India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
The Refurbished Dräger Babylog 8000 Plus is a specialized neonatal and pediatric ventilator designed for hospital and intensive-care applications. Its continuous-flow, pressure-limited and time-cycled operating principle supports conventional ventilation as well as high-frequency ventilation (HFV).
The unit is designed for neonatal and pediatric respiratory support and provides adjustable inspiratory and expiratory times, inspiratory flow, oxygen concentration, and airway pressure. The white housing configuration gives the equipment a clean clinical appearance while maintaining its portable installation-grade design.
The Babylog 8000 Plus supports conventional neonatal and pediatric ventilation using:
Intermittent mandatory ventilation and intermittent positive-pressure ventilation provide mechanically delivered respiratory support according to the configured ventilation parameters.
Continuous positive airway pressure supports spontaneously breathing patients by maintaining positive airway pressure throughout the respiratory cycle.
The Babylog 8000 Plus also supports high-frequency ventilation, providing additional respiratory-support options for neonatal and pediatric critical-care applications.
Available high-frequency configurations include:
The exact mode and settings should be selected according to the patient's clinical requirements and the configuration of the individual ventilator.
The ventilator uses a continuous-flow, pressure-limited and time-cycled control principle.
This operating approach allows clinicians to configure respiratory timing and pressure-related parameters for neonatal and pediatric ventilation.
The Babylog 8000 Plus provides broad timing adjustment ranges:
These settings allow ventilation timing to be configured according to patient requirements.
The specified inspiratory-flow range is:
1–30 L/min
The appropriate flow setting depends on the selected ventilation mode, patient category, and clinical requirements.
The ventilator supports an oxygen concentration range of:
21%–100% O₂ by volume
This provides adjustable oxygen delivery for neonatal and pediatric respiratory-support applications.
The supplied specification indicates a maximum peak pressure of:
Up to 99 mbar
Actual operating pressure should be configured according to the selected ventilation mode and clinical requirements.
| Specification | Details |
|---|---|
| Brand | Dräger |
| Model | Babylog 8000 Plus |
| Condition | Refurbished |
| Color | White |
| Application | Hospital / ICU |
| Patient Category | Neonatal & Pediatric |
| Body Material | Aluminum body configuration |
| Design | Portable installation-grade |
| Control Principle | Continuous flow, pressure-limited, time-cycled |
| Conventional Modes | IMV/IPPV, CPAP |
| High-Frequency Modes | CPAP + HFV, IMV + HFV |
| Inspiratory Time | 0.1–2 seconds |
| Expiratory Time | 0.2–30 seconds |
| Inspiratory Flow | 1–30 L/min |
| O₂ Concentration | 21–100% by volume |
| Peak Pressure | Up to 99 mbar |
| Height | Approx. 690 mm |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.