{"product_id":"vertical-autoclave-wing-nut-locking-double-wall","title":"Vertical Autoclave Wing Nut Locking Double Wall","description":"\u003cp dir=\"auto\" data-start=\"51\" data-end=\"373\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"55\" data-end=\"106\"\u003eVertical Autoclave Wing Nut Locking Double Wall\u003c\/strong\u003e is a compact vertical steam sterilizer available in \u003cstrong data-start=\"159\" data-end=\"195\"\u003e40-litre and 80-litre capacities\u003c\/strong\u003e. It features double-wall and SS GMP construction, an immersion-type heater, wing-nut locking with pedal lift, digital temperature control and a jointless silicone rubber gasket.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"375\" data-end=\"620\"\u003eThe autoclave is designed for steam sterilization at \u003cstrong data-start=\"428\" data-end=\"446\"\u003e121°C to 134°C\u003c\/strong\u003e, with \u003cstrong data-start=\"453\" data-end=\"501\"\u003e150°C available as an optional configuration\u003c\/strong\u003e. The standard working pressure is \u003cstrong data-start=\"536\" data-end=\"563\"\u003e1.2 kgf\/cm² (15–17 psi)\u003c\/strong\u003e, with the working pressure upgradeable up to \u003cstrong data-start=\"609\" data-end=\"619\"\u003e30 psi\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"622\" data-end=\"800\"\u003eOptional documentation, recording and data-management features include \u003cstrong data-start=\"693\" data-end=\"799\"\u003eIQ\/OQ\/PQ documentation, dot-matrix printer provision, temperature chart recorder and USB data transfer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5ptua8\" dir=\"auto\" data-start=\"802\" data-end=\"819\"\u003e✅ Key Features\u003c\/h3\u003e\n\u003cul data-start=\"821\" data-end=\"1658\"\u003e\n\u003cli data-section-id=\"tig9y\" data-start=\"821\" data-end=\"853\"\u003eVertical double-wall autoclave\u003c\/li\u003e\n\u003cli data-section-id=\"e7y0bn\" data-start=\"854\" data-end=\"895\"\u003eAvailable in \u003cstrong data-start=\"869\" data-end=\"884\"\u003e40L and 80L\u003c\/strong\u003e capacities\u003c\/li\u003e\n\u003cli data-section-id=\"10w70gn\" data-start=\"896\" data-end=\"919\"\u003eImmersion-type heater\u003c\/li\u003e\n\u003cli data-section-id=\"1k62y2v\" data-start=\"920\" data-end=\"955\"\u003eDouble-wall \u0026amp; SS GMP construction\u003c\/li\u003e\n\u003cli data-section-id=\"13bl0qb\" data-start=\"956\" data-end=\"981\"\u003eWing-nut locking system\u003c\/li\u003e\n\u003cli data-section-id=\"1vr7jnl\" data-start=\"982\" data-end=\"1010\"\u003ePedal-assisted lid lifting\u003c\/li\u003e\n\u003cli data-section-id=\"1hpejg0\" data-start=\"1011\" data-end=\"1045\"\u003eJointless silicone rubber gasket\u003c\/li\u003e\n\u003cli data-section-id=\"11qvtxe\" data-start=\"1046\" data-end=\"1078\"\u003eDigital temperature controller\u003c\/li\u003e\n\u003cli data-section-id=\"ehgfmv\" data-start=\"1079\" data-end=\"1102\"\u003eWater-level indicator\u003c\/li\u003e\n\u003cli data-section-id=\"i9ydxt\" data-start=\"1103\" data-end=\"1139\"\u003eEasy operation and low maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"jdk5pn\" data-start=\"1140\" data-end=\"1189\"\u003eWorking pressure of \u003cstrong data-start=\"1162\" data-end=\"1189\"\u003e1.2 kgf\/cm² (15–17 psi)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rn4hy9\" data-start=\"1190\" data-end=\"1237\"\u003eWorking pressure upgradeable up to \u003cstrong data-start=\"1227\" data-end=\"1237\"\u003e30 psi\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w4bd85\" data-start=\"1238\" data-end=\"1279\"\u003eSterilizing temperature \u003cstrong data-start=\"1264\" data-end=\"1279\"\u003e121°C–134°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yd29pd\" data-start=\"1280\" data-end=\"1300\"\u003e\u003cstrong data-start=\"1282\" data-end=\"1300\"\u003e150°C optional\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"u463r8\" data-start=\"1301\" data-end=\"1326\"\u003eHeat average \u003cstrong data-start=\"1316\" data-end=\"1326\"\u003e≤ ±1°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vjus6j\" data-start=\"1327\" data-end=\"1359\"\u003eDigital timer \u003cstrong data-start=\"1343\" data-end=\"1359\"\u003e0–99 minutes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yy4asa\" data-start=\"1360\" data-end=\"1392\"\u003eAutomatic low-water protection\u003c\/li\u003e\n\u003cli data-section-id=\"1w100rg\" data-start=\"1393\" data-end=\"1407\"\u003eSafety valve\u003c\/li\u003e\n\u003cli data-section-id=\"11w06g0\" data-start=\"1408\" data-end=\"1438\"\u003eOptional sterilization drums\u003c\/li\u003e\n\u003cli data-section-id=\"10f9b5f\" data-start=\"1439\" data-end=\"1472\"\u003eOptional IQ\/OQ\/PQ documentation\u003c\/li\u003e\n\u003cli data-section-id=\"1o18w4g\" data-start=\"1473\" data-end=\"1512\"\u003eOptional dot-matrix printer provision\u003c\/li\u003e\n\u003cli data-section-id=\"n910xo\" data-start=\"1513\" data-end=\"1550\"\u003eOptional temperature chart recorder\u003c\/li\u003e\n\u003cli data-section-id=\"1cn58mf\" data-start=\"1551\" data-end=\"1593\"\u003eOptional USB interface for data transfer\u003c\/li\u003e\n\u003cli data-section-id=\"1ci0pa\" data-start=\"1594\" data-end=\"1658\"\u003eNABL standards compliance stated in the supplied specification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"dtkzex\" dir=\"auto\" data-start=\"1665\" data-end=\"1700\"\u003eDouble-Wall \u0026amp; SS GMP Construction\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"1702\" data-end=\"1775\"\u003eThe autoclave uses \u003cstrong data-start=\"1721\" data-end=\"1749\"\u003edouble-wall construction\u003c\/strong\u003e with SS GMP construction.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"1777\" data-end=\"1814\"\u003eThe supplied specifications identify:\u003c\/p\u003e\n\u003cul data-start=\"1816\" data-end=\"1964\"\u003e\n\u003cli data-section-id=\"musyj1\" data-start=\"1816\" data-end=\"1856\"\u003e\n\u003cstrong data-start=\"1818\" data-end=\"1836\"\u003eOuter chamber:\u003c\/strong\u003e Stainless Steel 304\u003c\/li\u003e\n\u003cli data-section-id=\"63hlpl\" data-start=\"1857\" data-end=\"1884\"\u003e\n\u003cstrong data-start=\"1859\" data-end=\"1877\"\u003eInner chamber:\u003c\/strong\u003e SS 304\u003c\/li\u003e\n\u003cli data-section-id=\"xhk7cj\" data-start=\"1885\" data-end=\"1931\"\u003e\n\u003cstrong data-start=\"1887\" data-end=\"1914\"\u003eOptional inner chamber:\u003c\/strong\u003e SS 316 \/ SS 316L\u003c\/li\u003e\n\u003cli data-section-id=\"1ai9phk\" data-start=\"1932\" data-end=\"1964\"\u003e\n\u003cstrong data-start=\"1934\" data-end=\"1949\"\u003eInsulation:\u003c\/strong\u003e Air insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"1966\" data-end=\"2052\"\u003eThis configuration provides the specified double-wall construction for the sterilizer.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t6bnua\" dir=\"auto\" data-start=\"2054\" data-end=\"2089\"\u003eWing-Nut Locking With Pedal Lift\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2091\" data-end=\"2187\"\u003eThe autoclave is equipped with a \u003cstrong data-start=\"2124\" data-end=\"2151\"\u003ewing-nut locking system\u003c\/strong\u003e and \u003cstrong data-start=\"2156\" data-end=\"2186\"\u003epedal-assisted lid lifting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2189\" data-end=\"2317\"\u003eThe wing-nut locking arrangement secures the lid during operation, while the pedal lift is provided for convenient lid handling.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ghkgje\" dir=\"auto\" data-start=\"2319\" data-end=\"2343\"\u003eImmersion-Type Heater\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2345\" data-end=\"2394\"\u003eThe sterilizer uses an \u003cstrong data-start=\"2368\" data-end=\"2393\"\u003eimmersion-type heater\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2396\" data-end=\"2423\"\u003eAvailable heater loads are:\u003c\/p\u003e\n\u003cul data-start=\"2425\" data-end=\"2462\"\u003e\n\u003cli data-section-id=\"1lg6l5m\" data-start=\"2425\" data-end=\"2443\"\u003e\n\u003cstrong data-start=\"2427\" data-end=\"2435\"\u003e40L:\u003c\/strong\u003e 2.00 kW\u003c\/li\u003e\n\u003cli data-section-id=\"1idm2vk\" data-start=\"2444\" data-end=\"2462\"\u003e\n\u003cstrong data-start=\"2446\" data-end=\"2454\"\u003e80L:\u003c\/strong\u003e 4.00 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1yr449k\" dir=\"auto\" data-start=\"2796\" data-end=\"2812\"\u003eDigital Timer\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"2814\" data-end=\"2874\"\u003eThe autoclave is equipped with a digital timer ranging from:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2876\" data-end=\"2892\"\u003e\u003cstrong data-start=\"2876\" data-end=\"2892\"\u003e0–99 minutes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2894\" data-end=\"2948\"\u003eThe specified sterilization time is \u003cstrong data-start=\"2930\" data-end=\"2947\"\u003e25–30 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"2950\" data-end=\"3037\"\u003eActual cycle requirements may depend on the load and selected sterilization conditions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"14mjx9\" dir=\"auto\" data-start=\"3044\" data-end=\"3061\"\u003eSafety Features\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3063\" data-end=\"3086\"\u003eThe autoclave includes:\u003c\/p\u003e\n\u003cul data-start=\"3088\" data-end=\"3193\"\u003e\n\u003cli data-section-id=\"1w100rg\" data-start=\"3088\" data-end=\"3102\"\u003eSafety valve\u003c\/li\u003e\n\u003cli data-section-id=\"1affndq\" data-start=\"3103\" data-end=\"3123\"\u003eLow-water detector\u003c\/li\u003e\n\u003cli data-section-id=\"87e3c4\" data-start=\"3124\" data-end=\"3143\"\u003eLow-water cut-off\u003c\/li\u003e\n\u003cli data-section-id=\"ehgfmv\" data-start=\"3144\" data-end=\"3167\"\u003eWater-level indicator\u003c\/li\u003e\n\u003cli data-section-id=\"13bl0qb\" data-start=\"3168\" data-end=\"3193\"\u003eWing-nut locking system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"auto\" data-start=\"3195\" data-end=\"3249\"\u003eThese features are part of the supplied configuration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1eynukh\" dir=\"auto\" data-start=\"3251\" data-end=\"3270\"\u003eWorking Pressure\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3272\" data-end=\"3318\"\u003eThe standard working pressure is specified as:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3320\" data-end=\"3347\"\u003e\u003cstrong data-start=\"3320\" data-end=\"3347\"\u003e1.2 kgf\/cm² (15–17 psi)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3349\" data-end=\"3388\"\u003eThe supplied specification also states:\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3390\" data-end=\"3440\"\u003e\u003cstrong data-start=\"3390\" data-end=\"3440\"\u003eWorking pressure can be upgraded up to 30 PSI.