{"product_id":"puritan-bennett-840-ventilator-icu-ventilator-for-neonatal-pediatric-adult-patients","title":"Puritan Bennett 840 Ventilator – ICU Ventilator for Neonatal, Pediatric \u0026 Adult Patients","description":"\u003cp\u003eThe \u003cstrong\u003eRefurbished Puritan Bennett 840 Ventilator\u003c\/strong\u003e is an advanced intensive care ventilator designed to provide flexible mechanical ventilation for \u003cstrong\u003eneonatal, pediatric, and adult patients\u003c\/strong\u003e. The system features \u003cstrong\u003edual-microprocessor control, DualView™ touchscreen interfaces, and flexible breath-delivery technologies\u003c\/strong\u003e for critical-care environments.\u003c\/p\u003e\n\u003cp\u003eThe Puritan Bennett 840 platform combines patient monitoring and ventilator control through separate touchscreen displays and can be configured with ventilation modes and software options such as \u003cstrong\u003ePAV+™, Volume Ventilation Plus, NeoMode, and Tube Compensation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePuritan Bennett 840\u003c\/strong\u003e is an ICU-grade mechanical ventilator built around a modular system architecture. Its ventilator base incorporates the blower\/exhalation unit, while the system can be configured with an optional compressor, breathing circuit components, and an external Backup Power Source (BPS).\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDualView™ Graphic User Interface (GUI)\u003c\/strong\u003e separates patient-data monitoring from ventilator-setting controls, providing clinicians with dedicated touchscreen areas for viewing patient information and managing ventilation settings.\u003c\/p\u003e\n\u003ch3\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Puritan Bennett\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 840\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition:\u003c\/strong\u003e \u003cstrong\u003eRefurbished\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced ICU mechanical ventilator\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003eneonatal, pediatric, and adult\u003c\/strong\u003e patients\u003c\/li\u003e\n\u003cli\u003eDual-microprocessor control\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDualView™ touchscreen GUI\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSeparate patient monitoring and ventilator-control interfaces\u003c\/li\u003e\n\u003cli\u003eFlexible breath delivery\u003c\/li\u003e\n\u003cli\u003eAssist\/Control (A\/C)\u003c\/li\u003e\n\u003cli\u003eSIMV\u003c\/li\u003e\n\u003cli\u003eSpontaneous (SPONT)\u003c\/li\u003e\n\u003cli\u003eBiLevel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePAV+™\u003c\/strong\u003e software option\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVolume Ventilation Plus\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeoMode\u003c\/strong\u003e software option\u003c\/li\u003e\n\u003cli\u003eTube Compensation\u003c\/li\u003e\n\u003cli\u003eOptional medical-grade compressor\u003c\/li\u003e\n\u003cli\u003eExternal Backup Power Source (BPS)\u003c\/li\u003e\n\u003cli\u003eModular breathing-circuit configuration\u003c\/li\u003e\n\u003cli\u003eDesigned for critical-care\/ICU applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDualView™ Graphic User Interface\u003c\/h3\u003e\n\u003cp\u003eThe Puritan Bennett 840 incorporates a \u003cstrong\u003eDualView™ touchscreen interface\u003c\/strong\u003e designed to separate two important functions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePatient data monitoring\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eVentilator setting controls\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration allows clinicians to view patient-related information while accessing ventilation controls through dedicated touchscreen interfaces.\u003c\/p\u003e\n\u003ch3\u003eDual-Microprocessor Ventilator Control\u003c\/h3\u003e\n\u003cp\u003eThe ventilator base incorporates \u003cstrong\u003edual microprocessors\u003c\/strong\u003e that support the system's ventilator-control architecture.\u003c\/p\u003e\n\u003cp\u003eThe ventilator base also houses:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBlower\/exhalation unit\u003c\/li\u003e\n\u003cli\u003eExhalation filter\u003c\/li\u003e\n\u003cli\u003eCollection bottle unit\u003c\/li\u003e\n\u003cli\u003eDual microprocessors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis integrated architecture forms the central ventilator platform.\u003c\/p\u003e\n\u003ch3\u003eVentilation Modes\u003c\/h3\u003e\n\u003ch3\u003eAssist\/Control (A\/C)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAssist\/Control mode\u003c\/strong\u003e provides mandatory ventilation while allowing patient-triggered breaths according to the configured ventilation settings.\u003c\/p\u003e\n\u003ch3\u003eSynchronized Intermittent Mandatory Ventilation (SIMV)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSIMV\u003c\/strong\u003e delivers synchronized mandatory breaths while allowing spontaneous breathing between mandatory breaths.\u003c\/p\u003e\n\u003ch3\u003eSpontaneous (SPONT)\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSpontaneous mode\u003c\/strong\u003e supports spontaneous patient breathing according to the selected ventilator configuration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eAdvanced Software \u0026amp; Ventilation Options\u003c\/h3\u003e\n\u003ch3\u003ePAV+™\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePAV+™ (Proportional Assist Ventilation)\u003c\/strong\u003e is designed to track patient effort and provide proportional ventilatory assistance, supporting a more natural breathing pattern.\u003c\/p\u003e\n\u003ch3\u003eVolume Ventilation Plus\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVolume Ventilation Plus\u003c\/strong\u003e option combines:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVolume Control Plus\u003c\/li\u003e\n\u003cli\u003eVolume Support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis provides additional flexibility for volume-targeted and supported ventilation.\u003c\/p\u003e\n\u003ch3\u003eTube Compensation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eTube Compensation\u003c\/strong\u003e feature automatically offsets flow-dependent pressure drops associated with artificial airways.\u003c\/p\u003e\n\u003ch3\u003eCore System Components\u003c\/h3\u003e\n\u003ch3\u003e1. Graphic User Interface (GUI)\u003c\/h3\u003e\n\u003cp\u003eThe DualView™ GUI incorporates dual touchscreens that separate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatient data monitoring\u003c\/li\u003e\n\u003cli\u003eVentilator setting controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e2. Ventilator Base\u003c\/h3\u003e\n\u003cp\u003eThe ventilator base, incorporating the blower\/exhalation unit, contains:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual microprocessors\u003c\/li\u003e\n\u003cli\u003eExhalation filter\u003c\/li\u003e\n\u003cli\u003eCollection bottle unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e3. Optional Compressor\u003c\/h3\u003e\n\u003cp\u003eAn optional compressor can provide an \u003cstrong\u003eindependent medical-grade compressed gas source\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e4. Breathing Circuit\u003c\/h3\u003e\n\u003cp\u003eThe breathing circuit configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInspiratory limb\u003c\/li\u003e\n\u003cli\u003eExpiratory limb\u003c\/li\u003e\n\u003cli\u003eFilters\u003c\/li\u003e\n\u003cli\u003eWater traps\u003c\/li\u003e\n\u003cli\u003eHumidifier pot\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e5. Backup Power Source (BPS)\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBackup Power Source\u003c\/strong\u003e is an external battery module designed to provide emergency power during situations such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransport\u003c\/li\u003e\n\u003cli\u003ePower interruption\u003c\/li\u003e\n\u003cli\u003eLoss of primary electrical power\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePuritan Bennett\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRefurbished\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntensive Care Ventilator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatient Categories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeonatal, Pediatric \u0026amp; Adult\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDualView™ Touchscreens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGUI Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePatient monitoring + ventilator controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\/C, SIMV, SPONT, BiLevel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePAV+™\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable as software option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume Ventilation Plus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeoMode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable as software option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeoMode IBW Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDown to 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTube Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal BPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreathing Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInspiratory\/expiratory limbs, filters, water traps, humidifier pot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICU \/ Critical Care\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Puritan Bennett","offers":[{"title":"Default Title","offer_id":53237617623221,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Refurbished-Puritan-Bennett-840-Ventilator.jpg?v=1788943509","url":"https:\/\/healthyantrastore.com\/products\/puritan-bennett-840-ventilator-icu-ventilator-for-neonatal-pediatric-adult-patients","provider":"Health Yantra Store","version":"1.0","type":"link"}