{"product_id":"santron-pc-based-wireless-uroflowmeter-sanuro4wl","title":"Santron PC-Based Wireless Uroflowmeter – SANURO4WL","description":"\u003cp dir=\"auto\" data-start=\"54\" data-end=\"421\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"58\" data-end=\"119\"\u003eSantron PC-Based Wireless Uroflowmeter (Model: SANURO4WL)\u003c\/strong\u003e is a wireless uroflowmetry system designed to provide fast and precise urine flow measurement while supporting efficient clinical workflows. It combines \u003cstrong data-start=\"273\" data-end=\"298\"\u003ewireless connectivity\u003c\/strong\u003e, a \u003cstrong data-start=\"302\" data-end=\"338\"\u003egravimetric (weight-type) sensor\u003c\/strong\u003e, and \u003cstrong data-start=\"344\" data-end=\"374\"\u003eWindows operating software\u003c\/strong\u003e for convenient PC-based uroflowmetry analysis.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"423\" data-end=\"687\"\u003eThe system measures \u003cstrong data-start=\"443\" data-end=\"475\"\u003evoided volume from 0–1000 ml\u003c\/strong\u003e and \u003cstrong data-start=\"480\" data-end=\"511\"\u003eflow rates from 0–50 ml\/sec\u003c\/strong\u003e, with a specified accuracy of \u003cstrong data-start=\"542\" data-end=\"566\"\u003e±2% of voided volume\u003c\/strong\u003e. It supports \u003cstrong data-start=\"580\" data-end=\"612\"\u003eAuto Mode and Hesitancy Mode\u003c\/strong\u003e and provides flow and volume graphs along with \u003cstrong data-start=\"660\" data-end=\"686\"\u003estandard ICS nomograms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"689\" data-end=\"706\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"708\" data-end=\"1160\"\u003e\n\u003cli data-section-id=\"hlojmu\" data-start=\"708\" data-end=\"730\"\u003e\n\u003cstrong data-start=\"710\" data-end=\"720\"\u003eModel:\u003c\/strong\u003e SANURO4WL\u003c\/li\u003e\n\u003cli data-section-id=\"1agrp8v\" data-start=\"731\" data-end=\"770\"\u003ePC-based wireless uroflowmetry system\u003c\/li\u003e\n\u003cli data-section-id=\"ihk8j1\" data-start=\"771\" data-end=\"798\"\u003e\u003cstrong data-start=\"773\" data-end=\"798\"\u003eWireless connectivity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1p3cob7\" data-start=\"799\" data-end=\"834\"\u003eVolume measurement: \u003cstrong data-start=\"821\" data-end=\"834\"\u003e0–1000 ml\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1n7z4wv\" data-start=\"835\" data-end=\"863\"\u003eFlow rate: \u003cstrong data-start=\"848\" data-end=\"863\"\u003e0–50 ml\/sec\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"127iv9\" data-start=\"864\" data-end=\"902\"\u003e\u003cstrong data-start=\"866\" data-end=\"902\"\u003eGravimetric (weight-type) sensor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"rbm8kd\" data-start=\"903\" data-end=\"939\"\u003eAccuracy: \u003cstrong data-start=\"915\" data-end=\"939\"\u003e±2% of voided volume\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15rjm7r\" data-start=\"940\" data-end=\"972\"\u003e\u003cstrong data-start=\"942\" data-end=\"972\"\u003eAuto Mode \u0026amp; Hesitancy Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"otzgcl\" data-start=\"973\" data-end=\"1001\"\u003eWindows operating software\u003c\/li\u003e\n\u003cli data-section-id=\"b3kadm\" data-start=\"1002\" data-end=\"1028\"\u003eFlow Rate vs. Time graph\u003c\/li\u003e\n\u003cli data-section-id=\"mwj87m\" data-start=\"1029\" data-end=\"1052\"\u003eVolume vs. Time graph\u003c\/li\u003e\n\u003cli data-section-id=\"qfkwmb\" data-start=\"1053\" data-end=\"1081\"\u003eStandard \u003cstrong data-start=\"1064\" data-end=\"1081\"\u003eICS nomograms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"mp152f\" data-start=\"1082\" data-end=\"1134\"\u003eDesigned for fast and precise uroflowmetry results\u003c\/li\u003e\n\u003cli data-section-id=\"161y586\" data-start=\"1135\" data-end=\"1160\"\u003eUser-friendly interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1jud4x4\" dir=\"auto\" data-start=\"1162\" data-end=\"1186\"\u003eWireless Uroflowmetry\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1188\" data-end=\"1460\"\u003eThe \u003cstrong data-start=\"1192\" data-end=\"1225\"\u003eSantron Wireless Uroflowmeter\u003c\/strong\u003e uses wireless connectivity to support communication with the PC-based system. This design helps streamline the uroflowmetry workflow while reducing the need for conventional wired connections between the measurement unit and computer.