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\" data-start=\"3442\" data-end=\"3509\"\u003eThe exact upgraded configuration should be confirmed when ordering.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n50ff3\" dir=\"auto\" data-start=\"3516\" data-end=\"3535\"\u003eOptional Features\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3537\" data-end=\"3619\"\u003eSeveral additional features are available according to the supplied specification.\u003c\/p\u003e\n\u003ch3 data-section-id=\"rc3fbn\" dir=\"auto\" data-start=\"3621\" data-end=\"3647\"\u003eIQ\/OQ\/PQ Documentation\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3649\" data-end=\"3807\"\u003e\u003cstrong data-start=\"3649\" data-end=\"3675\"\u003eIQ\/OQ\/PQ documentation\u003c\/strong\u003e is available as an optional feature for facilities requiring installation, operational and performance qualification documentation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hb5gg9\" dir=\"auto\" data-start=\"3809\" data-end=\"3831\"\u003eDot-Matrix Printer\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3833\" data-end=\"3925\"\u003eThe autoclave has a provision for attaching a \u003cstrong data-start=\"3879\" data-end=\"3901\"\u003edot-matrix printer\u003c\/strong\u003e as an optional feature.\u003c\/p\u003e\n\u003ch3 data-section-id=\"9vy998\" dir=\"auto\" data-start=\"3927\" data-end=\"3957\"\u003eTemperature Chart Recorder\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"3959\" data-end=\"4031\"\u003eA \u003cstrong data-start=\"3961\" data-end=\"3991\"\u003etemperature chart recorder\u003c\/strong\u003e can be added for temperature recording.\u003c\/p\u003e\n\u003ch3 data-section-id=\"13ij849\" dir=\"auto\" data-start=\"4033\" data-end=\"4054\"\u003eUSB Data Transfer\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4056\" data-end=\"4117\"\u003eAn optional \u003cstrong data-start=\"4068\" data-end=\"4085\"\u003eUSB interface\u003c\/strong\u003e is available for data transfer.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1googio\" dir=\"auto\" data-start=\"4119\" data-end=\"4142\"\u003eSterilization Drums\u003c\/h3\u003e\n\u003cp dir=\"auto\" data-start=\"4144\" data-end=\"4224\"\u003eSterilization drums can be supplied as an optional accessory at additional cost.\u003c\/p\u003e\n\u003ch3 data-section-id=\"l7p3ua\" dir=\"auto\" data-start=\"4231\" data-end=\"4265\"\u003eModel \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cdiv dir=\"auto\" class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"4267\" data-end=\"5196\" dir=\"auto\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"4267\" data-end=\"4306\"\u003e\n\u003ctr data-start=\"4267\" data-end=\"4306\"\u003e\n\u003cth data-start=\"4267\" data-end=\"4283\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"4283\" data-end=\"4294\" data-col-size=\"md\" class=\"last:pe-10\"\u003e40 Liter\u003c\/th\u003e\n\u003cth data-start=\"4294\" data-end=\"4306\" data-col-size=\"sm\" class=\"last:pe-10\"\u003e80 