Skip to content
Partial Cash On Delivery Available | Buy Now On EMI | Free Shipping
💳 Partial COD • 🔄 Easy EMI • 🚚 Free Delivery

Medtronic ACT Plus Automated Coagulation Timer System

by ACT
Original price Rs. 0.00 - Original price Rs. 0.00
Original price
Rs. 0.00
Rs. 0.00 - Rs. 0.00
Current price Rs. 0.00
Contact For Price
Contact For Price
GST Invoice
Free Shipping
7 Days Replacement
Biomedical Support

Ask Quotation

The Refurbished Medtronic ACT Plus Automated Coagulation Timer System is a portable, microprocessor-controlled point-of-care coagulation testing device designed to measure Activated Clotting Time (ACT) in fresh or citrated whole-blood samples.

The system is intended for monitoring high-dose heparin anticoagulation during procedures where rapid coagulation assessment is required. Its automated clot-detection technology uses a photo-optical system to identify fibrin clot formation, providing objective ACT measurement through compatible test cartridges.

The ACT Plus supports multiple cartridge types, including High-Range ACT (HR-ACT), Low-Range ACT (LR-ACT), heparinase, and recalcified tests. Dual-channel testing allows applicable tests to be performed through the system's cartridge-based workflow.

With digital displays, internal data storage, and external connectivity, the system can support patient and quality-control data tracking in professional healthcare environments.

As a refurbished coagulation timer, the ACT Plus can provide a cost-effective solution for hospitals and procedure areas requiring point-of-care ACT testing. Exact cartridge compatibility, software, accessories, calibration status, and device condition should be confirmed for the individual unit.

✅ Key Features

  • Automated Coagulation Testing: Microprocessor-controlled system for point-of-care ACT measurement.
  • Activated Clotting Time (ACT): Measures ACT in fresh or citrated whole-blood samples.
  • High-Dose Heparin Monitoring: Designed for monitoring anticoagulation during procedures requiring high-dose heparin.
  • Dual-Channel Testing: Uses dual-channel test cartridges for applicable testing workflows.
  • Photo-Optical Clot Detection: Detects clot formation by measuring the slowed movement of a plunger as fibrin forms.
  • HR-ACT Testing: Supports High-Range ACT cartridges.
  • LR-ACT Testing: Supports Low-Range ACT cartridges.
  • Heparinase Testing: Supports heparinase-based testing.
  • Recalcified Testing: Supports recalcified test cartridges.
  • Digital Display: Provides digital presentation of test results and device information.
  • Internal Data Storage: Stores patient and testing information.
  • External Connectivity: Supports data transfer and tracking applications where configured.
  • Portable Design: Suitable for point-of-care testing in procedural and critical-care environments.
  • Refurbished & Cost-Effective: Provides a potentially economical alternative to acquiring new coagulation testing equipment.

How the ACT Plus Detects Clot Formation

The ACT Plus uses a photo-optical clot-detection system. During testing, the sample is processed through a compatible cartridge. As coagulation occurs and a fibrin clot forms, the movement of the cartridge's plunger slows.

The system detects this change automatically and determines the corresponding Activated Clotting Time (ACT).

Test Cartridge Options

The system supports multiple test types designed for different coagulation-testing requirements:

HR-ACT

High-Range Activated Clotting Time testing for applications requiring higher ACT measurement ranges.

LR-ACT

Low-Range Activated Clotting Time testing for applicable lower-range coagulation measurements.

Data Management

The ACT Plus includes features intended to support clinical and quality-control documentation:

  • Digital test-result display
  • Built-in data storage
  • Patient data tracking
  • Quality-control tracking
  • External connectivity
  • Data transfer capabilities where configured

Technical Specifications

Specification Details
Product Medtronic ACT Plus Automated Coagulation Timer System
Condition Refurbished
Device Type Point-of-Care Coagulation Analyzer
Test Activated Clotting Time (ACT)
Sample Type Fresh or citrated whole blood
Primary Use High-dose heparin anticoagulation monitoring
Testing Channels Dual-channel
Detection Method Photo-optical clot detection
HR-ACT Supported
LR-ACT Supported
Heparinase Test Supported
Recalcified Test Supported
Display Digital
Data Storage Built-in
External Connectivity Supported
Patient Data Tracking Supported
Quality Control Tracking Supported
Primary Applications Cardiovascular, vascular, critical care and procedural settings

 

Product Disclaimer

Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.

Frequently Asked Questions

What is the Medtronic ACT Plus Automated Coagulation Timer?
The Medtronic ACT Plus is a portable, microprocessor-controlled point-of-care coagulation testing system used to measure Activated Clotting Time in whole-blood samples.
What does refurbished Medtronic ACT Plus mean?
A refurbished ACT Plus is a previously used device that has undergone inspection and servicing as applicable before resale. The exact refurbishment process and condition may vary by individual unit.
What does the ACT Plus measure?
The system measures Activated Clotting Time (ACT) in fresh or citrated whole-blood samples.
What is the ACT Plus primarily used for?
It is designed for monitoring high-dose heparin anticoagulation in clinical procedures and critical-care applications.
What test cartridges are compatible with the ACT Plus?
The supplied information identifies HR-ACT, LR-ACT, heparinase, and recalcified test cartridge options.
What is the purpose of a heparinase test?
Heparinase testing can help evaluate coagulation results in relation to the effect of heparin in applicable clinical testing workflows.
Does the ACT Plus support quality-control tracking?
Yes. The supplied information identifies data-management capabilities for patient and quality-control tracking.
How does the ACT Plus detect a blood clot?
The system uses a photo-optical detection method that detects the slowed movement of a plunger as a fibrin clot forms in the test cartridge.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare