The Refurbished Dräger Evita 2 Dura ICU Ventilator is an intensive-care mechanical ventilator designed to provide respiratory support for adult, pediatric, and neonatal patients. It supports both invasive and non-invasive ventilation (NIV) and is suitable for a range of critical-care and hospital respiratory applications.

The Evita 2 Dura combines a ventilator base with an integrated high-resolution color display that presents real-time respiratory curves and monitored values. Depending on patient category and configuration, the ventilator supports tidal volumes from approximately 20 to 1,500 mL, with adult configurations extending up to approximately 2.0 L.

Its ventilation capabilities include IPPV, SIMV, MMV, and AutoFlow options, providing different approaches to controlled and assisted mechanical ventilation.

A typical refurbished package may include the main ventilator unit, medical trolley, color display, exhalation valve, flow sensor, breathing circuit hoses, power cable, battery, and O₂/air pipeline hoses. An air compressor or external battery backup may be supplied depending on the specific configuration.

✅ Key Features

  • ICU Ventilator: Designed for intensive-care respiratory support.
  • Multi-Patient Capability: Supports adult, pediatric, and neonatal patients.
  • Invasive & NIV Support: Provides invasive and non-invasive ventilation options.
  • Multiple Ventilation Modes: Includes IPPV, SIMV, MMV, and AutoFlow options.
  • Broad Tidal Volume Range: Approximately 20–1,500 mL, with adult configurations up to approximately 2.0 L.
  • Wide Respiratory Rate Range: Approximately 0–300 breaths/min, according to the supplied specifications.
  • High-Resolution Color Display: Shows real-time respiratory curves and monitored parameters.
  • Trolley Mounted: Typical package includes a wheeled medical cart for mobility.
  • Exhalation Valve & Flow Sensor: Included in the stated package configuration.
  • Breathing Circuit Support: Reusable or test breathing circuit hoses may be supplied.
  • Battery Operation: Operational battery included in the stated standard package.
  • Pipeline Connectivity: O₂ and air pipeline hoses included in the stated package.
  • Optional Compressor: An air compressor may be available depending on configuration.
  • External Battery Option: Additional external battery backup may be available depending on configuration.
  • Refurbished & Cost-Effective: A practical option for healthcare facilities seeking ICU ventilation equipment.

Ventilation Modes

IPPV

Intermittent Positive Pressure Ventilation (IPPV) provides controlled positive-pressure mechanical ventilation for patients requiring mandatory respiratory support.

SIMV

Synchronized Intermittent Mandatory Ventilation (SIMV) combines mandatory mechanical breaths with opportunities for spontaneous breathing.

MMV

Mandatory Minute Ventilation (MMV) is an assisted ventilation strategy designed around maintaining the required minute ventilation while allowing spontaneous breathing.

AutoFlow

AutoFlow provides an adaptive approach to volume-targeted ventilation, with the exact functionality depending on the device configuration.

NIV

The Evita 2 Dura supports non-invasive ventilation (NIV) for applicable patients and clinical situations.

Display & Monitoring

The integrated high-resolution color display provides real-time visualization of:

  • Respiratory curves
  • Monitored values
  • Ventilation parameters
  • Patient respiratory information

This graphical interface allows clinical personnel to observe ventilator and patient respiratory data during operation.

Technical Specifications

Specification Details
Product Dräger Evita 2 Dura ICU Ventilator
Condition Refurbished
Device Type Intensive Care Ventilator
Patient Types Adult, Pediatric, Neonatal
Ventilation Invasive & Non-Invasive (NIV)
Tidal Volume Approximately 20–1,500 mL*
Adult Tidal Volume Up to approximately 2.0 L*
Respiratory Rate Approximately 0–300 bpm
Display High-resolution integrated color screen
Display Information Real-time curves and monitored values
IPPV Yes
SIMV Yes
MMV Yes
AutoFlow Available/configuration dependent
Exhalation Valve Included in stated package
Flow Sensor Included in stated package
Breathing Circuit Reusable or test hoses*
Trolley Wheeled medical cart
Battery Operational battery
Power Power cable included
O₂ Connection Pipeline hose included
Air Connection Pipeline hose included
Air Compressor Optional/configuration dependent
External Battery Optional/configuration dependent
Primary Application ICU & Critical Care

 

Product Disclaimer

Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.

Frequently Asked Questions

What is the Dräger Evita 2 Dura ventilator?
The Dräger Evita 2 Dura is an intensive-care mechanical ventilator designed for adult, pediatric, and neonatal respiratory support.
What does refurbished Dräger Evita 2 Dura mean?
A refurbished Evita 2 Dura is a previously used ventilator that has undergone inspection and servicing as applicable before resale. The exact refurbishment process and condition may vary by individual unit.
What is the tidal-volume range of the Evita 2 Dura?
The supplied specifications indicate approximately 20–1,500 mL, with adult configurations extending up to approximately 2.0 L.
Does the Evita 2 Dura support NIV?
Yes. The supplied information identifies both invasive ventilation and non-invasive ventilation (NIV).
What ventilation modes are available?
The listed ventilation modes include IPPV, SIMV, MMV, and AutoFlow, with exact functionality depending on configuration.
What is IPPV ventilation?
IPPV stands for Intermittent Positive Pressure Ventilation and provides controlled positive-pressure mechanical ventilation.
What is SIMV on the Evita 2 Dura?
SIMV, or Synchronized Intermittent Mandatory Ventilation, combines mandatory ventilator breaths with opportunities for spontaneous breathing.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare