{"product_id":"medisys-neocare-neonatal-ventilator","title":"Medisys Neocare Neonatal Ventilator","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eRefurbished Medisys Neocare Neonatal Ventilator\u003c\/strong\u003e is a \u003cstrong\u003emicro-controller-based, continuous-flow mechanical ventilator\u003c\/strong\u003e designed specifically for \u003cstrong\u003eneonatal, infant, and pediatric patients\u003c\/strong\u003e. It incorporates both \u003cstrong\u003epressure-limiting and volume-limiting mechanisms\u003c\/strong\u003e to help protect fragile lungs from excessive airway pressure and delivered volume.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Neocare provides a tidal-volume range of \u003cstrong\u003e6–300 mL\u003c\/strong\u003e, flow from \u003cstrong\u003e2–25 L\/min\u003c\/strong\u003e, and respiratory rates from \u003cstrong\u003e1–150 breaths per minute\u003c\/strong\u003e, making it suitable for ventilation across a broad range of neonatal and pediatric requirements.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003e12.1-inch graphical LCD\u003c\/strong\u003e provides simultaneous visualization of pressure and flow curves. The ventilator also incorporates \u003cstrong\u003eapnea backup ventilation\u003c\/strong\u003e, sensitive proximal flow and pressure triggering, and a \u003cstrong\u003eservo-controlled oxygen blender\u003c\/strong\u003e with automatic sensor calibration and closed-loop feedback for controlled FiO₂ delivery.\u003c\/p\u003e\n\u003cp\u003eThe compact core ventilator module weighs approximately \u003cstrong\u003e8.2 kg\u003c\/strong\u003e and operates from \u003cstrong\u003e220–240 VAC\u003c\/strong\u003e, with an approximately \u003cstrong\u003e3-hour built-in battery backup\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeonatal-Specific Ventilation:\u003c\/strong\u003e Designed for neonates, infants, and pediatric patients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous-Flow Ventilation:\u003c\/strong\u003e Micro-controller-based continuous-flow architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure \u0026amp; Volume Limiting:\u003c\/strong\u003e Provides mechanisms intended to help reduce the risk of pressure- and volume-related lung injury.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Tidal Volume Range:\u003c\/strong\u003e \u003cstrong\u003e6–300 mL\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad Respiratory Rate Range:\u003c\/strong\u003e \u003cstrong\u003e1–150 breaths\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow Range:\u003c\/strong\u003e \u003cstrong\u003e2–25 L\/min\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Ventilation Modes:\u003c\/strong\u003e AC, SIMV\/IMV, CPAP with backup ventilation, and Standby.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Apnea Backup:\u003c\/strong\u003e Automatically transitions to backup ventilation during apnea episodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensitive Patient Triggering:\u003c\/strong\u003e Uses both flow and pressure triggering through proximal patient sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eServo-Controlled Oxygen Blender:\u003c\/strong\u003e Provides controlled oxygen mixing for FiO₂ delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Sensor Calibration:\u003c\/strong\u003e Oxygen-control system incorporates automatic sensor calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Loop FiO₂ Feedback:\u003c\/strong\u003e Feedback control is designed to support accurate oxygen concentration delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12.1-Inch Graphical LCD:\u003c\/strong\u003e Displays pressure and flow curves simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Battery:\u003c\/strong\u003e Approximately \u003cstrong\u003e3 hours\u003c\/strong\u003e of battery backup according to the supplied specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Lightweight:\u003c\/strong\u003e Core ventilator module weighs approximately \u003cstrong\u003e8.2 kg\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefurbished \u0026amp; Tested:\u003c\/strong\u003e A practical option for facilities requiring neonatal and pediatric respiratory support equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNeonatal \u0026amp; Pediatric Ventilation\u003c\/h3\u003e\n\u003cp\u003eThe Medisys Neocare is specifically designed for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eNeonates\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInfants\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePediatric patients\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts low tidal-volume capability, sensitive triggering, continuous-flow architecture, and pressure\/volume limiting mechanisms are designed around the requirements of ventilation in smaller and more vulnerable patients.\u003c\/p\u003e\n\u003cp\u003eClinical parameters must be selected by appropriately qualified neonatal\/pediatric healthcare professionals according to patient condition and applicable clinical protocols.