The Refurbished Fisher & Paykel Airvo 2 is an active heated humidifier with an integrated flow generator designed to deliver high-flow nasal cannula (HFNC) therapy to spontaneously breathing patients. It provides warmed and humidified respiratory gases at flow rates from 2 to 60 L/min, helping deliver comfortable high-flow respiratory support in professional healthcare and home-care environments.
The Airvo 2 combines active humidification, integrated flow generation, and heated breathing-tube technology in a compact system. It supports multiple temperature settings and can receive oxygen from an external source such as an oxygen cylinder or concentrator.
The Airvo 2 is designed to provide heated and humidified high-flow respiratory gases for spontaneously breathing patients.
Its integrated flow generator allows respiratory gas flow to be delivered without requiring a separate flow generator. When supplemental oxygen is required, oxygen can be introduced from an external oxygen source.
| Mode | Flow Range |
|---|---|
| Standard Mode | 10–60 L/min |
| Junior Mode | 2–25 L/min |
| Overall Flow Range | 2–60 L/min |
The appropriate flow should be selected according to the patient's clinical requirements and the applicable interface.
The Airvo 2 uses active humidification to warm and humidify respiratory gases before they reach the patient.
Temperature settings include:
The system's humidification technology is designed to provide controlled humidity while delivering high-flow respiratory support.
The AirSpiral heated breathing tube incorporates a dual-spiral design intended to help minimize condensation within the respiratory circuit.
This is particularly useful when delivering warmed, humidified gases at high flow rates.
The Airvo 2 can operate with respiratory gas containing oxygen concentrations from approximately 21% to 100%, depending on the external oxygen supply and system configuration.
Compatible external oxygen sources can include:
The oxygen source and flow should be configured according to clinical requirements and equipment specifications.
The Airvo 2 supports a range of patient interfaces designed for high-flow respiratory therapy.
Supported interface categories include:
The specific interface required depends on the patient's condition and the intended therapy.
| Specification | Details |
|---|---|
| Product | Fisher & Paykel Airvo 2 |
| Condition | Refurbished |
| Device Type | Heated humidifier with integrated flow generator |
| Therapy | High-Flow Nasal Cannula (HFNC) |
| Patient Type | Spontaneously breathing patients |
| Flow Range | 2–60 L/min |
| Standard Mode | 10–60 L/min |
| Junior Mode | 2–25 L/min |
| Temperature Settings | 31°C / 34°C / 37°C |
| Oxygen Concentration | 21–100% |
| Oxygen Supply | External cylinder or concentrator |
| Heated Tube | AirSpiral heated tube |
| Interfaces | Optiflow nasal cannula, tracheostomy interface, mask adapter |
| Dimensions | Approx. 295 × 170 × 175 mm |
| Weight | Approx. 2.2 kg |
| Humidification | Active heated humidification |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.