The Dräger Evita 4 is an advanced intensive care mechanical ventilator designed to provide respiratory support for adult, pediatric, and neonatal patients. Its modular architecture, full-color display, and microprocessor-controlled ventilation platform allow it to support a broad range of invasive and spontaneous breathing applications in critical-care environments.
This refurbished Dräger Evita 4 ventilator offers multiple ventilation strategies, including IPPV/CPPV, SIMV, MMV, BIPAP/APRV, CPAP and assisted spontaneous breathing. Advanced functions such as AutoFlow, apnea ventilation, intrinsic PEEP measurement, compliance monitoring and MEDIBUS connectivity support comprehensive clinical ventilation management.
| Mode | Description |
|---|---|
| IPPV / CPPV | Intermittent or continuous positive pressure ventilation, with optional AutoFlow |
| SIMV | Synchronized intermittent mandatory ventilation using volume- or pressure-controlled breaths |
| MMV | Mandatory Minute Volume ventilation |
| BIPAP / APRV | Biphasic positive airway pressure / airway pressure release ventilation supporting spontaneous breathing |
| SB | Spontaneous breathing |
| CPAP | Continuous positive airway pressure |
| ASB | Assisted spontaneous breathing / pressure support |
The AutoFlow function automatically regulates inspiratory flow during volume-controlled ventilation.
This allows the ventilator to adjust inspiratory flow according to the selected ventilation requirements while maintaining the intended volume-controlled ventilation strategy.
The Evita 4 provides real-time visualization and measurement of important respiratory parameters.
The system can display:
The supplied specifications include monitoring of:
Special functions include:
If spontaneous breathing stops, the ventilator can automatically switch to mandatory ventilation as an apnea backup function.
The gas-supply system can automatically shift to an alternative functional gas input when a loss of line pressure is detected.
These functions are intended to provide additional operational safety during mechanical ventilation.
The Dräger Evita 4 supports the MEDIBUS protocol for external data exchange.
Depending on the installed configuration and connected equipment, this can support:
| Specification | Details |
|---|---|
| Manufacturer | Dräger |
| Model | Evita 4 |
| Equipment Type | ICU mechanical ventilator |
| Condition | Refurbished |
| Patient Population | Adult, pediatric & neonatal |
| Display | Full-color screen |
| Control System | Microprocessor-controlled |
| IPPV / CPPV | Yes |
| AutoFlow | Available |
| SIMV | Yes |
| MMV | Yes |
| BIPAP / APRV | Yes |
| SB / CPAP / ASB | Yes |
| Waveforms | Pressure, flow & volume |
| Minute Volume Monitoring | Expiratory MV |
| Tidal Volume Monitoring | Yes |
| O₂ Monitoring | Yes |
| Gas Temperature Monitoring | Yes |
| Compliance Measurement | Yes |
| Auto-PEEP | Intrinsic PEEP calculation |
| Inspiratory Hold | Yes |
| Expiratory Hold | Yes |
| Apnea Ventilation | Automatic backup |
| Gas Supply Logic | Automatic alternative gas-input selection |
| Data Connectivity | MEDIBUS |
| Primary Application | Intensive care respiratory support |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.