The APS Steam Sterilizer Horizontal Cylindrical is a heavy-duty horizontal autoclave designed for bulk sterilization applications in hospitals, laboratories, and other facilities where reliable steam sterilization and dryness of sterilized loads are important. The cylindrical, triple-walled construction combines an SS 304 inner chamber, jacket, boiler and outer jacket cover with a sturdy mild-steel support stand.

The sterilizer uses a separate steam boiler positioned below the main chamber, along with pressure control, low-water protection, vacuum breaking and automatic cycle timing features. Standard and customized models can be manufactured according to customer requirements.

βœ… Key Features

  • Horizontal cylindrical, triple-walled construction
  • Heavy-duty M.S. square stand with painted finish
  • Inner chamber, door lid, jacket, boiler and outer jacket cover in SS 304
  • Separate steam boiler located below the main chamber
  • Pressure locking system prevents door opening while steam remains inside
  • Single or double hinged door options
  • Manual radial locking system with nickel-coated mild-steel construction
  • Energy-efficient industrial-grade heaters
  • High-grade fiber/mineral glass wool thermal insulation
  • Jacket pressure gauge and chamber compound gauge
  • Spring-loaded safety valve and steam release valve
  • Automatic vacuum breaker
  • Automatic pressure control switch
  • Automatic low-water-level heater cut-off
  • Digital PID temperature indicator and controller
  • Automatic digital minute timer
  • Automatic cycle-end heater shut-off with alarm
  • Four-position manually operated multiport valve
  • High-tensile jointless silicone door gasket
  • Integrated gasket groove for sealing
  • Stainless-steel baffle plate for steam distribution
  • Standard and customized configurations available

Triple-Walled Horizontal Construction

The APS horizontal steam sterilizer features a cylindrical triple-walled design mounted on a sturdy heavy-duty mild-steel square stand.

The supplied construction specification includes:

  • Inner chamber β€” SS 304
  • Door lid β€” SS 304
  • Jacket β€” SS 304
  • Boiler β€” SS 304
  • Outer jacket cover β€” SS 304

The space between the jacket and outer cover is insulated using high-grade fiber/mineral glass wool to help reduce heat loss.

Separate Steam Boiler

Steam is generated in a separate boiler positioned below the main sterilization chamber. This arrangement is designed for steam generation and delivery to the chamber during sterilization cycles.

The supplied specification does not state the boiler capacity or heater wattage.

Pressure Locking & Door Safety

A pressure locking system is provided to prevent the door from being opened while steam remains inside the chamber.

Depending on configuration, the sterilizer can be supplied with a single or double hinged door. The manual radial locking system is made from mild steel with a nickel-coated finish.

The system also includes a spring-loaded safety valve and steam-release valve.

Automatic Pressure & Low-Water Protection

The sterilizer incorporates multiple safety provisions:

Automatic Pressure Control

An automatic pressure control switch monitors jacket pressure. According to the supplied specification, when jacket steam pressure reaches 18–20 psi, the electrical supply to the heater is automatically cut off.

Low-Water Cut-Off

An automatic low-water-level cut-off device is provided to protect the heating element when the water level becomes insufficient.

Automatic Vacuum Breaker

An automatic vacuum breaker is included to break vacuum formation that may occur because of steam condensation.

Digital PID Temperature Controller

The sterilizer is equipped with a digital PID temperature indicator/controller with an LED display.

The controller displays:

  • Set value
  • Process value

An integrated digital minute timer automatically starts when the selected/desired temperature is reached.

At the completion of the programmed time:

  • Heaters switch off automatically
  • A cycle-end alarm is activated

This provides automatic timing and termination of the heating cycle according to the programmed settings.

Four-Position Multiport Valve

A manually operated four-position multiport valve is provided for controlling different steam functions, including:

  • Steam injection into the chamber
  • Dry sterilization
  • Steam exhaust

The exact valve operating sequence should be confirmed with the supplied operating manual for the selected configuration.

Silicone Door Gasket

A high-tensile, jointless silicone gasket is used to provide sealing between the chamber and door.

The gasket is seated inside an integrated groove to support proper sealing and minimize steam leakage during operation.

Stainless-Steel Baffle Plate

An SS baffle plate is incorporated for steam distribution. It is intended to help distribute steam effectively and prevent direct steam impact on the sterilized load.

Technical Specifications

Specification Details
Product Type Horizontal Steam Sterilizer
Design Cylindrical, triple-walled
Orientation Horizontal
Stand Heavy M.S. square stand, duly painted
Inner Chamber Material SS 304
Door Lid Material SS 304
Jacket Material SS 304
Boiler Material SS 304
Outer Jacket Cover SS 304
Steam Generation Separate boiler below main body
Door Configuration Single / Double hinged
Door Locking Manual radial locking system
Pressure Lock Provided
Heater Industrial-grade energy-efficient heaters
Insulation Fiber/mineral glass wool
Jacket Pressure Monitoring Pressure gauge
Chamber Pressure Monitoring Compound gauge
Safety Valve Spring-loaded
Steam Release Provided
Vacuum Protection Automatic vacuum breaker
Pressure Control Automatic pressure control switch
Pressure Cut-Off 18–20 psi jacket pressure, as supplied
Low-Water Protection Automatic low-water-level cut-off
Temperature Controller Digital PID
Display LED
Timer Automatic digital minute timer
Cycle Completion Automatic heater shut-off + alarm
Multiport Valve Manual, 4-position
Door Gasket High-tensile jointless silicone
Steam Distribution SS baffle plate
Construction Standard and customized models available

Β 

Product Disclaimer

Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.

Frequently Asked Questions

What is the APS Horizontal Steam Sterilizer?
It is a horizontal cylindrical steam sterilizer designed for bulk steam sterilization applications in hospitals, laboratories and similar facilities.
What type of construction does the sterilizer have?
It uses a triple-walled cylindrical construction mounted on a heavy-duty mild-steel square stand.
What material is used for the main sterilizer components?
The supplied specification states that the inner chamber, door lid, jacket, boiler and outer jacket cover are made from SS 304.
How is steam generated?
Steam is generated in a separate boiler located below the main sterilization chamber.
Does the sterilizer have pressure protection?
Yes. It includes a pressure locking system, pressure gauges, spring-loaded safety valve, steam release valve and automatic pressure control.
What happens when jacket pressure reaches 18–20 psi?
According to the supplied specification, the automatic pressure control switch cuts off the electrical supply to the heater when jacket pressure reaches approximately 18–20 psi.
What is the function of the vacuum breaker?
The automatic vacuum breaker is designed to break vacuum that may form because of steam condensation.
Does it have low-water protection?
Yes. An automatic low-water-level cut-off device is provided to protect the heating element.
Is the door sealed against steam leakage?
A high-tensile jointless silicone gasket seated in an integrated groove is provided for sealing.
Can the sterilizer be customized?
Yes. The supplied description states that both standard and customized models can be manufactured according to customer requirements.

Compare products