The Medicaid BERA-3000 (Beragraph) is a diagnostic Brainstem Evoked Response Audiometry (BERA) system designed by Medicaid Systems for recording auditory evoked potentials and assessing objective hearing thresholds.
The system combines high-performance amplifiers, 14-bit averaging, programmable auditory stimulation, automatic masking control, and advanced waveform analysis. In addition to BERA, the system supports MLR, LLR, and P300 testing, making it suitable for a range of auditory and evoked-potential assessment applications.
The Medicaid BERA-3000 is designed to acquire and analyze small evoked-potential signals generated in response to auditory stimulation.
Its averaging and waveform-analysis capabilities are intended to support objective assessment of auditory thresholds. The system can record multiple waveforms simultaneously and provides tools for comparing responses between the left and right ears, superimposing curves, smoothing stored data, and reformatting test parameters.
The BERA-3000 incorporates high-performance amplifiers designed to acquire high-quality auditory evoked-potential signals.
Accurate signal acquisition is important in evoked-potential testing because the responses being measured can be relatively small compared with unwanted electrical and physiological signals.
The system uses 14-bit averaging for objective auditory threshold measurement.
The supplied specifications state threshold accuracy of greater than 5 dB.
This averaging capability supports the identification and analysis of auditory evoked responses during testing.
The BERA-3000 provides multiple auditory stimulation options:
The stimulation can be configured for:
The specified stimulus intensity range is:
0–120 dB
This provides flexibility for different auditory evoked-potential testing protocols.
The system includes automatic masking control.
According to the supplied information, masking intensity is automatically controlled relative to the stimulating intensity while maintaining a constant programmed difference.
This helps simplify masking-related adjustments during applicable auditory testing procedures.
The BERA-3000 supports several testing modalities:
Brainstem Evoked Response Audiometry for recording auditory evoked responses and objective hearing assessment.
Middle Latency Response testing for evaluation of middle-latency auditory responses.
Long Latency Response testing for later auditory evoked responses.
P300 cognitive evoked-potential testing for appropriate neurophysiological assessment protocols.
The system can record up to 16 waveforms and includes automatic waveform-marking capabilities.
This facilitates the organization and review of multiple responses acquired during an examination.
A split-screen display allows responses from the left and right ears to be compared.
The system also provides curve superimposition, allowing waveforms to be visually compared during analysis.
The software provides several analysis tools, including:
These functions provide flexibility when examining stored evoked-potential recordings.
The BERA-3000 is designed for Windows-based operation software.
The supplied compatibility information specifically identifies:
The software is described as user-friendly and provides the interface for acquisition, analysis, review and reporting of evoked-potential tests.
The Medicaid BERA-3000 may be used in appropriate:
The system is designed for auditory evoked-potential testing and related evoked-response examinations.
| Specification | Details |
|---|---|
| Brand | Medicaid Systems |
| Model | BERA-3000 |
| Product Name | Beragraph |
| Device Type | Brainstem Evoked Response Audiometry System |
| Amplifier | High-performance evoked-potential amplifier |
| Averaging | 14-bit |
| Threshold Accuracy | >5 dB, as specified |
| Stimulus Types | Burst, Log-in, Click |
| Polarity | Condensation, Rarefaction, Alternating |
| Stimulus Intensity | 0–120 dB |
| Masking | Automatic masking intensity control |
| Waveform Recording | Up to 16 waveforms |
| Waveform Marking | Automatic marking |
| Ear Comparison | Left/right split-screen |
| Curve Analysis | Superimposition |
| Data Processing | Smoothing filters |
| Parameter Control | Reformatting during/after testing |
| Supported Tests | BERA, MLR, LLR, P300 |
| Software | Windows-based operation software |
| Specified Windows Platforms | Windows 98 / ME / XP |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.