The Microlab ARX 199 Biochemistry Analyzer is a semi-automatic clinical chemistry analyzer designed for hospitals, diagnostic laboratories, and clinical testing facilities. It uses absorption photometry to measure biochemical parameters and supports multiple assay methods, including absorbance, end-point, kinetic, fixed-time, and differential analysis.

Featuring a blue-backlit LCD display, user-friendly software, a built-in thermal graphic printer, and memory for up to 1,000 test results with patient identification, the Microlab ARX 199 supports routine laboratory workflows. Its Peltier-controlled incubator, dual measurement system, and quality control memory provide additional functionality for clinical chemistry testing.

Key Features of Microlab ARX 199

  • Semi-Automatic Operation: Designed for biochemical testing in clinical laboratories and hospitals.

  • Absorption Photometry: Supports photometric measurement of biochemical parameters.

  • Multiple Assay Methods: ABS, end-point, kinetic, fixed-time, and differential methods.

  • Blue-Backlit LCD Display: 240 × 64-pixel display for viewing test information.

  • Patient Data Management: Allows entry and editing of patient ID, patient name, and test factors.

  • Real-Time Kinetic Graphs: Displays kinetic test graphs and supports graph editing.

  • Result Storage: Stores up to 1,000 test results with patient identification.

  • Lamp Saver Mode: Helps extend halogen lamp life.

  • Built-In Thermal Printer: 57 mm print width and 50 mm/sec printing speed.

  • Quality Control Memory: Stores the last 30 QC results.

  • Wide Voltage Input: Supports the specified 90–265 V input range for operation across varying supply voltages.

  • Compact Design: Measures approximately 40 × 32 × 16 cm.

Technical Specifications

Specification Details
Product Name Microlab ARX 199 Biochemistry Analyzer
Brand Microlab
Model ARX 199
Analyzer Type Semi-automatic biochemistry analyzer
Measurement Principle Absorption photometry
Assay Methods ABS, End Point, Kinetic, Fixed Time, Differential
Wavelength Filters 340, 405, 505, 546, 578, 630, 670 nm
Additional Filter Position 1 extra slot
Light Source 6 V/10 W halogen lamp
Detector Silicon photodiode
Display Blue-backlit LCD, 240 × 64 pixels
Temperature Control Peltier-controlled
Temperature Settings 25°C, 30°C, 37°C
Cuvette Options Removable macro, semi-micro, and micro cuvettes
Test Result Memory Up to 1,000 results with patient identification
QC Memory Last 30 QC results
Printer Built-in thermal graphic printer
Printer Width 57 mm
Printing Speed 50 mm/sec
Input Voltage 90–265 V (feature specification); 110–220 V (listed electrical specification)
Frequency 50–60 Hz
Maximum Power Consumption 80 W
Ambient Temperature 10–40°C
Dimensions 40 × 32 × 16 cm

 

Product Disclaimer

Specifications and included accessories may vary by production batch, market, or manufacturer revision. Please verify the exact configuration with the seller before purchase. This product information is intended for general product guidance and does not replace professional medical advice, diagnosis, or treatment.

Frequently Asked Questions

What is the Microlab ARX 199 Biochemistry Analyzer?
The Microlab ARX 199 is a semi-automatic biochemistry analyzer designed for clinical laboratories and hospitals.
Which assay methods does the Microlab ARX 199 support?
It supports ABS, end-point, kinetic, fixed-time, and differential methods.
Which wavelength filters are available on the Microlab ARX 199?
The listed wavelengths are 340, 405, 505, 546, 578, 630, and 670 nm, plus one extra filter slot.
What type of display does the Microlab ARX 199 have?
It features a blue-backlit LCD with a resolution of 240 × 64 pixels.
Does the Microlab ARX 199 support removable cuvettes?
Yes, it supports removable macro, semi-micro, and micro cuvettes.
How many test results can the Microlab ARX 199 store?
It can store up to 1,000 test results with patient identification.
Does the Microlab ARX 199 have a built-in printer?
Yes, it includes a thermal graphic printer with a 57 mm print width and a printing speed of 50 mm/sec.
What is the maximum power consumption of the Microlab ARX 199?
The listed maximum power consumption is 80 W.
What ambient conditions are specified for the Microlab ARX 199?
The specified ambient temperature is 10–40°C, with relative humidity of 80% or less.
What is the purpose of the lamp saver mode on the Microlab ARX 199?
The lamp saver mode is designed to help extend the life of the halogen lamp.
Which patient information can be entered using the Microlab ARX 199 software?
The software supports entering and editing patient ID, patient name, and test factors.

Compare products