\u003c\/p\u003e\n\u003ch3 data-section-id=\"w0gwcm\" dir=\"auto\" data-start=\"1462\" data-end=\"1499\"\u003eGravimetric Measurement Technology\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1501\" data-end=\"1713\"\u003eThe SANURO4WL uses a \u003cstrong data-start=\"1522\" data-end=\"1558\"\u003egravimetric (weight-type) sensor\u003c\/strong\u003e to measure urine flow. The specified accuracy is \u003cstrong data-start=\"1608\" data-end=\"1632\"\u003e±2% of voided volume\u003c\/strong\u003e, providing quantitative measurement of urine volume during uroflowmetry testing.\u003c\/p\u003e\n\u003ch3 data-section-id=\"599mvl\" dir=\"auto\" data-start=\"1715\" data-end=\"1748\"\u003eVolume \u0026amp; Flow Rate Measurement\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1750\" data-end=\"1813\"\u003eThe system provides the following specified measurement ranges:\u003c\/p\u003e\n\u003cul data-start=\"1815\" data-end=\"1867\"\u003e\n\u003cli data-section-id=\"5wqptl\" data-start=\"1815\" data-end=\"1838\"\u003e\n\u003cstrong data-start=\"1817\" data-end=\"1828\"\u003eVolume:\u003c\/strong\u003e 0–1000 ml\u003c\/li\u003e\n\u003cli data-section-id=\"os7len\" data-start=\"1839\" data-end=\"1867\"\u003e\n\u003cstrong data-start=\"1841\" data-end=\"1855\"\u003eFlow rate:\u003c\/strong\u003e 0–50 ml\/sec\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1869\" data-end=\"1951\"\u003eThese measurements can be presented through graphical outputs for clinical review.\u003c\/p\u003e\n\u003ch3 data-section-id=\"17992qy\" dir=\"auto\" data-start=\"1953\" data-end=\"1978\"\u003eAuto \u0026amp; Hesitancy Modes\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1980\" data-end=\"2054\"\u003eThe Santron PC-Based Wireless Uroflowmeter provides two measurement modes:\u003c\/p\u003e\n\u003cul data-start=\"2056\" data-end=\"2092\"\u003e\n\u003cli data-section-id=\"ggb8v8\" data-start=\"2056\" data-end=\"2071\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2071\"\u003eAuto Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"cpl21p\" data-start=\"2072\" data-end=\"2092\"\u003e\u003cstrong data-start=\"2074\" data-end=\"2092\"\u003eHesitancy Mode\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2094\" data-end=\"2179\"\u003eThese modes allow the system to support different uroflowmetry measurement workflows.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1epkmkp\" dir=\"auto\" data-start=\"2181\" data-end=\"2206\"\u003eWindows-Based Software\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2208\" data-end=\"2352\"\u003eThe SANURO4WL operates with \u003cstrong data-start=\"2236\" data-end=\"2266\"\u003eWindows operating software\u003c\/strong\u003e, providing a PC-based interface for managing and reviewing uroflowmetry measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"4l58z5\" dir=\"auto\" data-start=\"2354\" data-end=\"2388\"\u003eGraphical Uroflowmetry Analysis\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2390\" data-end=\"2412\"\u003eThe software provides:\u003c\/p\u003e\n\u003cul data-start=\"2414\" data-end=\"2501\"\u003e\n\u003cli data-section-id=\"1kb0qyy\" data-start=\"2414\" data-end=\"2444\"\u003e\u003cstrong data-start=\"2416\" data-end=\"2444\"\u003eFlow Rate vs. Time graph\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1i3hff6\" data-start=\"2445\" data-end=\"2472\"\u003e\u003cstrong data-start=\"2447\" data-end=\"2472\"\u003eVolume vs. Time graph\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"qfkwmb\" data-start=\"2473\" data-end=\"2501\"\u003eStandard \u003cstrong data-start=\"2484\" data-end=\"2501\"\u003eICS nomograms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"2503\" data-end=\"2614\"\u003eThese graphical outputs allow healthcare professionals to review urine flow patterns and recorded measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1cgu054\" dir=\"auto\" data-start=\"2616\" data-end=\"2643\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2645\" data-end=\"3148\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2645\" data-end=\"2672\"\u003e\n\u003ctr