Liter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4323\" data-end=\"5196\"\u003e\n\u003ctr data-start=\"4323\" data-end=\"4363\"\u003e\n\u003ctd data-start=\"4323\" data-end=\"4348\" data-col-size=\"sm\"\u003eInternal Tank Capacity\u003c\/td\u003e\n\u003ctd data-start=\"4348\" data-end=\"4355\" data-col-size=\"md\"\u003e40 L\u003c\/td\u003e\n\u003ctd data-start=\"4355\" data-end=\"4363\" data-col-size=\"sm\"\u003e80 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4364\" data-end=\"4399\"\u003e\n\u003ctd data-start=\"4364\" data-end=\"4378\" data-col-size=\"sm\"\u003eHeater Load\u003c\/td\u003e\n\u003ctd data-start=\"4378\" data-end=\"4388\" data-col-size=\"md\"\u003e2.00 kW\u003c\/td\u003e\n\u003ctd data-start=\"4388\" data-end=\"4399\" data-col-size=\"sm\"\u003e4.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4400\" data-end=\"4451\"\u003e\n\u003ctd data-start=\"4400\" data-end=\"4420\" data-col-size=\"sm\"\u003eChamber Dimension\u003c\/td\u003e\n\u003ctd data-start=\"4420\" data-end=\"4435\" data-col-size=\"md\"\u003e300 × 550 mm\u003c\/td\u003e\n\u003ctd data-start=\"4435\" data-end=\"4451\" data-col-size=\"sm\"\u003e400 × 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4452\" data-end=\"4528\"\u003e\n\u003ctd data-start=\"4452\" data-end=\"4471\" data-col-size=\"sm\"\u003eWorking Pressure\u003c\/td\u003e\n\u003ctd data-start=\"4471\" data-end=\"4497\" data-col-size=\"md\"\u003e1.2 kgf\/cm² (15–17 psi)\u003c\/td\u003e\n\u003ctd data-start=\"4497\" data-end=\"4528\" data-col-size=\"sm\"\u003eSame specification supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4529\" data-end=\"4598\"\u003e\n\u003ctd data-start=\"4529\" data-end=\"4555\" data-col-size=\"sm\"\u003eSterilizing Temperature\u003c\/td\u003e\n\u003ctd data-start=\"4555\" data-end=\"4567\" data-col-size=\"md\"\u003e121–134°C\u003c\/td\u003e\n\u003ctd data-start=\"4567\" data-end=\"4598\" data-col-size=\"sm\"\u003eSame specification supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4599\" data-end=\"4639\"\u003e\n\u003ctd data-start=\"4599\" data-end=\"4622\" data-col-size=\"sm\"\u003eOptional Temperature\u003c\/td\u003e\n\u003ctd data-start=\"4622\" data-end=\"4630\" data-col-size=\"md\"\u003e150°C\u003c\/td\u003e\n\u003ctd data-start=\"4630\" data-end=\"4639\" data-col-size=\"sm\"\u003e150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4640\" data-end=\"4674\"\u003e\n\u003ctd data-start=\"4640\" data-end=\"4655\" data-col-size=\"sm\"\u003eHeat Average\u003c\/td\u003e\n\u003ctd data-start=\"4655\" data-end=\"4664\" data-col-size=\"md\"\u003e≤ ±1°C\u003c\/td\u003e\n\u003ctd data-start=\"4664\" data-end=\"4674\" data-col-size=\"sm\"\u003e≤ ±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4675\" data-end=\"4721\"\u003e\n\u003ctd data-start=\"4675\" data-end=\"4696\" data-col-size=\"sm\"\u003eSterilization Time\u003c\/td\u003e\n\u003ctd data-start=\"4696\" data-end=\"4708\" data-col-size=\"md\"\u003e25–30 min\u003c\/td\u003e\n\u003ctd data-start=\"4708\" data-end=\"4721\" data-col-size=\"sm\"\u003e25–30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4722\" data-end=\"4761\"\u003e\n\u003ctd data-start=\"4722\" data-end=\"4738\" data-col-size=\"sm\"\u003eDigital Timer\u003c\/td\u003e\n\u003ctd data-start=\"4738\" data-end=\"4749\" data-col-size=\"md\"\u003e0–99 min\u003c\/td\u003e\n\u003ctd data-start=\"4749\" data-end=\"4761\" data-col-size=\"sm\"\u003e0–99 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4762\" data-end=\"4824\"\u003e\n\u003ctd