data-end=\"953\"\u003eOverflow protection mechanism\u003c\/li\u003e\n\u003cli data-section-id=\"1lv2oe8\" data-start=\"954\" data-end=\"1009\"\u003eReverse-flow prevention design when the machine stops\u003c\/li\u003e\n\u003cli data-section-id=\"1kxrb2k\" data-start=\"1010\" data-end=\"1039\"\u003e\u003cstrong data-start=\"1012\" data-end=\"1039\"\u003e2 glass collection jars\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1o4t0vw\" data-start=\"1040\" data-end=\"1068\"\u003e\u003cstrong data-start=\"1042\" data-end=\"1068\"\u003e≥20 L\/min pumping rate\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"j7h6fe\" data-start=\"1069\" data-end=\"1096\"\u003e\u003cstrong data-start=\"1071\" data-end=\"1096\"\u003e90 kPa maximum vacuum\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1ufwc5e\" data-start=\"1097\" data-end=\"1145\"\u003eMaximum negative pressure value: \u003cstrong data-start=\"1132\" data-end=\"1145\"\u003e\u0026gt;0.09 MPa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1hvaq4l\" data-start=\"1146\" data-end=\"1169\"\u003eSilicone suction pipe\u003c\/li\u003e\n\u003cli data-section-id=\"1qp2o6y\" data-start=\"1170\" data-end=\"1207\"\u003eComplete plastic panel construction\u003c\/li\u003e\n\u003cli data-section-id=\"1mpncf2\" data-start=\"1208\" data-end=\"1228\"\u003eElectric operation\u003c\/li\u003e\n\u003cli data-section-id=\"1jl51bv\" data-start=\"1229\" data-end=\"1257\"\u003eNoise level: \u003cstrong data-start=\"1244\" data-end=\"1257\"\u003e≤65 dB(A)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"d7tkde\" data-start=\"1258\" data-end=\"1290\"\u003ePower consumption: \u003cstrong data-start=\"1279\" data-end=\"1290\"\u003e≤180 VA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19mgw4b\" data-start=\"1291\" data-end=\"1310\"\u003eWeight: \u003cstrong data-start=\"1301\" data-end=\"1310\"\u003e14 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1q2p8ts\" data-start=\"1311\" data-end=\"1337\"\u003eContinuity rate: \u003cstrong data-start=\"1330\" data-end=\"1337\"\u003e50%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ymkdbl\" dir=\"auto\" data-start=\"1339\" data-end=\"1362\"\u003eOil-Free Piston Pump\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1364\" data-end=\"1414\"\u003eThe Medinain 25D uses an \u003cstrong data-start=\"1389\" data-end=\"1413\"\u003eoil-free piston pump\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1416\" data-end=\"1477\"\u003eAccording to the supplied product description, this provides:\u003c\/p\u003e\n\u003cul data-start=\"1479\" data-end=\"1602\"\u003e\n\u003cli data-section-id=\"ggnp24\" data-start=\"1479\" data-end=\"1528\"\u003eClean operation without oil and smoke pollution\u003c\/li\u003e\n\u003cli data-section-id=\"lsiarw\" data-start=\"1529\" data-end=\"1571\"\u003eNo need to add oil for daily maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"mvgvsa\" data-start=\"1572\" data-end=\"1602\"\u003eConvenient routine operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1604\" data-end=\"1710\"\u003eThe oil-free design is intended to simplify maintenance while providing the specified suction performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"115w4dw\" dir=\"auto\" data-start=\"1712\" data-end=\"1743\"\u003eAdjustable Negative Pressure\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1745\" data-end=\"1893\"\u003eThe Medinain 25D allows the user to \u003cstrong data-start=\"1781\" data-end=\"1821\"\u003eselect negative pressure as required\u003c\/strong\u003e, with the supplied description specifying no-level pressure adjustment.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1895\" data-end=\"2005\"\u003eIt also incorporates an \u003cstrong data-start=\"1919\" data-end=\"1952\"\u003eoverflow protection mechanism\u003c\/strong\u003e, described as providing safe and reliable operation.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2007\" data-end=\"2120\"\u003eThe specified maximum negative pressure value is \u003cstrong data-start=\"2056\" data-end=\"2069\"\u003e\u0026gt;0.09 MPa\u003c\/strong\u003e, while the maximum vacuum is listed as \u003cstrong data-start=\"2109\" data-end=\"2119\"\u003e90 kPa\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"18clqfp\" dir=\"auto\" data-start=\"2122\" data-end=\"2153\"\u003eHand \u0026amp; Foot Switch Operation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2155\" data-end=\"2177\"\u003eThe 25D features both:\u003c\/p\u003e\n\u003cul data-start=\"2179\" data-end=\"2214\"\u003e\n\u003cli data-section-id=\"3naf21\" data-start=\"2179\" data-end=\"2196\"\u003e\u003cstrong data-start=\"2181\" data-end=\"2196\"\u003eHand switch\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"cizprc\" data-start=\"2197\" data-end=\"2214\"\u003e\u003cstrong data-start=\"2199\" data-end=\"2214\"\u003eFoot switch\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2216\" data-end=\"2305\"\u003eThis provides alternative operating methods depending on the clinical workflow and setup.