{"product_id":"nidek-babymag-neonatal-and-pediatric-ventilator","title":"Nidek BABYMAG Neonatal and Pediatric Ventilator","description":"\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNidek BABYMAG Neonatal and Pediatric Ventilator\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a dedicated ventilatory support system designed for premature infants, neonates and pediatric patients. Developed for demanding Neonatal Intensive Care Unit (NICU) environments, BABYMAG combines advanced ventilation technology with a simple, intuitive interface to support healthcare professionals in managing neonatal and pediatric respiratory care.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ventilator supports multiple ventilation modes, including volume-controlled ventilation (VCV), pressure-controlled ventilation (PCV), pressure-regulated volume control (PRVC), synchronized intermittent mandatory ventilation (SIMV), continuous positive airway pressure (CPAP), pressure support ventilation (PSV), and non-invasive ventilation (NIV).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-inch touchscreen display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, proximal flow sensing and graphical monitoring with curves and loops, the Nidek BABYMAG is designed to facilitate respiratory monitoring and ventilation management. It also supports capnography and oximetry with Masimo technology and provides approximately four hours of battery backup, according to the supplied product information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features of Nidek BABYMAG\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDedicated neonatal and pediatric ventilation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for premature infants, neonates and pediatric patients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMultiple ventilation modes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports a wide range of invasive and non-invasive ventilation modes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e15-inch touchscreen:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides a large display for accessing controls and monitoring respiratory parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProximal flow sensing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for quick response and accurate flow measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNon-invasive ventilation (NIV):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports NIV across the listed ventilator modes, as stated in the supplied description.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCPAP support:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes CPAP with respiratory rate adjustment, according to the product information.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMasimo technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Supports capnography and oximetry measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRespiratory graphics:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Displays curves and loops to support ventilation assessment and weaning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBattery backup:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately four hours of backup, according to the supplied information.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eQuick-charging batteries:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to support battery charging and operational readiness.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAvailable Ventilation Modes\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eMode\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVCV \/ VCV-AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVolume-controlled ventilation and assist-control variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePCV \/ PCV-AC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure-controlled ventilation and assist-control variant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePRVC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure-regulated volume control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePLV \/ PLV with VG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModes listed by the manufacturer; confirm exact mode definitions and configuration with the supplier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eV-SIMV + PS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVolume SIMV with pressure support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eP-SIMV + PS\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure SIMV with pressure support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDual PAP \/ APRV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual positive airway pressure \/ airway pressure release ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCPAP \/ PSV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous positive airway pressure \/ pressure support ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMMV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMandatory minute ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNIV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-invasive ventilation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNidek\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBABYMAG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNeonatal and pediatric ventilator\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended patient groups\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePremature infants, neonates and pediatric patients\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15-inch touchscreen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVentilation modes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVCV\/VCV-AC, PCV\/PCV-AC, PRVC, PLV\/PLV with VG, V-SIMV+PS, P-SIMV+PS, Dual PAP\/APRV, CPAP\/PSV, MMV, NIV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFlow sensing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProximal flow sensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCapnography\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported with Masimo technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOximetry\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupported with Masimo technology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGraphics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurves and loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNIV support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAvailable, according to the supplied product description\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCPAP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes respiratory rate adjustment, according to the supplied description\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery backup\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 4 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBattery charging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eQuick-charging batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot provided in the supplied product information\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eClinical Applications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Nidek BABYMAG is designed for respiratory support applications involving:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeonatal Intensive Care Units (NICUs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePremature infant respiratory care\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNeonatal respiratory support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePediatric intensive care\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInvasive ventilation, where clinically indicated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNon-invasive respiratory support, where clinically indicated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRespiratory monitoring and weaning assessment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eVentilator mode selection, settings and monitoring must be determined by qualified healthcare professionals according to the patient's condition and applicable clinical protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBenefits for NICU and Pediatric Care\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eDesigned for Small and Vulnerable Patients\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe BABYMAG is specifically intended for premature, neonatal and pediatric applications rather than being described as a general adult ventilator.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Nidek","offers":[{"title":"Default Title","offer_id":53500211036341,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Nidek-BABYMAG-Neonatal-and-Pediatric-Ventilator.png?v=1791538513","url":"https:\/\/healthyantrastore.com\/products\/nidek-babymag-neonatal-and-pediatric-ventilator","provider":"Health Yantra Store","version":"1.0","type":"link"}