The Refurbished Medisys Neocare Neonatal Ventilator is a micro-controller-based, continuous-flow mechanical ventilator designed specifically for neonatal, infant, and pediatric patients. It incorporates both pressure-limiting and volume-limiting mechanisms to help protect fragile lungs from excessive airway pressure and delivered volume.
The Neocare provides a tidal-volume range of 6–300 mL, flow from 2–25 L/min, and respiratory rates from 1–150 breaths per minute, making it suitable for ventilation across a broad range of neonatal and pediatric requirements.
A 12.1-inch graphical LCD provides simultaneous visualization of pressure and flow curves. The ventilator also incorporates apnea backup ventilation, sensitive proximal flow and pressure triggering, and a servo-controlled oxygen blender with automatic sensor calibration and closed-loop feedback for controlled FiO₂ delivery.
The compact core ventilator module weighs approximately 8.2 kg and operates from 220–240 VAC, with an approximately 3-hour built-in battery backup.
The Medisys Neocare is specifically designed for:
Its low tidal-volume capability, sensitive triggering, continuous-flow architecture, and pressure/volume limiting mechanisms are designed around the requirements of ventilation in smaller and more vulnerable patients.
Clinical parameters must be selected by appropriately qualified neonatal/pediatric healthcare professionals according to patient condition and applicable clinical protocols.
The ventilator incorporates both pressure-limiting and volume-limiting mechanisms.
These systems are intended to help reduce the potential for:
The actual protective effect depends on appropriate ventilator setup, patient monitoring, clinical settings, and proper use of the equipment.
The Neocare supports multiple ventilation modes:
Provides assisted or controlled ventilation for patients requiring mandatory respiratory support.
Synchronized Intermittent Mandatory Ventilation (SIMV) and Intermittent Mandatory Ventilation (IMV) modes provide mandatory breaths while accommodating the patient's spontaneous respiratory activity according to the selected configuration.
CPAP provides continuous positive airway pressure, with backup ventilation available to provide respiratory support during apnea according to the configured system settings.
Standby mode allows the ventilator to remain ready without delivering normal active ventilation.
The Neocare uses proximal patient sensing and combines:
This sensitive triggering system is designed to detect patient respiratory efforts and support synchronized ventilator response.
For neonatal patients, where spontaneous respiratory efforts can be small, sensitive triggering can be particularly important for appropriate patient-ventilator interaction.
The ventilator incorporates a servo-controlled oxygen blender designed to provide controlled FiO₂ delivery.
The oxygen-control system includes:
This configuration is designed to help maintain accurate oxygen concentration according to the selected settings.
| Specification | Medisys Neocare |
|---|---|
| Equipment Type | Neonatal/Pediatric Ventilator |
| Condition | Refurbished |
| Control System | Micro-controller-based |
| Ventilation Type | Continuous Flow |
| Patient Category | Neonatal, Infant & Pediatric |
| Tidal Volume | 6–300 mL |
| Flow Range | 2–25 L/min |
| Respiratory Rate | 1–150 breaths/min |
| Ventilation Modes | AC, SIMV/IMV, CPAP + Backup, Standby |
| Apnea Backup | Automatic |
| Patient Triggering | Flow + Pressure |
| Patient Sensing | Proximal |
| Oxygen Control | Servo-controlled oxygen blender |
| Oxygen Calibration | Automatic sensor calibration |
| FiO₂ Control | Closed-loop feedback |
| Display | 12.1-inch Graphical LCD |
| Waveforms | Pressure & Flow Curves |
| Power Supply | 220–240 VAC |
| Battery Backup | Approx. 3 hours |
| Core Module Weight | Approx. 8.2 kg |
Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.