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1d65hl1\" dir=\"auto\" data-start=\"2307\" data-end=\"2330\"\u003eDual Collection Jars\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2332\" data-end=\"2395\"\u003eThe apparatus is equipped with \u003cstrong data-start=\"2363\" data-end=\"2379\"\u003e2 glass jars\u003c\/strong\u003e for collection.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2397\" data-end=\"2595\"\u003eThe supplied specification identifies the number of glass jars but does not provide an individual or combined jar capacity, so that information should be confirmed from the manufacturer if required.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b3eyhl\" dir=\"auto\" data-start=\"2597\" data-end=\"2623\"\u003eReverse-Flow Protection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2625\" data-end=\"2807\"\u003eThe product description states that there is \u003cstrong data-start=\"2670\" data-end=\"2723\"\u003eno flow-backwards pressure when the machine stops\u003c\/strong\u003e, helping prevent collected liquid from flowing backward through the suction system.\u003c\/p\u003e\n\u003ch3 data-section-id=\"emtjju\" dir=\"auto\" data-start=\"2809\" data-end=\"2831\"\u003eOverflow Protection\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2833\" data-end=\"2913\"\u003eAn \u003cstrong data-start=\"2836\" data-end=\"2869\"\u003eoverflow protection mechanism\u003c\/strong\u003e is included in the specified configuration.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2915\" data-end=\"3073\"\u003eThis feature is intended to provide additional protection against fluid entering the pump system when the collection arrangement reaches its applicable limit.\u003c\/p\u003e\n\u003ch3 data-section-id=\"f7mrsu\" dir=\"auto\" data-start=\"3075\" data-end=\"3104\"\u003ePlastic Panel Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3106\" data-end=\"3207\"\u003eThe Medinain 25D features \u003cstrong data-start=\"3132\" data-end=\"3159\"\u003ecomplete plastic panels\u003c\/strong\u003e, according to the supplied product description.\u003c\/p\u003e\n\u003ch3 data-section-id=\"zjxypn\" dir=\"auto\" data-start=\"3214\" data-end=\"3240\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3242\" data-end=\"4008\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3242\" data-end=\"3279\"\u003e\n\u003ctr data-start=\"3242\" data-end=\"3279\"\u003e\n\u003cth data-start=\"3242\" data-end=\"3258\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"3258\" data-end=\"3279\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eTechnical Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3290\" data-end=\"4008\"\u003e\n\u003ctr data-start=\"3290\" data-end=\"3338\"\u003e\n\u003ctd data-start=\"3290\" data-end=\"3304\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3292\" data-end=\"3303\"\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3304\" data-end=\"3338\" data-col-size=\"sm\"\u003eMedinain Suction Apparatus 25D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3339\" data-end=\"3373\"\u003e\n\u003ctd data-start=\"3339\" data-end=\"3360\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3341\" data-end=\"3359\"\u003eOperation Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3360\" data-end=\"3373\" data-col-size=\"sm\"\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3374\" data-end=\"3405\"\u003e\n\u003ctd data-start=\"3374\" data-end=\"3390\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3376\" data-end=\"3389\"\u003ePump Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3390\" data-end=\"3405\" data-col-size=\"sm\"\u003ePiston Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3406\" data-end=\"3436\"\u003e\n\u003ctd data-start=\"3406\" data-end=\"3424\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3408\" data-end=\"3423\"\u003ePump Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3424\" data-end=\"3436\" data-col-size=\"sm\"\u003eOil-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3437\" data-end=\"3468\"\u003e\n\u003ctd data-start=\"3437\" data-end=\"3456\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3439\" data-end=\"3455\"\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3456\" data-end=\"3468\" data-col-size=\"sm\"\u003eElectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3469\" data-end=\"3500\"\u003e\n\u003ctd data-start=\"3469\" data-end=\"3483\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3471\" data-end=\"3482\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3483\" data-end=\"3500\" data-col-size=\"sm\"\u003eAC 220V ± 22V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3501\" data-end=\"3533\"\u003e\n\u003ctd