data-start=\"2645\" data-end=\"2672\"\u003e\n\u003cth data-start=\"2645\" data-end=\"2661\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2661\" data-end=\"2672\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2683\" data-end=\"3148\"\u003e\n\u003ctr data-start=\"2683\" data-end=\"2735\"\u003e\n\u003ctd data-start=\"2683\" data-end=\"2693\" data-col-size=\"sm\"\u003eProduct\u003c\/td\u003e\n\u003ctd data-start=\"2693\" data-end=\"2735\" data-col-size=\"sm\"\u003eSantron PC-Based Wireless Uroflowmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2736\" data-end=\"2761\"\u003e\n\u003ctd data-start=\"2736\" data-end=\"2744\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2744\" data-end=\"2761\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2746\" data-end=\"2759\"\u003eSANURO4WL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2762\" data-end=\"2794\"\u003e\n\u003ctd data-start=\"2762\" data-end=\"2777\" data-col-size=\"sm\"\u003eVolume Range\u003c\/td\u003e\n\u003ctd data-start=\"2777\" data-end=\"2794\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2779\" data-end=\"2792\"\u003e0–1000 ml\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2795\" data-end=\"2832\"\u003e\n\u003ctd data-start=\"2795\" data-end=\"2813\" data-col-size=\"sm\"\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd data-start=\"2813\" data-end=\"2832\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2815\" data-end=\"2830\"\u003e0–50 ml\/sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2833\" data-end=\"2864\"\u003e\n\u003ctd data-start=\"2833\" data-end=\"2848\" data-col-size=\"sm\"\u003eConnectivity\u003c\/td\u003e\n\u003ctd data-start=\"2848\" data-end=\"2864\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2850\" data-end=\"2862\"\u003eWireless\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2865\" data-end=\"2903\"\u003e\n\u003ctd data-start=\"2865\" data-end=\"2874\" data-col-size=\"sm\"\u003eSensor\u003c\/td\u003e\n\u003ctd data-start=\"2874\" data-end=\"2903\" data-col-size=\"sm\"\u003eGravimetric (Weight) Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2904\" data-end=\"2943\"\u003e\n\u003ctd data-start=\"2904\" data-end=\"2915\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2915\" data-end=\"2943\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2917\" data-end=\"2941\"\u003e±2% of voided volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2944\" data-end=\"2994\"\u003e\n\u003ctd data-start=\"2944\" data-end=\"2964\" data-col-size=\"sm\"\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd data-start=\"2964\" data-end=\"2994\" data-col-size=\"sm\"\u003eAuto Mode \u0026amp; Hesitancy Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2995\" data-end=\"3036\"\u003e\n\u003ctd data-start=\"2995\" data-end=\"3006\" data-col-size=\"sm\"\u003eSoftware\u003c\/td\u003e\n\u003ctd data-start=\"3006\" data-end=\"3036\" data-col-size=\"sm\"\u003eWindows Operating Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3037\" data-end=\"3074\"\u003e\n\u003ctd data-start=\"3037\" data-end=\"3046\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-start=\"3046\" data-end=\"3074\" data-col-size=\"sm\"\u003eFlow Rate vs. Time Graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3075\" data-end=\"3109\"\u003e\n\u003ctd data-start=\"3075\" data-end=\"3084\" data-col-size=\"sm\"\u003eOutput\u003c\/td\u003e\n\u003ctd data-start=\"3084\" data-end=\"3109\" data-col-size=\"sm\"\u003eVolume vs. Time Graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3110\" data-end=\"3148\"\u003e\n\u003ctd data-start=\"3110\" data-end=\"3122\" data-col-size=\"sm\"\u003eReference\u003c\/td\u003e\n\u003ctd data-start=\"3122\" data-end=\"3148\" data-col-size=\"sm\"\u003eStandard ICS Nomograms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Santron","offers":[{"title":"Default Title","offer_id":53412500340917,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Santron-PC-Based-Uroflowmeter-with-Windows-Software.jpg?v=1790927538","url":"https:\/\/healthyantrastore.com\/products\/santron-pc-based-wireless-uroflowmeter-sanuro4wl","provider":"Health Yantra Store","version":"1.0","type":"link"}