{"product_id":"meril-autoquant-200-excelus-fully-automated-biochemistry-analyzer","title":"Meril AutoQuant 200 Excelus Fully Automated Biochemistry Analyzer","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe \u003cstrong\u003eMeril AutoQuant 200\u003c\/strong\u003e Excelus Fully Automated Biochemistry Analyzer is a compact, fully automated biochemistry analyzer designed to support high-throughput laboratories. With a throughput of up to \u003cstrong\u003e200 tests per hour,\u003c\/strong\u003e it features advanced software for managing reflex tests, priority samples, and minimizing cross-contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe analyzer includes onboard reagent cooling, a built-in reagent wash system, reusable cuvettes, and three wash modes to handle forbidden-pair tests and reduce carry-over. Its ceramic-block piston supports precise volume measurement, while software-based reflex testing and STAT sampling help manage laboratory workflows efficiently.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTest Menu\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlbumin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCreatinine\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUrea and Uric Acid\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLipid Profile: HDL, LDL, Triglycerides\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLDH, GGT, ALP, Phosphorus, Magnesium\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCRP and Microalbumin\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdditional biochemistry tests through available system-packs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eKey Highlights\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThroughput of approximately 200 tests per hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional ISE with throughput of up to 300 tests per hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOnboard reagent cooling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in reagent wash system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree wash modes to handle forbidden-pair tests and reduce carry-over\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSoftware-based reflex testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePriority (STAT) sampling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePrecise volume measurement with a ceramic-block piston\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e60 reusable reaction cuvettes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOnboard seven-step cuvette washing system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple analytical methods and assay modes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCalibration with up to six points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic rerun for abnormal marking or range errors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnlimited test-result and reaction-curve storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDaily and monthly quality control with archiving\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.058%; height: 764.158px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalyzer Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eFully automated biochemistry analyzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eThroughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e200 tests\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eISE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eOptional; up to 300 tests\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eAnalysis Methods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003eEnd Point, Fixed Time (2-point), Kinetic Rate-A, Kinetic Rate-B, Sample\/Reagent Blanking, ISE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eAssay Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003eColorimetry, Turbidimetry, Single and Double Reagent, Multi-Standard, Mono and Bi-Chromatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eSample Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eSerum, Plasma, Urine, CSF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eReagent Positions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e45 each for R1 and R2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eMixing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003ePaddle or separate disperser\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eReaction Cuvettes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e60 reusable cuvettes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eCuvette Washing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eOnboard seven-step washing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eReaction Time, Two-Reagent Chemistry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003e30–300 seconds per reagent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eReaction Time, One-Reagent Chemistry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003e30–600 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasurement Principle\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003ePhotometry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eLight Source\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003eTungsten halogen lamp, 12 V, 20 W, with cooling and automatic on\/off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eWavelengths\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e9 filters: 340, 405, 450, 510, 548, 578, 620, 670 and 700 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eDetector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eSilicon photodiode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 39.1875px;\"\u003e\u003cspan\u003eCalibration Modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 39.1875px;\"\u003e\u003cspan\u003eK-Factor, Linear, Multi-point, Logit-log, Spline, Exponential, Polynomial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eCalibration Points\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eUp to 6 points, with repeat-run list or auto-execution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eAutomatic Rerun\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eAvailable for abnormal marking or range error\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eQuality Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eDaily and monthly QC with archiving\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e110\/220 VAC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eMaximum Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e250 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e10°C–30°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eHumidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e40–80%, with no water dew formation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eOperating System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eWindows XP, Windows 7, Windows 8, Windows 10, or Win7x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eInput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eMultifunctional keypad\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eOutput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003eRS-232 interface \/ printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eDimensions (L × W × H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e73.6 × 55.3 × 43.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 30.5946%; height: 19.5938px;\"\u003e\u003cspan\u003eApproximate Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.9211%; height: 19.5938px;\"\u003e\u003cspan\u003e55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003eProduct Disclaimer\u003c\/h2\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Meril Life Sciences","offers":[{"title":"Default Title","offer_id":53581649248437,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Meril-AutoQuant-200-Excelus-Biochemistry-Analyzer.jpg?v=1792653399","url":"https:\/\/healthyantrastore.com\/products\/meril-autoquant-200-excelus-fully-automated-biochemistry-analyzer","provider":"Health Yantra Store","version":"1.0","type":"link"}