data-start=\"3501\" data-end=\"3517\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3503\" data-end=\"3516\"\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3517\" data-end=\"3533\" data-col-size=\"sm\"\u003e50 Hz ± 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3534\" data-end=\"3566\"\u003e\n\u003ctd data-start=\"3534\" data-end=\"3561\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3536\" data-end=\"3560\"\u003eNumber of Glass Jars\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3561\" data-end=\"3566\" data-col-size=\"sm\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3567\" data-end=\"3592\"\u003e\n\u003ctd data-start=\"3567\" data-end=\"3579\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3569\" data-end=\"3578\"\u003eNoise\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3579\" data-end=\"3592\" data-col-size=\"sm\"\u003e≤65 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3593\" data-end=\"3620\"\u003e\n\u003ctd data-start=\"3593\" data-end=\"3610\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3595\" data-end=\"3609\"\u003eMax Vacuum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3610\" data-end=\"3620\" data-col-size=\"sm\"\u003e90 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3621\" data-end=\"3668\"\u003e\n\u003ctd data-start=\"3621\" data-end=\"3655\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3623\" data-end=\"3654\"\u003eMax Negative Pressure Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3655\" data-end=\"3668\" data-col-size=\"sm\"\u003e\u0026gt;0.09 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3669\" data-end=\"3706\"\u003e\n\u003ctd data-start=\"3669\" data-end=\"3689\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3671\" data-end=\"3688\"\u003eTube Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3689\" data-end=\"3706\" data-col-size=\"sm\"\u003eSilicone Pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3707\" data-end=\"3739\"\u003e\n\u003ctd data-start=\"3707\" data-end=\"3726\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3709\" data-end=\"3725\"\u003ePumping Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3726\" data-end=\"3739\" data-col-size=\"sm\"\u003e≥20 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3740\" data-end=\"3763\"\u003e\n\u003ctd data-start=\"3740\" data-end=\"3752\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3742\" data-end=\"3751\"\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3752\" data-end=\"3763\" data-col-size=\"sm\"\u003e≤180 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3764\" data-end=\"3786\"\u003e\n\u003ctd data-start=\"3764\" data-end=\"3777\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3766\" data-end=\"3776\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3777\" data-end=\"3786\" data-col-size=\"sm\"\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3787\" data-end=\"3816\"\u003e\n\u003ctd data-start=\"3787\" data-end=\"3809\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3789\" data-end=\"3808\"\u003eContinuity Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3809\" data-end=\"3816\" data-col-size=\"sm\"\u003e50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3817\" data-end=\"3871\"\u003e\n\u003ctd data-start=\"3817\" data-end=\"3842\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3819\" data-end=\"3841\"\u003eOperation Controls\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3842\" data-end=\"3871\" data-col-size=\"sm\"\u003eHand switch + foot switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3872\" data-end=\"3930\"\u003e\n\u003ctd data-start=\"3872\" data-end=\"3898\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3874\" data-end=\"3897\"\u003ePressure Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3898\" data-end=\"3930\" data-col-size=\"sm\"\u003eAdjustable negative pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3931\" data-end=\"3964\"\u003e\n\u003ctd data-start=\"3931\" data-end=\"3957\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3933\" data-end=\"3956\"\u003eOverflow Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3957\" data-end=\"3964\" data-col-size=\"sm\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3965\" data-end=\"4008\"\u003e\n\u003ctd data-start=\"3965\" data-end=\"3995\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3967\" data-end=\"3994\"\u003eReverse-Flow Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3995\" data-end=\"4008\" data-col-size=\"sm\"\u003eSpecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medinain","offers":[{"title":"Default Title","offer_id":53392192831669,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Medinain-Suction-Apparatus-25D-Oil-Free-Medical-Suction.jpg?v=1790589664","url":"https:\/\/healthyantrastore.com\/products\/medinain-suction-apparatus-25d","provider":"Health Yantra Store","version":"1.0","type":"link"}