\u003c\/p\u003e\n\u003ch3\u003ePressure \u0026amp; Volume Limiting\u003c\/h3\u003e\n\u003cp\u003eThe ventilator incorporates both \u003cstrong\u003epressure-limiting and volume-limiting mechanisms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThese systems are intended to help reduce the potential for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExcessive airway pressure\u003c\/li\u003e\n\u003cli\u003eExcessive delivered volume\u003c\/li\u003e\n\u003cli\u003ePressure-related lung injury\u003c\/li\u003e\n\u003cli\u003eVolume-related lung injury\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe actual protective effect depends on appropriate ventilator setup, patient monitoring, clinical settings, and proper use of the equipment.\u003c\/p\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003cp\u003eThe Neocare supports multiple ventilation modes:\u003c\/p\u003e\n\u003ch3\u003eAC – Assist\/Control\u003c\/h3\u003e\n\u003cp\u003eProvides assisted or controlled ventilation for patients requiring mandatory respiratory support.\u003c\/p\u003e\n\u003ch3\u003eSIMV\/IMV\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronized Intermittent Mandatory Ventilation (SIMV)\u003c\/strong\u003e and \u003cstrong\u003eIntermittent Mandatory Ventilation (IMV)\u003c\/strong\u003e modes provide mandatory breaths while accommodating the patient's spontaneous respiratory activity according to the selected configuration.\u003c\/p\u003e\n\u003ch3\u003eCPAP with Backup Ventilation\u003c\/h3\u003e\n\u003cp\u003eCPAP provides continuous positive airway pressure, with backup ventilation available to provide respiratory support during apnea according to the configured system settings.\u003c\/p\u003e\n\u003ch3\u003eStandby\u003c\/h3\u003e\n\u003cp\u003eStandby mode allows the ventilator to remain ready without delivering normal active ventilation.\u003c\/p\u003e\n\u003ch3\u003eSensitive Proximal Triggering\u003c\/h3\u003e\n\u003cp\u003eThe Neocare uses \u003cstrong\u003eproximal patient sensing\u003c\/strong\u003e and combines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eFlow triggering\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePressure triggering\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis sensitive triggering system is designed to detect patient respiratory efforts and support synchronized ventilator response.\u003c\/p\u003e\n\u003cp\u003eFor neonatal patients, where spontaneous respiratory efforts can be small, sensitive triggering can be particularly important for appropriate patient-ventilator interaction.\u003c\/p\u003e\n\u003ch3\u003eServo-Controlled Oxygen Blender\u003c\/h3\u003e\n\u003cp\u003eThe ventilator incorporates a \u003cstrong\u003eservo-controlled oxygen blender\u003c\/strong\u003e designed to provide controlled FiO₂ delivery.\u003c\/p\u003e\n\u003cp\u003eThe oxygen-control system includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic sensor calibration\u003c\/li\u003e\n\u003cli\u003eClosed-loop feedback\u003c\/li\u003e\n\u003cli\u003eServo-controlled oxygen blending\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration is designed to help maintain accurate oxygen concentration according to the selected settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eMedisys Neocare\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eNeonatal\/Pediatric Ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eRefurbished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eMicro-controller-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation Type\u003c\/td\u003e\n\u003ctd\u003eContinuous Flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Category\u003c\/td\u003e\n\u003ctd\u003eNeonatal, Infant \u0026amp; Pediatric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTidal Volume\u003c\/td\u003e\n\u003ctd\u003e6–300 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Range\u003c\/td\u003e\n\u003ctd\u003e2–25 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRespiratory Rate\u003c\/td\u003e\n\u003ctd\u003e1–150 breaths\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVentilation Modes\u003c\/td\u003e\n\u003ctd\u003eAC, SIMV\/IMV, CPAP + Backup, Standby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApnea Backup\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Triggering\u003c\/td\u003e\n\u003ctd\u003eFlow + Pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePatient Sensing\u003c\/td\u003e\n\u003ctd\u003eProximal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen Control\u003c\/td\u003e\n\u003ctd\u003eServo-controlled oxygen blender\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic sensor calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiO₂ Control\u003c\/td\u003e\n\u003ctd\u003eClosed-loop feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e12.1-inch Graphical LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveforms\u003c\/td\u003e\n\u003ctd\u003ePressure \u0026amp; Flow Curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eApprox. 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Module Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Medisys","offers":[{"title":"Default Title","offer_id":53231199846581,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/ab_39.jpg?v=1788849004","url":"https:\/\/healthyantrastore.com\/products\/medisys-neocare-neonatal-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}