data-start=\"4762\" data-end=\"4777\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-start=\"4777\" data-end=\"4800\" data-col-size=\"md\"\u003eDouble wall \u0026amp; SS GMP\u003c\/td\u003e\n\u003ctd data-start=\"4800\" data-end=\"4824\" data-col-size=\"sm\"\u003eDouble wall \u0026amp; SS GMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4825\" data-end=\"4860\"\u003e\n\u003ctd data-start=\"4825\" data-end=\"4841\" data-col-size=\"sm\"\u003eOuter Chamber\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4841\" data-end=\"4850\"\u003eSS 304\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"4850\" data-end=\"4860\"\u003eSS 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4861\" data-end=\"4896\"\u003e\n\u003ctd data-start=\"4861\" data-end=\"4877\" data-col-size=\"sm\"\u003eInner Chamber\u003c\/td\u003e\n\u003ctd data-start=\"4877\" data-end=\"4886\" data-col-size=\"md\"\u003eSS 304\u003c\/td\u003e\n\u003ctd data-start=\"4886\" data-end=\"4896\" data-col-size=\"sm\"\u003eSS 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4897\" data-end=\"4961\"\u003e\n\u003ctd data-start=\"4897\" data-end=\"4922\" data-col-size=\"sm\"\u003eOptional Inner Chamber\u003c\/td\u003e\n\u003ctd data-start=\"4922\" data-end=\"4941\" data-col-size=\"md\"\u003eSS 316 \/ SS 316L\u003c\/td\u003e\n\u003ctd data-start=\"4941\" data-end=\"4961\" data-col-size=\"sm\"\u003eSS 316 \/ SS 316L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4962\" data-end=\"5010\"\u003e\n\u003ctd data-start=\"4962\" data-end=\"4975\" data-col-size=\"sm\"\u003eInsulation\u003c\/td\u003e\n\u003ctd data-start=\"4975\" data-end=\"4992\" data-col-size=\"md\"\u003eAir insulation\u003c\/td\u003e\n\u003ctd data-start=\"4992\" data-end=\"5010\" data-col-size=\"sm\"\u003eAir insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5011\" data-end=\"5056\"\u003e\n\u003ctd data-start=\"5011\" data-end=\"5037\" data-col-size=\"sm\"\u003eWater Filling \u0026amp; Removal\u003c\/td\u003e\n\u003ctd data-start=\"5037\" data-end=\"5046\" data-col-size=\"md\"\u003eManual\u003c\/td\u003e\n\u003ctd data-start=\"5046\" data-end=\"5056\" data-col-size=\"sm\"\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5057\" data-end=\"5151\"\u003e\n\u003ctd data-start=\"5057\" data-end=\"5075\" data-col-size=\"sm\"\u003eSafety Features\u003c\/td\u003e\n\u003ctd data-start=\"5075\" data-end=\"5120\" data-col-size=\"md\"\u003eSafety valve, low-water detector \u0026amp; cut-off\u003c\/td\u003e\n\u003ctd data-start=\"5120\" data-end=\"5151\" data-col-size=\"sm\"\u003eSame specification supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5152\" data-end=\"5196\"\u003e\n\u003ctd data-start=\"5152\" data-end=\"5167\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"5167\" data-end=\"5181\" data-col-size=\"md\"\u003e220V \/ 440V\u003c\/td\u003e\n\u003ctd data-start=\"5181\" data-end=\"5196\" data-col-size=\"sm\"\u003e220V \/ 440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003ch3\u003eProduct Disclaimer\u003c\/h3\u003e\n\u003cp\u003eSpecifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"APS","offers":[{"title":"Default Title","offer_id":53399192862901,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0680\/7833\/8229\/files\/Vertical-Wing-Nut-Locking-Autoclave-40L-_-80L-APS.jpg?v=1790684210","url":"https:\/\/healthyantrastore.com\/products\/vertical-autoclave-wing-nut-locking-double-wall","provider":"Health Yantra Store","version":"1.0","type":"link"}