{"product_id":"mindray-bs-240-pro-fully-automatic-chemistry-analyzer","title":"Mindray BS-240 Pro Fully Automatic Chemistry Analyzer","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMindray BS-240 Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a fully automatic clinical chemistry analyzer with a photometric throughput of 240 tests per hour and throughput of up to 400 tests per hour when equipped with the optional ISE module. Its compact benchtop design makes it suitable for laboratories with limited space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Mindray \u003cstrong\u003eBS-240 Pro\u003c\/strong\u003e chemistry analyzer supports absorbance photometry, turbidimetry, and optional ISE. It features bi-directional \u003cstrong\u003eLaboratory Information System (LIS)\u003c\/strong\u003e connectivity, open or closed reagent systems, an intelligent probe with liquid-level detection and collision protection, and reusable reaction cuvettes with automatic washing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of Mindray BS-240 Pro\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFully automatic, discrete, random-access benchtop chemistry analyzer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhotometric throughput of 240 tests per hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUp to 400 tests per hour with the optional ISE module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact design for space-limited laboratories\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBi-directional LIS connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports open and closed reagent systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntelligent probe with liquid-level detection and collision protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e80 reusable reaction cuvettes with automatic washing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomatic pre-dilution and post-dilution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple calibration methods\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.058%; height: 431.063px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eMindray BS-240 Pro\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalyzer Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eFully Automatic Chemistry Analyzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eSystem\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eAutomatic, discrete, random access, bench-top\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 39.1875px;\"\u003e\u003cspan\u003ePhotometric Throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 39.1875px;\"\u003e\u003cspan\u003e240 tests\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 39.1875px;\"\u003e\u003cspan\u003eThroughput with Optional ISE\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 39.1875px;\"\u003e\u003cspan\u003eUp to 400 tests\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasuring Principles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eAbsorbance photometry, turbidimetry, optional ISE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eReagent System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eOpen or closed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eR1 Reagent Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003e100–200 µL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eR2 Reagent Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003e10–200 µL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eSample Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eAs low as 2 µL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eReaction Tray\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003e80 reusable cuvettes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eAutomatic Dilution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003ePre-dilution and post-dilution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eWavelengths\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003e340, 380, 412, 450, 505, 546, 570, 605, 660, 700, 740, and 800 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 39.1875px;\"\u003e\u003cspan\u003eQuality Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 39.1875px;\"\u003e\u003cspan\u003eWestgard multi-rule, Levey-Jennings, cumulative sum, and twin plot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eLIS Connectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003eBi-directional\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.8159%; height: 19.5938px;\"\u003e\u003cspan\u003eWater Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 71.6998%; height: 19.5938px;\"\u003e\u003cspan\u003e≤6.5 L\/hour\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eProduct Disclaimer\u003c\/h2\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"Mindray","offers":[{"title":"Default Title","offer_id":53542274465973,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Mindray-BS-240-Pro-Fully-Automatic-Chemistry-Analyzer-for-Clinical-Laboratories.jpg?v=1792240489","url":"https:\/\/healthyantrastore.com\/products\/mindray-bs-240-pro-fully-automatic-chemistry-analyzer","provider":"Health Yantra Store","version":"1.0","type":"link"}