India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
India's Fastest Growing Healthcare Device E-Store
The Dräger Oxylog 2000 is a time-cycled, volume-constant emergency and transport ventilator designed for adult and pediatric patients. This refurbished ventilator is intended for professional respiratory support during pre-hospital emergency care, intra-hospital patient movement, and road or air transport.
The Oxylog 2000 provides controlled and synchronized ventilation through IPPV, SIPPV and SIMV, along with CPAP for spontaneous breathing. It also incorporates adjustable PEEP, oxygen concentration settings, airway-pressure monitoring, expiratory minute-volume monitoring, and built-in alarms for important operating conditions.
| Mode | Description |
|---|---|
| IPPV | Intermittent Positive Pressure Ventilation for controlled mechanical ventilation |
| SIPPV | Synchronized Intermittent Positive Pressure Ventilation |
| SIMV | Synchronized Intermittent Mandatory Ventilation |
| CPAP | Continuous Positive Airway Pressure for spontaneous breathing |
The Oxylog 2000 provides an adjustable tidal-volume range of approximately 100 mL to 1,500 mL, while some setups or versions may support volumes up to 2,000 mL.
Oxygen concentration can be configured to approximately 60 volume % or 100 volume %, depending on the particular version/setup.
Because this is refurbished equipment, the exact available range should be verified against the specific unit before purchase.
The ventilator incorporates an adjustable PEEP valve, with the supplied specifications indicating a typical range of 0–15 mbar.
The inspiratory-to-expiratory ratio can be adjusted approximately from:
The Oxylog 2000 provides basic monitoring and surveillance functions intended for emergency and transport ventilation.
Airway pressure is monitored using:
The ventilator tracks expiratory minute volume (MV) to provide information about delivered respiratory ventilation.
The built-in surveillance system provides alerts related to:
| Specification | Details |
|---|---|
| Manufacturer | Dräger |
| Model | Oxylog 2000 |
| Equipment Type | Emergency & transport ventilator |
| Condition | Refurbished |
| Ventilation Type | Time-cycled, volume-constant |
| Patient Population | Adult & pediatric |
| IPPV | Yes |
| SIPPV | Yes |
| SIMV | Yes |
| CPAP | Yes |
| Tidal Volume | 100–1,500 mL |
| Maximum Tidal Volume | Up to 2,000 mL depending on version/setup |
| Oxygen Concentration | Approx. 60% or 100% |
| PEEP | Typically 0–15 mbar |
| I:E Ratio | Approx. 1:3 to 2:1 |
| Airway Pressure Monitoring | Analog gauge + digital display |
| Minute Volume Monitoring | Expiratory MV |
| Alarms | Airway pressure, power supply, gas supply |
| Primary Applications | Pre-hospital, intra-hospital & transport |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}