{"product_id":"rms-analytica-705-semi-automatic-biochemistry-analyzer","title":"RMS Analytica 705 Semi-Automatic Biochemistry Analyzer","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRMS Analytica 705\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a semi-automatic biochemistry analyzer designed for routine clinical chemistry testing. With support for 248 programmable tests, 48 direct test keys, multiple measurement methods, and a wide range of clinical chemistry test profiles, it supports biochemical testing in clinical laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe RMS Analytica 705 features a 30 µL quartz flow cell, seven measurement wavelengths, a built-in thermal printer, and memory for up to \u003cstrong\u003e100,000 test results.\u003c\/strong\u003e Its direct-access keys, programmable test profiles, and calibrated peristaltic pump support convenient testing workflows and reagent-use management.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features of RMS Analytica 705\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSemi-automatic biochemistry analyzer for routine clinical chemistry testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports 248 programmable tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e48 direct test keys for quick access to tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports whole blood, serum, plasma, CSF, and urine samples\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEndpoint, fixed-time, kinetic, bichromatic, and absorbance measurement methods\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeven wavelengths: 340, 405, 505, 546, 578, 620, and 670 nm\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature settings for room temperature, 25°C, 30°C, and 37°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThree controls per test with Levey-Jennings graph\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS-232 and USB connectivity options\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCalibrated peristaltic pump to help reduce reagent use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect flow-cell rinsing during testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultiple test profiles and reaction result monitoring during testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"width: 100.058%; height: 372.282px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eProduct Name\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eRMS Analytica 705 Biochemistry Analyzer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eRMS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalytica 705\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eAnalyzer Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eSemi-Automatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eProgrammable Tests\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003e248\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eDirect Test Keys\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003e48\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eSample Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eWhole blood, serum, plasma, CSF, urine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eMeasurement Methods\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eEndpoint, fixed-time, kinetic, bichromatic, absorbance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eWavelengths\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003e340, 405, 505, 546, 578, 620, 670 nm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eTemperature Settings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eRoom temperature, 25°C, 30°C, 37°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eQuality Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003e3 controls per test with Levey-Jennings graph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eUp to 100,000 test results\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003ePrinter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eBuilt-in thermal printer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eRS-232 and USB options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eReagent Management\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eCalibrated peristaltic pump\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 29.6161%; height: 19.5938px;\"\u003e\u003cspan\u003eFlow Cell Cleaning\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.8997%; height: 19.5938px;\"\u003e\u003cspan\u003eDirect rinsing during testing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch2\u003eProduct Disclaimer\u003c\/h2\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e","brand":"RMS","offers":[{"title":"Default Title","offer_id":53556625768629,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/RMS-Analytica-705-Semi-Automatic-Biochemistry-Analyzer-for-Clinical-Laboratories.jpg?v=1792394517","url":"https:\/\/healthyantrastore.com\/products\/rms-analytica-705-semi-automatic-biochemistry-analyzer","provider":"Health Yantra Store","version":"1.0","type":"link"}