Skip to content
Partial Cash On Delivery Available | Buy Now On EMI | Free Shipping
💳 Partial COD • 🔄 Easy EMI • 🚚 Free Delivery

HAMILTON-C1 Mechanical Ventilator

Original price Rs. 0.00 - Original price Rs. 0.00
Original price
Rs. 0.00
Rs. 0.00 - Rs. 0.00
Current price Rs. 0.00
Contact For Price
Contact For Price
GST Invoice
Free Shipping
7 Days Replacement
Biomedical Support

Ask Quotation

The Refurbished HAMILTON-C1 Mechanical Ventilator is a compact, high-performance ventilator designed to provide respiratory support for adult, pediatric, and neonatal patients. Its integrated high-performance turbine allows the ventilator to operate without requiring an external compressed-air source, making it well suited to a wide range of clinical environments.

The HAMILTON-C1 supports invasive ventilation, non-invasive ventilation (NIV), and high-flow oxygen therapy. Advanced ventilation technologies such as ASV® (Adaptive Support Ventilation) and INTELLiVENT®-ASV provide sophisticated options for managing changing patient respiratory requirements.

With more than 4 hours of battery backup, an integrated turbine, and a compact design, the refurbished HAMILTON-C1 is suitable for hospitals, ICUs, emergency care, and other professional respiratory-care environments.

Its monitoring and visualization capabilities include the Dynamic Lung Panel, Vent Status Panel, and IntelliSync®+, providing clinicians with graphical information about lung mechanics, patient triggering, and patient-ventilator interaction.

✅ Key Features

  • Compact Critical-Care Ventilator: Designed for adult, pediatric, and neonatal respiratory support.
  • Wide Patient Coverage: Supports pediatric patients down to approximately 3 kg and neonatal patients up to approximately 30 kg, according to the supplied configuration information.
  • Integrated Turbine: Built-in high-performance turbine eliminates the need for an external compressed-air source.
  • Extended Battery Backup: Provides more than 4 hours of battery operation under applicable conditions.
  • Multiple Ventilation Modes: Includes volume-controlled, pressure-controlled, ASV®, INTELLiVENT®-ASV, and NIV modes.
  • Invasive & Non-Invasive Ventilation: Supports both invasive ventilation and NIV.
  • Integrated High-Flow Therapy: HiFlowO₂ allows high-flow oxygen therapy without changing breathing circuits.
  • Dynamic Lung Panel: Provides real-time visualization of compliance, resistance, and patient triggering.
  • Vent Status Panel: Graphically displays the patient's dependence on mechanical ventilation.
  • IntelliSync®+: Provides real-time patient-ventilator synchronization based on pressure and flow.
  • CPR Ventilation Mode: Adapts ventilator settings and alarms for resuscitation workflows and includes an on-screen CPR timer.
  • Speak Valve Option: Supports speech and swallowing for applicable tracheostomized patients during respiratory support.
  • Humidification Control: Provides integrated control of humidification.
  • Refurbished & Cost-Effective: A practical option for healthcare facilities seeking advanced ventilation technology at a potentially lower acquisition cost.

Patient Range

The HAMILTON-C1 is designed for multiple patient categories:

Patient Category Supplied Range
Adult Supported
Pediatric Down to approximately 3 kg
Neonatal Up to approximately 30 kg

The exact patient range should be confirmed against the specific device configuration and applicable clinical setup.

Ventilation Modes

Volume-Controlled Ventilation

Provides volume-targeted mechanical ventilation for patients requiring controlled tidal-volume delivery.

Pressure-Controlled Ventilation

Provides pressure-targeted respiratory support with controlled inspiratory pressure.

ASV®

Adaptive Support Ventilation (ASV®) provides an adaptive ventilation strategy designed to adjust support according to changing patient respiratory requirements.

INTELLiVENT®-ASV

The HAMILTON-C1 can support INTELLiVENT®-ASV as an advanced automated ventilation option where appropriately configured.

Monitoring & Visualization

Dynamic Lung Panel

The Dynamic Lung Panel provides real-time graphical visualization of:

  • Lung compliance
  • Airway resistance
  • Patient triggering

This can help clinicians visualize changes in respiratory mechanics and patient interaction with the ventilator.

Vent Status Panel

The Vent Status Panel provides a graphical representation of the patient's level of dependence on mechanical ventilation, supporting assessment during respiratory care and weaning workflows.

IntelliSync®+

IntelliSync®+ provides real-time visualization and synchronization of patient respiratory effort with ventilator pressure and flow signals.

Humidification Control

Integrated humidification control allows the ventilator to interface with compatible humidification systems and manage humidification-related settings.

Technical Specifications

Specification Details
Product HAMILTON-C1 Mechanical Ventilator
Condition Refurbished
Device Type Compact Mechanical Ventilator
Patient Categories Adult, Pediatric, Neonatal
Pediatric Patient Range Down to approximately 3 kg*
Neonatal Patient Range Up to approximately 30 kg*
Ventilation Invasive & Non-Invasive
Turbine Integrated high-performance turbine
External Compressed Air Not required for turbine operation
Battery Backup More than 4 hours*
Ventilation Modes Volume Control, Pressure Control, ASV®, INTELLiVENT®-ASV, NIV
High-Flow Therapy Integrated HiFlowO₂
Dynamic Lung Panel Yes
Vent Status Panel Yes
IntelliSync®+ Yes/configuration dependent
CPR Ventilation Mode Yes
Speak Valve Optional
Humidification Control Integrated
Primary Applications ICU, Hospital, Emergency & Respiratory Care


Product Disclaimer

Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.

Frequently Asked Questions

What is the HAMILTON-C1 ventilator?
The HAMILTON-C1 is a compact mechanical ventilator designed for adult, pediatric, and neonatal patients, supporting invasive ventilation, NIV, and high-flow oxygen therapy.
What does refurbished HAMILTON-C1 mean?
A refurbished HAMILTON-C1 is a previously used ventilator that has undergone inspection and servicing as applicable before resale. The exact refurbishment process and condition may vary by individual unit.
What is the pediatric weight range?
The supplied information indicates that pediatric support extends down to approximately 3 kg.
Does the HAMILTON-C1 support neonatal patients?
Yes. The supplied information identifies neonatal support up to approximately 30 kg, depending on configuration.
Does the HAMILTON-C1 require an external compressed-air source?
The ventilator has an integrated high-performance turbine, allowing independent operation without an external compressed-air source.
How long does the HAMILTON-C1 battery last?
The supplied description specifies more than 4 hours of battery backup. Actual runtime can vary depending on ventilator settings, battery condition, and operating conditions.
What is ASV® on the HAMILTON-C1?
Adaptive Support Ventilation (ASV®) is an advanced ventilation mode designed to adapt ventilatory support according to patient respiratory requirements.

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare